American Dryer Corp None user manual Accessing Lower Dryer Fault Records, Lower Dryer Faults

Page 61

ACCESSING LOWER DRYER FAULT RECORDS

READY, INSERT

 

0.25 ¢ TO START

FROM READY MODE

 

 

TOGGLE PROGRAM

 

SWITCH TO UP

PROGRAM MODE

POSITION.

 

PRESS "MED" TO ENTER

 

PROGRAM MENU.

PL #01 CONTROL

SETTINGS

PL #07 FAULT RECORDING

PRESS "LO" ONE (1) TIME TO SCAN DOWN TO PL #07 FAULT RECORDING.

UPPER DRYER

FAULTS

PRESS "MED" TO ENTER PL #07 FAULT RECORDING.

PRESS "HI" TO SCAN UP TO LOWER DRYER FAULTS.

LOWER DRYER

FAULTS

1:HR=2:00 CODE= Exhaust Temp Probe Fault

2:HR=2:00 CODE= Exhaust Temp Probe Fault

Drying Temp 160°F, Cool Down Time 2 minutes, Cool

Down Temp 100°F

PRESS "MED" TO

PROCEED.

USE THE “HI” AND “LO

KEYS TO SCAN

THROUGH THE LAST 5

FAULTS THAT THE

CONTROL BOARD

DETECTED.

FOR CYCLE

INFORMATION AT THE

TIME OF THE FAULT

OCCURRENCE, PRESS

THE “MED” KEY.

Note: Press "PAUSE" To exit

PL #07 FAULT RECORDING memory location.

59

Image 61
Contents DMC Important Note to Purchaser Retain This Manual In a Safe Place For Future ReferenceTable of Contents Section Phase 7 Dual Microprocessor Controller DMC Computer Section Features Keyboard Touch Pad Symbols = PAUSE/CLEAR key Free Mode Coin ModeHOT Keys Scrolling Rate Pause ModeRPM Clearing Fault Records and Credit Accessing Coin VaultClearing CREDIT/CLEARING Cycle Wrinkle GuardA.F.E. System D. Operating Messages Select Temp to Start Messages Common to Coin and Free ModesClose Lint Access Select DRY Mode Select Buzzer ModeSelect Language Select Temp ScaleEnter Lint Cleaning Frequency 0 to 10 Hours Select Rotation Sensor ModePause Time 0 to 3 Minutes Ready PromptFree Mode Coin ModeAxial Thermistor Input Thermistor Temp SET Point 100 to 400FTime for TOP OFF 1 to 99 Minutes Currency SymbolEnter High DRY Temp 100 to 190F Cool Time 0 to 9 MinutesAccumulative Time Select Vending ModeDual CoinAcceptor Accumulative Coin Dual CoinAcceptor No Faults Select Vending SafeguardFaults Enter LEFT/RIGHT Coin Denomination 0.05 toIntroduction to Programming Programming InstructionsProgram Location Summary MED Programming FlowchartsFlowchart Table of Contents Control Settings Select Language English Spanish Temp Scale Program ModeSelecting Display Language READY, InsertSelect Language Select Temp Scale Select Buzzer Mode Control SettingsSelecting Temp Scale Control Settings Select Language Buzzer Mode Selecting Buzzer ModeOFF CountSelect DRY Mode Control Settings Select Language Beep Count 1 to 9 BeepsSelecting Beep Count Free DRY Mode Selecting DRY ModeSelect Pause Time 0 to MinutesSelect Language Pause Time 0 to Minutes Select Ready Prompt Selecting Pause TimeReady Selecting Ready PromptMachine Selecting Model Type Machine Settings Select Model Type GAS Single MotorElectric Single Motor RotationSetting Rotation Sensor Settings Axial Setting Lint Cleaning FrequencyLint Cleaning Frequency 0 to Hours MachineOFF Setting Axial Thermistor InputTemp Setpoint Axial Thermistor InputThermistor Temp Setting Thermistor Temp SET PointHI KEY- Setting Time for Amount to Start Time for TOP HI KEY- Setting Time for TOP OFFTime for TOP OFF To 99 Minutes PL #03 HI KEY Settings HI KEY- