SAIL SWITCH CLOSED FAULT – This routine prevents the startup of the dryer unless the sail switch is in the open position. If the sail switch is in the closed position prior to starting, the Phase 7 dual microprocessor controller (DMC) computer will display “PLEASE WAIT START UP IN PROCESS” and will allow the Phase 7 DMC (computer) 10-seconds for the sail switch to open before faulting out on a “SAIL SWITCH CLOSED FAULT –SELECT TEMPERATURE TO RESTART”. This routine is also monitored at every startup, including a startup after being in Pause Mode. If the sail switch is in the closed position prior to starting from a Pause Mode, the Phase 7 DMC (computer) will display “PLEASE WAIT RESTART IN PROCESS” and will allow the Phase 7 DMC (computer) 10-seconds for the sail switch to open before faulting out on a “SAIL SWITCH CLOSED FAULT –SELECT TEMPERATURE TO RESTART”. Again, once the dryer faults out on the “SAIL SWITCH CLOSED FAULT –SELECT TEMPERATURE TO RESTART”, the dryer will not be allowed to start. Anytime the fault occurs, there will be an audio indication and start/restart will be prevented until a temperature cycle has been selected again.

SAIL SWITCH OPEN FAULT – If the sail switch does not close within 8-seconds of starting or restarting a cycle, the Phase 7 DMC (computer) will display “SAIL SWITCH OPEN FAULT – CHECK LINT AND MAIN DOOR THEN SELECT TEMPERATURE TO RESTART” condition. If the sail switch opens during a cycle, the Phase 7 DMC (computer) will immediately shut off the heat output and will monitor how long the sail switch is open. If the sail switch is open for more than 30-seconds, the Phase 7 DMC (computer) will display

“SAIL SWITCH OPEN FAULT – CHECK LINT AND MAIN DOOR THEN SELECT TEMPERATURE TO RESTART” condition and with a brief audio indication. Once this condition occurs the Phase 7 DMC (computer) will shut off ALL outputs and will remain in this mode until the dryer is addressed and a new temperature cycle has been selected.

BURNER HIGH-LIMIT FAULT – This routine monitors the burner high-limit switch. If the Phase 7 DMC (computer) senses the switch open for more than 3-seconds, it will consider this an error and will proceed accordingly. If the switch opens during the cycle, while the heat is on and stays open for more than 15 minutes, the dryer will display “BURNER HIGH-LIMIT FAULT” and will go into a Fault Mode with a brief audio indication. Also, if the switch opens three (3) times within 1 hour of drying time, the dryer will display “BURNER HIGH-LIMIT FAULT” and will go into a Fault Mode with a brief audio indication. Once a fault is detected, the Phase 7 DMC (computer) will check the basket (tumbler) temperature. If the exhaust probe temperature is above 100°F (38°C), the dryer will continue to display “BURNER HIGH-LIMIT FAULT” while the dryer cools by running with no heat for 3 minutes or until the temperature drops below 100°F (38°C). Once the exhaust probe temperature is below 100°F (38°C), or the 3 minutes expire, the Phase 7 DMC (computer) will shut off ALL outputs and will remain in Fault Mode.

EXHAUST HIGH-LIMIT FAULT – This routine monitors the exhaust high-limit switch. If the Phase 7 DMC (computer) senses the switch open for more than 3-seconds it will consider this an error and will proceed accordingly. If the switch opens and stays open for more than 15 minutes, the dryer will display “EXHAUST HIGH-LIMIT FAULT” and will go into a Fault Mode with a brief audio indication. Also, if the switch opens three

(3)times within 1 hour of drying time, the dryer will display “EXHAUST HIGH-LIMIT FAULT” and will go into a Fault Mode with a brief audio indication. Once a fault is detected, the Phase 7 DMC (computer) will check the basket (tumbler) temperature. If the exhaust probe temperature is above 100°F (38°C), the dryer will continue to display “EXHAUST HIGH-LIMIT FAULT”, while the dryer cools by running with no heat for 3 minutes or until the temperature drops below 100°F (38°C). Once the exhaust probe temperature is below 100°F (38°C), or the 3 minutes expire, the Phase 7 DMC (computer) will shut off ALL outputs and will remain in Fault Mode.

