K.Microprocessor controller (computer) will not accept any keyboard entries, i.e., L.E.D. (light emitting diode) display reads "FILL" and when keyboard entries are selected, the L.E.D. display continues to read "FILL"...

1.Failed keyboard label (touchpad) assembly.

2.Failed microprocessor controller (computer).

L.Microprocessor controller will only accept certain keyboard entries...

1.Failed keyboard label (touchpad) assembly.

2.Failed microprocessor controller (computer).

M.Microprocessor controller (computer) locks up and L.E.D. (light emitting diode) display reads erroneous message(s) or only partial segments...

1.Transient power voltage (spikes)...disconnect power to dryer, wait one (1) minute, and reestablish power to dryer. If problem is still evident ...

a.Failed microprocessor controller (computer).

b.Failed keyboard label (touchpad) assembly.

N.Dryer stops during a cycle and L.E.D. (light emitting diode) display returns to "FILL"...

1.Fault in microprocessor heat sensor circuit ...

a.Loose connection in wires between temperature sensor and microprocessor controller (computer).

2.Loose connection somewhere in main power circuit to microprocessor controller (computer).

O.No heat (for GAS MODELS ONLY)...ignitor glows, burner goes on and off right away...

1.Flame Probe out of adjustment...reposition closer to the flame area.

2.Sail switch is fluttering ...

a.Lint drawer/screen dirty.

b.Restriction in exhaust duct work.

3.Insufficient make-up air.

4.Failed flame probe.

5.Failed Hot Suface Ignition (HSI) module.

6.Failed gas valve.

48

Image 52
Contents EURO-24 Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Routine Maintenance Section Important InformationSafety Precautions Personal Injury or Fire could ResultStandards Specifications SpecificationsSpecifications Installation Procedures UNPACKING/SETTING UPLocation Requirements Dryer Enclosure Requirements Fresh AIR Supply Exhaust Requirements Single Dryer Venting Illus. B Multiple Dryer Common Venting ILLUS. D Important Venting Reminders Electrical Information Must be Provided Black White Green Neutral Important a Circuit Serving Each Dryer Must be Provided Important a Circuit Serving Each Dryer Must be Provided Electrical Service Specifications PER Dryer EURO-24 GAS EURO-24 SteamGAS Information Injury and Improper Operation of the Dryer26.1 mb 14.92 29.9 mbPage Page Steam Information 862 KPaPage Compressed AIR Supply AIR Pressure Page Steam Damper Air Piston Flow Control Operation Adjustment Preparation for OPERATION/START-UP Preoperational Tests GAS Models onlyPreoperational Instructions Basket CoatingPage OPL Models Shut Down Instructions Service SERVICE/PARTS InformationParts Warranty Information Returning Warranty CardsWarranty Returning Warranty PartsPage Routine Maintenance CleaningAdjustments LubricationLint Drawer Removal No L.E.D. light emitting diode display TroubleshootingDrive motor not operating does not start Blower motor not operating does not start Microprocessor computer display reads dSFL Microprocessor controller computer display reads doorPage Failed oven contactor/relay Failed heat selector switch Dryer operates but is taking too long to dry Condensation on main door glassScraping noise from basket tumbler area Excessive noise and/or vibrationDrive motor only not operating Heating unit not operating ALL temperature selectionsBlower motor only not operating Heat unit not operating for only one 1 temperature selection Dryer operates but is taking too long to dry loadSail switch is fluttering for GAS and Electric Models only Technical Information Data LabelData Label Reversing Timer SPIN/DWELL Adjustments Timing LegendProcedure for Functional Check Replacement Components Page ADC 08/03/99-25 01/18/00-25 07/14/00-20