Kenmore 110.9656 manual Plug into a grounded 3 prong outlet

Page 14

5.Place the inner door assembly inside the outer door assembly. To fit correctly, the inner door assembly edge fits completely inside the outer door assembly edge.

6.Reassemble the inner and outer door assemblies with the 6 screws.

Reverse the strike

1.Use a small flat-blade screwdriver to remove plug strip from the front panel dryer door opening. Slide the head of the screwdriver under the plugs, being certain not to scratch the dryer surface. Lift up.

2.Remove the strike.

3.Insert strike and plug strip on the opposite side.

A. Plug strip (cannot be seen from this angle)

B. Door strike

Reinstall the door

1.Reattach door to dryer front panel with the 4 screws.

®

A. Dryer front panel

B. Door assembly

2.Check for fingerprints on the glass. Clean glass if necessary.

3.Close door and check that it latches securely.

1.Check that all parts are now installed. If there is an extra part, go back through the steps to see which step was skipped.

2.Check that you have all of your tools.

3.Dispose of/recycle all packaging materials.

4.Check the dryer'sfinal location. Be sure the vent is not crushed or kinked.

5.Check that the dryer is level. See "Level Dryer."

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord,

Failure to follow these instructions can result in death, fire, or electrical shock.

6.Plug into a grounded 3 prong outlet. Turn on power.

7.Remove any protective film or tape remaining on the dryer.

8.Read "Dryer Use."

9.Wipe the dryer drum interior thoroughly with a damp cloth to remove any dust.

10.Select a Timed Dry heated cycle, and start the dryer. Do not select the Air Only modifier.

If the dryer will not start, check the following:

Dryer is plugged into a grounded 3 prong outlet.

Electrical supply is connected.

Household fuse is intact and tight, or circuit breaker has not tripped.

Dryer door is closed.

1f. When the dryer has been running for 5 minutes, open the dryer door and feel for heat. If you feel heat, cancel cycle and close door. If you do not feel heat, turn off the dryer and check to see that the gas supply line shutoff valve is open.

If the gas supply line shutoff valve is closed, open it, then repeat the 5-minute test as outlined above.

If the gas supply line shutoff valve is open, contact a qualified technician.

14

Image 14
Contents Gas Dryer Table of Contents Kenmore Appliance and Optional Pedestal WarrantyPedestal Product Record Dryer SafetyModel number Safety Instructions Parts needed PedestalParts supplied Stack KitInstallation clearances Custom undercounter installation Dryer onlyMobile home installations require Minimum installation spacing for cabinet installationMobile home additional installation requirements Grounding iNSTRUCTiONSOption 1 Recommended method Gas supply connection requirementsGas supply line Option 2 Alternate methodBurner input requirements Clamp Optional exhaust installationsGoodBetter Louvered hood style Box hood styleVent system chart Alternate installations for close clearancesSpecial provisions for mobile home installations Determine vent pathFor mobile home use Flared male fitting Non-flared male fittingRemove the door assembly Reverse hingePlug into a grounded 3 prong outlet If the dryer will not start, check the followingDryness Dryer USETo use an Auto Cycle To pause/stop the dryer at any time To end/cancel your dryer at any timeTo use a Timed Cycle Loading suggestionsCycle tips Dry most loads using the preset cycle settings Auto Cycles Preset Settings Wrin KLE Guard Dryer Care From the Exhaust Vent To clean dryer drumFrom Inside the Dryer Cabinet Moving careUnusual sounds TroubleshootingNo heat Dryer displaying code messageLint on load Is the lint screen clogged? Sears Installation ServiceExplosion Hazard Master Protection AgreementsCuidado SeguridadUSO DE LA Secadora SolucionRegistro DEL Producto Garantia Limitada DE UN AiioExclusion DE Garantias Implcitas Limitacion DE Recursos Registro DE Producto DEL PedestalSeguridad DE LA Secadora Su seguridad y la seguridad de los demas es muy importanteADVERTENClA Patas niveladoras PedestalPiezas suministradas Piezas para adquirirInstalacibn en el cl6set S61o secadora Dimensiones de la secadoraEspacios para la Instalacibn Espacio minimo para la instalacibn en un armario Las instalaciones en casas rodantes necesitanTipo de gas Gas natural Peligro de Choque ElctricoPeligro de E×plosi6n La conversi6n debera Ilevarla a cabo un tcnico calificadoOpcibn 2 Mtodo alternativo Requisitos para la conexibn del suministro de gasOpcibn 1 Mtodo recomendado Elevaciones encima de los 10.000 pies 3.048 metrosIlamar al 1-800-4-MY-HOME Si este es un nuevo sistema de ventilacibnMaterial de ventilacibn Ducto de escape de metal flexiblePeligro de Incendio Pieza nQmero26-49901 Desacoplo de menos de 5 12,7 cmInstalaciones opcionales de escape Instalaciones alternas para espacios limitadosMetal Cuadro del sistema de ventilaci6nNo. de Tipo de Capotas de Metal RigidoPara su uso en casas rodantes Accesorios macho abocinados Accesorios macho no abocinadosC6mo quitar el ensamblaje de la puerta Invierta la bisagraVuelva a instalar la puerta Si la secadora no funciona, revise Io siguienteUsa DE LA Secadora Para usar un ciclo de secado automticoPara usar un ciclo programado £ t ¢i,*SDryness Level De capacidad Superior Ropa de trabajo pesadaOcos s£om4t£cos Ajustes prefijados de ciclos programados Ropa delicada DelicateAjustes prefijados de ciclos automaticos TouchSerial de ciclo Cuando use s61o aireProtector antiarrugas Wrin KLE Guard e Cambio de ciclos despus de presionar puesta en marcha@OJ£Ie ImportanteIXOYt,, I?q1,f@,,,/ii,¢ Solucion DE ProblemasCuidado para las vacaciones Sin calorEsta el filtro de pelusa obstruido con pelusa? La secadora muestra mensajes codificadosEl tiempo del ciclo es demasiado corto Esta la secadora ubicada en un armario?Contratos Maestros de Proteccibn ProteccionPelusa en la ropa Esta obstruido el filtro de pelusa? Revisibn Anual de Mantenimiento Preventivo a solicitudSea rs