| For |
| |
|
|
| |
|
| FACTORY DEFAULTS | |
| CONTROL SETTINGS |
| |
| LANGUAGE | ENGLISH | |
| TEMP SCALE | °F | |
PL#01 | BUZZER MODE | BUZZ | |
BEEP COUNT 1 TO 9 BEEPS | 5 | ||
| DRY MODE | COIN | |
| PAUSE TIME 0 to 3 MINUTES | 1 | |
| READY PROMPT | ||
| MACHINE SETTINGS |
| |
| MODEL | reference dryer model type | |
PL#02 | ROTATION SENSOR | ON | |
LINT CLEANING FREQUENCY 0 TO 10 HOURS | 2 | ||
| AXIAL THERMISTOR INPUT | ON | |
| THERMISTOR TEMP SET POINT 100 TO 400 °F | 180 | |
| HI KEY SETTINGS |
| |
| TIME FOR AMOUNT TO START 1 TO 99 MINUTES | 10 | |
PL#03 | TIME FOR TOP OFF 1 TO 99 MINUTES | 10 | |
DRY TEMP 100 TO 190°F | 150 | ||
| |||
| COOL TIME 0 TO 9 MINUTES | 2 | |
| MED KEY SETTINGS |
| |
| TIME FOR AMOUNT TO START 1 TO 99 MINUTES | 10 | |
PL#04 | TIME FOR TOP OFF 1 TO 99 MINUTES | 10 | |
DRY TEMP 100 TO 190°F | 130 | ||
| |||
| COOL TIME 0 TO 9 MINUTES | 2 | |
| LO KEY SETTINGS |
| |
| TIME FOR AMOUNT TO START 1 TO 99 MINUTES | 10 | |
PL#05 | TIME FOR TOP OFF 1 TO 99 MINUTES | 10 | |
DRY TEMP 100 TO 190°F | 120 | ||
| |||
| COOL TIME 0 TO 9 MINUTES | 2 | |
| VENDING PARAMETERS |
| |
| CURRENCY SYMBOL | USD | |
| VENDING MODE | ACCUMULATIVE TIME | |
PL #06 | VENDING SAFEGUARD | BAD COIN RESET | |
LEFT COIN DENOMINATION 0.05 TO 25.00 * | 0.25 | ||
| RIGHT COIN DENOMINATION 0.05 TO 25.00 * | 0.10 | |
| AMOUNT TO START 0.05 TO 25.00 | 0.25 | |
| AMOUNT FOR TOP OFF 0.05 TO 25.00 | 0.25 | |
| FAULT RECORDING |
| |
PL#07 | NO UPPER DRYER FAULTS / UPPER DRYER FAULTS |
| |
NO LOWER DRYER FAULTS / LOWER DRYER FAULTS |
| ||
|
|
* Note- This setting will differ depending on the coin acceptor installed on the dryer.
63