American Dryer Corp EURO-24 manual Shut Down Instructions

Page 42

1)Display will read "READY" (meaning no cycle in progress).

2)Press the letter on the keyboard (touch pad) corresponding to the cycle desired (i.e., Key "E"). Dryer will start to rotate.

3)L.E.D. display will now toggle "Drying" "manual" "Cycle" "30 Min" "Remain" meaning the dryer is in the drying cycle and count down in minutes.

NOTE: Pressing touch pad key "A", "B", "C", "D", and "F" will also start the dryer. The six (6) preprogrammed drying cycles ("A" - "F") have been stored in the microprocessor (computer's) memory. Refer to the Computer Programming Manual supplied with dryer for more specific operating information.

NOTE: The dryer can be stopped at any time by opening main door or by pressing the "STOP" key. The restart the dryer, press the "START" key or preprogrammed cycle key (i.e., "E").

NOTE: Selection (setting) changes can be made at any time during the drying cycle by pressing the "CLEAR/STOP" key twice. The L.E.D. display will return to "READY" at which time a new cycle selection can be made.

b.Dual Timer Dryers

1)Turn drying timer knob for a time of 20 minutes.

2)Select "High Temp."

3)Push "Push To Start" switch.

4)To stop dryer, open the main door.

L.SHUT DOWN INSTRUCTIONS

If the dryer is to be shut down (taken out of service) for a period of time, the following MUST BE performed;

1.Discontinue power to the dryer either at the external disconnect switch or the circuit breaker.

2.Discontinue the heat supply:

a. GAS MODELS ... discontinue the gas supply.

1)SHUT OFF external gas supply shut-off valve.

2)SHUT OFF internal gas supply shut-off valve located in the gas valve burner area.

a.STEAM MODELS ... discontinue the steam supply.

1)SHUT OFF external (location furnished) shut-off valve.

2)SHUT OFF internal steam valves in the supply lines and the return lines.

38

Image 42
Contents EURO-24 Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Routine Maintenance Section Important InformationSafety Precautions Personal Injury or Fire could ResultStandards Specifications SpecificationsSpecifications Installation Procedures UNPACKING/SETTING UPLocation Requirements Dryer Enclosure Requirements Fresh AIR Supply Exhaust Requirements Single Dryer Venting Illus. B Multiple Dryer Common Venting ILLUS. D Important Venting Reminders Electrical Information Must be Provided Black White Green Neutral Important a Circuit Serving Each Dryer Must be Provided Important a Circuit Serving Each Dryer Must be Provided Electrical Service Specifications PER Dryer EURO-24 GAS EURO-24 SteamGAS Information Injury and Improper Operation of the Dryer26.1 mb 14.92 29.9 mbPage Page Steam Information 862 KPaPage Compressed AIR Supply AIR Pressure Page Steam Damper Air Piston Flow Control Operation Adjustment Preparation for OPERATION/START-UP Preoperational Tests GAS Models only Preoperational Instructions Basket CoatingPage OPL Models Shut Down Instructions SERVICE/PARTS Information ServiceParts Warranty Warranty InformationReturning Warranty Cards Returning Warranty PartsPage Routine Maintenance CleaningAdjustments LubricationLint Drawer Removal Troubleshooting No L.E.D. light emitting diode displayDrive motor not operating does not start Blower motor not operating does not start Microprocessor computer display reads dSFL Microprocessor controller computer display reads doorPage Failed oven contactor/relay Failed heat selector switch Dryer operates but is taking too long to dry Condensation on main door glassScraping noise from basket tumbler area Excessive noise and/or vibrationHeating unit not operating ALL temperature selections Drive motor only not operatingBlower motor only not operating Heat unit not operating for only one 1 temperature selection Dryer operates but is taking too long to dry loadSail switch is fluttering for GAS and Electric Models only Technical Information Data LabelData Label Reversing Timer SPIN/DWELL Adjustments Timing LegendProcedure for Functional Check Replacement Components Page ADC 08/03/99-25 01/18/00-25 07/14/00-20