66

Image 68
Contents DMC Retain This Manual In a Safe Place For Future Reference Important Note to PurchaserTable of Contents Section Phase 7 Dual Microprocessor Controller DMC Computer Section Features Keyboard Touch Pad Symbols = PAUSE/CLEAR key Coin Mode Free ModeHOT Keys RPM Pause ModeScrolling Rate Accessing Coin Vault Clearing Fault Records and CreditClearing CREDIT/CLEARING Cycle Wrinkle GuardA.F.E. System D. Operating Messages Messages Common to Coin and Free Modes Select Temp to StartClose Lint Access Select Buzzer Mode Select DRY ModeSelect Language Select Temp ScaleSelect Rotation Sensor Mode Enter Lint Cleaning Frequency 0 to 10 HoursPause Time 0 to 3 Minutes Ready PromptCoin Mode Free ModeAxial Thermistor Input Thermistor Temp SET Point 100 to 400FCurrency Symbol Time for TOP OFF 1 to 99 MinutesEnter High DRY Temp 100 to 190F Cool Time 0 to 9 MinutesSelect Vending Mode Accumulative TimeDual CoinAcceptor Accumulative Coin Dual CoinAcceptor Select Vending Safeguard No FaultsFaults Enter LEFT/RIGHT Coin Denomination 0.05 toProgramming Instructions Introduction to ProgrammingProgram Location Summary Programming Flowcharts MEDFlowchart Table of Contents Program Mode Control Settings Select Language English Spanish Temp ScaleSelecting Display Language READY, InsertSelecting Temp Scale Control SettingsSelect Language Select Temp Scale Select Buzzer Mode Selecting Buzzer Mode Control Settings Select Language Buzzer ModeOFF CountSelecting Beep Count Control Settings Select Language Beep Count 1 to 9 BeepsSelect DRY Mode Selecting DRY Mode Free DRY ModeSelect Pause Time 0 to MinutesSelecting Pause Time Select Language Pause Time 0 to Minutes Select Ready PromptMachine Selecting Ready PromptReady Machine Settings Select Model Type GAS Single Motor Selecting Model TypeElectric Single Motor RotationSetting Rotation Sensor Setting Lint Cleaning Frequency Settings AxialLint Cleaning Frequency 0 to Hours MachineSetting Axial Thermistor Input OFFTemp Setpoint Axial Thermistor InputSetting Thermistor Temp SET Point Thermistor TempHI KEY- Setting Time for Amount to Start Time for TOP OFF To 99 Minutes HI KEY- Setting Time for TOP OFFTime for TOP HI KEY- Setting DRY Temp 100 to 190 F PL #03 HI KEY SettingsTime for Amount to Start 1 to Minutes Cool Time 0 to MinutesHI KEY- Setting Cool Time 0 to 9 Minutes PL#04 MED KEY SettingsMED KEY- Setting Time for Amount to Start PL #01 Control SettingsPL #04 MED KEY Settings Time for Amount to Start 1 to MinutesMED KEY- Setting Time for TOP OFF MED KEY- Setting DRY Temp 100 to 190 F Cool Time 0 to MinutesMED KEY- Setting Cool Time 0 to 9 Minutes PL #05 LO KEY SettingsLO KEY- Setting Time for Amount to Start LO KEY- Setting Time for TOP OFF Time for TOP OFF To 99 MinutesLO KEY- Setting DRY Temp 100 to 190 F LO KEY- Setting Cool Time 0 to 9 Minutes PL #06 Vending ParametersSelecting Currency Symbol Vending ModeSelecting Vending Mode Selecting Vending Safeguard Setting Left Coin Denomination Control Settings PL #06 VendingSetting Right Coin Denomination Amount to Start 0.05 toTOP OFF 0.05 to Setting Amount to StartAmount for Amount for TOP OFF Setting Amount for TOP OFF 0.05 toPL#07 Fault Recording Accessing Upper Dryer Fault Records PL #01 Control SettingsPL #07 Fault Recording Upper Dryer FaultsLower Dryer Faults Accessing Lower Dryer Fault RecordsPL #01 Control Settings PL #07 Fault Recording Flowchart for Clearing Credit Accessing and Clearing Coin Vault Total YESFactory Defaults HI KEY SettingsMED KEY Settings LO KEY SettingsControl Settings Language USD Fault RecordingREADY-INSERT Amount to Start Standards Diagnostic L.C.D. Fault MessagesError Messages Page Page Page A.F.E. System Diagnostic Conditions INPUT/OUTPUT I/O Board L.E.D. Indicators Drive Green L.E.D FAN Green L.E.D FSS Green L.E.DLint RED L.E.D Keyboard Touch PAD Layout Page ADC Part No 10/01/08