American Dryer Corp EURO-24 manual Reversing Timer SPIN/DWELL Adjustments, Timing Legend

Page 61

SECTION IX

REVERSING TIMER SPIN/DWELL

ADJUSTMENTS

Dual timer models with "reversing option" have an electric reversing timer in the electric service box which is located in the upper rear area of the dryer.

Both the dwell (stop) time and basket (tumbler) spin time are adjustable by mode selection switches located on the electronic timer (as noted in the illustration below).

TIMING LEGEND

SPIN TIME

Switch Position Number

1

2

3

4

5

 

 

 

 

 

 

Time in Seconds*

30

60

90

120

150

 

 

 

 

 

 

 

 

 

 

 

 

DWELL (STOP) TIME

1

2

3

4

5

 

 

 

 

 

 

Switch Position Number

5

6

8

10

12

 

 

 

 

 

 

* Values shown are +/- 1 second.

57

Image 61
Contents EURO-24 Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Routine Maintenance Important Information SectionPersonal Injury or Fire could Result Safety PrecautionsStandards Specifications SpecificationsSpecifications UNPACKING/SETTING UP Installation ProceduresLocation Requirements Dryer Enclosure Requirements Fresh AIR Supply Exhaust Requirements Single Dryer Venting Illus. B Multiple Dryer Common Venting ILLUS. D Important Venting Reminders Electrical Information Must be Provided Black White Green Neutral Important a Circuit Serving Each Dryer Must be Provided Important a Circuit Serving Each Dryer Must be Provided EURO-24 GAS EURO-24 Steam Electrical Service Specifications PER DryerInjury and Improper Operation of the Dryer GAS Information14.92 29.9 mb 26.1 mbPage Page 862 KPa Steam InformationPage Compressed AIR Supply AIR Pressure Page Steam Damper Air Piston Flow Control Operation Adjustment Preparation for OPERATION/START-UP GAS Models only Preoperational TestsBasket Coating Preoperational InstructionsPage OPL Models Shut Down Instructions Service SERVICE/PARTS InformationParts Returning Warranty Cards Warranty InformationWarranty Returning Warranty PartsPage Cleaning Routine MaintenanceLubrication AdjustmentsLint Drawer Removal No L.E.D. light emitting diode display TroubleshootingDrive motor not operating does not start Blower motor not operating does not start Microprocessor controller computer display reads door Microprocessor computer display reads dSFLPage Failed oven contactor/relay Failed heat selector switch Condensation on main door glass Dryer operates but is taking too long to dryExcessive noise and/or vibration Scraping noise from basket tumbler areaDrive motor only not operating Heating unit not operating ALL temperature selectionsBlower motor only not operating Dryer operates but is taking too long to dry load Heat unit not operating for only one 1 temperature selection Sail switch is fluttering for GAS and Electric Models only Data Label Technical InformationData Label Timing Legend Reversing Timer SPIN/DWELL AdjustmentsProcedure for Functional Check Replacement Components Page ADC 08/03/99-25 01/18/00-25 07/14/00-20