American Dryer Corp EURO-24 manual Steam Damper Air Piston Flow Control Operation Adjustment

Page 36

a.Steam Damper Air Piston (Flow Control) Operation Adjustment

Damper operation was tested and adjusted prior to shipping at 80 psi (552 KPa). If damper air adjustment is necessary, locate the flow control valve and make the necessary adjustments as noted below.

32

Image 36
Contents EURO-24 Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Routine Maintenance Section Important InformationSafety Precautions Personal Injury or Fire could ResultStandards Specifications SpecificationsSpecifications Installation Procedures UNPACKING/SETTING UPLocation Requirements Dryer Enclosure Requirements Fresh AIR Supply Exhaust Requirements Single Dryer Venting Illus. B Multiple Dryer Common Venting ILLUS. D Important Venting Reminders Electrical Information Must be Provided Black White Green Neutral Important a Circuit Serving Each Dryer Must be Provided Important a Circuit Serving Each Dryer Must be Provided Electrical Service Specifications PER Dryer EURO-24 GAS EURO-24 SteamGAS Information Injury and Improper Operation of the Dryer26.1 mb 14.92 29.9 mbPage Page Steam Information 862 KPaPage Compressed AIR Supply AIR Pressure Page Steam Damper Air Piston Flow Control Operation Adjustment Preparation for OPERATION/START-UP Preoperational Tests GAS Models onlyPreoperational Instructions Basket CoatingPage OPL Models Shut Down Instructions SERVICE/PARTS Information ServiceParts Warranty Information Returning Warranty CardsWarranty Returning Warranty PartsPage Routine Maintenance CleaningAdjustments LubricationLint Drawer Removal Troubleshooting No L.E.D. light emitting diode displayDrive motor not operating does not start Blower motor not operating does not start Microprocessor computer display reads dSFL Microprocessor controller computer display reads doorPage Failed oven contactor/relay Failed heat selector switch Dryer operates but is taking too long to dry Condensation on main door glassScraping noise from basket tumbler area Excessive noise and/or vibrationHeating unit not operating ALL temperature selections Drive motor only not operatingBlower motor only not operating Heat unit not operating for only one 1 temperature selection Dryer operates but is taking too long to dry loadSail switch is fluttering for GAS and Electric Models only Technical Information Data LabelData Label Reversing Timer SPIN/DWELL Adjustments Timing LegendProcedure for Functional Check Replacement Components Page ADC 08/03/99-25 01/18/00-25 07/14/00-20