J. PREOPERATIONAL TESTS

ALL dryers are thoroughly tested and inspected before leaving the factory. However, a preoperational test should be performed before the dryer is publicly used. It is possible that adjustments have changed in transit or due to marginal location (installation) conditions.

1.Turn on electric power to the dryer.

2.Refer to the Operating Instructions for starting your particular model dryer.

3.GAS MODELS ONLY

a.When a gas dryer is first started (during initial start-up), it has a tendency not to ignite on the first ignition attempt. This is because the gas supply piping is filled with air, so it may take a few minutes for the air to be purged from the lines.

NOTE: During the purging period, check to be sure that ALL gas shut-off valves are open.

NOTE: Gas model dryers are equipped with a Hot Surface Ignition (HSI) system which has internal diagnostics. If ignition is not established after one (1) time, the heat circuit in the HSI module will attempt two more ignitions (total of three ignition attempts). If there is no flame after the third ignition attempt the HSI module will lock out until it is manually reset. To reset the HSI (Hot Surface Ignition) system, open and close the main door and restart the dryer.

b.A gas pressure test should be taken at the gas valve pressure tap of each dryer to assure that the water column (W.C.) pressure is correct and consistent.

NOTE: Water column (W.C.) pressure requirements (measured at the pressure tap of the gas valve body):

Natural Gas -----------------

3.5 Inches Water Column (8.7 mbar)

Liquid Propane (L.P.) Gas ---

10.5 Inches Water Column (26.2 mbar)

IMPORTANT: There is no regulator provided in an L.P. dryer. The water column pressure must be regulated at the source (L.P. tank), or an external regulator must be added to each dryer.

4.Make a complete operational check of ALL safety related circuits:

a.Door Switch(es)

b.Hi-Limit thermostats

c.Cycling thermostat

d.GAS and ELECTRIC MODELS ONLY - Sail Switch

NOTE: The sail switch can be checked for proper operation by opening the lint drawer. While Pushing the lint drawer switch in, start a drying cycle. The heating unit should not activate (wait 30 sec.) If heat does activate, make necessary adjustments to the sail switch.

34

Image 38
Contents EURO-24 Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Routine Maintenance Section Important InformationSafety Precautions Personal Injury or Fire could ResultStandards Specifications SpecificationsSpecifications Installation Procedures UNPACKING/SETTING UPLocation Requirements Dryer Enclosure Requirements Fresh AIR Supply Exhaust Requirements Single Dryer Venting Illus. B Multiple Dryer Common Venting ILLUS. D Important Venting Reminders Electrical Information Must be Provided Black White Green Neutral Important a Circuit Serving Each Dryer Must be Provided Important a Circuit Serving Each Dryer Must be Provided Electrical Service Specifications PER Dryer EURO-24 GAS EURO-24 SteamGAS Information Injury and Improper Operation of the Dryer26.1 mb 14.92 29.9 mbPage Page Steam Information 862 KPaPage Compressed AIR Supply AIR Pressure Page Steam Damper Air Piston Flow Control Operation Adjustment Preparation for OPERATION/START-UP Preoperational Tests GAS Models onlyPreoperational Instructions Basket CoatingPage OPL Models Shut Down Instructions Parts SERVICE/PARTS InformationService Warranty Warranty InformationReturning Warranty Cards Returning Warranty PartsPage Routine Maintenance CleaningAdjustments LubricationLint Drawer Removal Drive motor not operating does not start TroubleshootingNo L.E.D. light emitting diode display Blower motor not operating does not start Microprocessor computer display reads dSFL Microprocessor controller computer display reads doorPage Failed oven contactor/relay Failed heat selector switch Dryer operates but is taking too long to dry Condensation on main door glassScraping noise from basket tumbler area Excessive noise and/or vibrationBlower motor only not operating Heating unit not operating ALL temperature selectionsDrive motor only not operating Heat unit not operating for only one 1 temperature selection Dryer operates but is taking too long to dry loadSail switch is fluttering for GAS and Electric Models only Technical Information Data LabelData Label Reversing Timer SPIN/DWELL Adjustments Timing LegendProcedure for Functional Check Replacement Components Page ADC 08/03/99-25 01/18/00-25 07/14/00-20