American Dryer Corp None Selecting DRY Mode, Free DRY Mode, Select Pause Time 0 to, Minutes

Page 33

SELECTING DRY MODE

READY, INSERT

0.25¢ TO START

PROGRAM MODE

PL #01

CONTROL

SETTINGS

SELECT

LANGUAGE

SELECT DRY

MODE

COIN DRY MODE

FROM READY MODE TOGGLE PROGRAM SWITCH TO UP POSITION.

PRESS "MED" TO

ENTER PROGRAM

MENU.

PRESS "MED" TO ENTER PL #01

CONTROL SETTINGS.

PRESS "HI" FOUR (4) TIMES TO SCAN UP TO SELECT DRY MODE PARAMETER.

PRESS "MED" TO

ENTER DRY MODE

PARAMETER.

PRESS "HI" OR "LO" TO TOGGLE BETWEEN COIN AND FREE DRY MODE.

FREE DRY MODE

 

PRESS "MED" TO

 

SELECT DRY MODE,

 

AND ADVANCE TO

 

NEXT PARAMETER.

SELECT PAUSE

NOTE: PRESS "PAUSE" TO

TIME 0 TO 3

EXIT PL #01 CONTROL

SETTINGS MEMORY

MINUTES

LOCATION

31

Image 33
Contents DMC Important Note to Purchaser Retain This Manual In a Safe Place For Future ReferenceTable of Contents Section Phase 7 Dual Microprocessor Controller DMC Computer Section Features Keyboard Touch Pad Symbols = PAUSE/CLEAR key Free Mode Coin ModeHOT Keys Pause Mode Scrolling RateRPM Clearing Fault Records and Credit Accessing Coin VaultClearing CREDIT/CLEARING Cycle Wrinkle GuardA.F.E. System D. Operating Messages Select Temp to Start Messages Common to Coin and Free ModesClose Lint Access Select DRY Mode Select Buzzer ModeSelect Language Select Temp ScaleEnter Lint Cleaning Frequency 0 to 10 Hours Select Rotation Sensor ModePause Time 0 to 3 Minutes Ready PromptFree Mode Coin ModeAxial Thermistor Input Thermistor Temp SET Point 100 to 400FTime for TOP OFF 1 to 99 Minutes Currency SymbolEnter High DRY Temp 100 to 190F Cool Time 0 to 9 MinutesAccumulative Time Select Vending ModeDual CoinAcceptor Accumulative Coin Dual CoinAcceptor No Faults Select Vending SafeguardFaults Enter LEFT/RIGHT Coin Denomination 0.05 toIntroduction to Programming Programming InstructionsProgram Location Summary MED Programming FlowchartsFlowchart Table of Contents Control Settings Select Language English Spanish Temp Scale Program ModeSelecting Display Language READY, InsertControl Settings Select Language Select Temp Scale Select Buzzer ModeSelecting Temp Scale Control Settings Select Language Buzzer Mode Selecting Buzzer ModeOFF CountControl Settings Select Language Beep Count 1 to 9 Beeps Select DRY ModeSelecting Beep Count Free DRY Mode Selecting DRY ModeSelect Pause Time 0 to MinutesSelect Language Pause Time 0 to Minutes Select Ready Prompt Selecting Pause TimeSelecting Ready Prompt ReadyMachine Selecting Model Type Machine Settings Select Model Type GAS Single MotorElectric Single Motor RotationSetting Rotation Sensor Settings Axial Setting Lint Cleaning FrequencyLint Cleaning Frequency 0 to Hours MachineOFF Setting Axial Thermistor InputTemp Setpoint Axial Thermistor InputThermistor Temp Setting Thermistor Temp SET PointHI KEY- Setting Time for Amount to Start HI KEY- Setting Time for TOP OFF Time for TOPTime for TOP OFF To 99 Minutes PL #03 HI KEY Settings HI KEY- Setting DRY Temp 100 to 190 FTime for Amount to Start 1 to Minutes Cool Time 0 to MinutesPL#04 MED KEY Settings HI KEY- Setting Cool Time 0 to 9 MinutesPL #01 Control Settings MED KEY- Setting Time for Amount to StartPL #04 MED KEY Settings Time for Amount to Start 1 to MinutesMED KEY- Setting Time for TOP OFF Cool Time 0 to Minutes MED KEY- Setting DRY Temp 100 to 190 FPL #05 LO KEY Settings MED KEY- Setting Cool Time 0 to 9 MinutesLO KEY- Setting Time for Amount to Start Time for TOP OFF To 99 Minutes LO KEY- Setting Time for TOP OFFLO KEY- Setting DRY Temp 100 to 190 F PL #06 Vending Parameters LO KEY- Setting Cool Time 0 to 9 MinutesVending Mode Selecting Currency SymbolSelecting Vending Mode Selecting Vending Safeguard Control Settings PL #06 Vending Setting Left Coin DenominationAmount to Start 0.05 to Setting Right Coin DenominationSetting Amount to Start Amount forTOP OFF 0.05 to Setting Amount for TOP OFF 0.05 to PL#07 Fault RecordingAmount for TOP OFF PL #01 Control Settings Accessing Upper Dryer Fault RecordsPL #07 Fault Recording Upper Dryer FaultsAccessing Lower Dryer Fault Records PL #01 Control Settings PL #07 Fault RecordingLower Dryer Faults Flowchart for Clearing Credit YES Accessing and Clearing Coin Vault TotalHI KEY Settings Factory DefaultsMED KEY Settings LO KEY SettingsControl Settings Language Fault Recording READY-INSERT Amount to StartUSD Diagnostic L.C.D. Fault Messages Error MessagesStandards Page Page Page A.F.E. System Diagnostic Conditions Drive Green L.E.D FAN Green L.E.D FSS Green L.E.D INPUT/OUTPUT I/O Board L.E.D. IndicatorsLint RED L.E.D Keyboard Touch PAD Layout Page ADC Part No 10/01/08