D. FRESH AIR SUPPLY

The EURO-24 air supply (makeup air) must be given careful consideration to assure proper performance of each dryer. An unrestricted source of air is necessary for each dryer. As a general rule, an unrestricted air entrance from the outdoors (atmosphere) of a minimum of 1-1/2 square feet (0.14 square meters) is required for each dryer. If registers or louvers are installed over the openings, then the area must be increased. It is not necessary to have a separate make-up air openings for each dryer. Common make-up air openings are acceptable. However, they must be set up in such a manner that the make-up air is distributed equally to the dryers.

EXAMPLE: For a bank of eight (8) dryers, two (2) unrestricted openings measuring 2 feet (0.61 meters) by 3 feet (0.91 meters) (6 square feet or 0.56 square meters) is acceptable.

IMPORTANT: Makeup air openings should not be located in an area directly near where exhaust vents exit the building.

Allowances must be made for remote or constricting passageways or where dryers are located at excessive altitudes or predominantly low pressure areas.

IMPORTANT: Makeup air must be provided from a source free of dry cleaning solvent fumes. Makeup air that is contaminated by dry cleaning solvent fumes will result in irreparable damage to motors and other dryer components.

NOTE: Component failure due to dry cleaning solvent fumes will VOID THE WARRANTY.

11

Image 15
Contents EURO-24 Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Routine Maintenance Important Information SectionPersonal Injury or Fire could Result Safety PrecautionsStandards Specifications SpecificationsSpecifications UNPACKING/SETTING UP Installation ProceduresLocation Requirements Dryer Enclosure Requirements Fresh AIR Supply Exhaust Requirements Single Dryer Venting Illus. B Multiple Dryer Common Venting ILLUS. D Important Venting Reminders Electrical Information Must be Provided Black White Green Neutral Important a Circuit Serving Each Dryer Must be Provided Important a Circuit Serving Each Dryer Must be Provided EURO-24 GAS EURO-24 Steam Electrical Service Specifications PER DryerInjury and Improper Operation of the Dryer GAS Information14.92 29.9 mb 26.1 mbPage Page 862 KPa Steam InformationPage Compressed AIR Supply AIR Pressure Page Steam Damper Air Piston Flow Control Operation Adjustment Preparation for OPERATION/START-UP GAS Models only Preoperational TestsBasket Coating Preoperational InstructionsPage OPL Models Shut Down Instructions SERVICE/PARTS Information ServiceParts Returning Warranty Parts Warranty InformationReturning Warranty Cards WarrantyPage Cleaning Routine MaintenanceLubrication AdjustmentsLint Drawer Removal Troubleshooting No L.E.D. light emitting diode displayDrive motor not operating does not start Blower motor not operating does not start Microprocessor controller computer display reads door Microprocessor computer display reads dSFLPage Failed oven contactor/relay Failed heat selector switch Condensation on main door glass Dryer operates but is taking too long to dryExcessive noise and/or vibration Scraping noise from basket tumbler areaHeating unit not operating ALL temperature selections Drive motor only not operatingBlower motor only not operating Dryer operates but is taking too long to dry load Heat unit not operating for only one 1 temperature selectionSail switch is fluttering for GAS and Electric Models only Data Label Technical InformationData Label Timing Legend Reversing Timer SPIN/DWELL AdjustmentsProcedure for Functional Check Replacement Components Page ADC 08/03/99-25 01/18/00-25 07/14/00-20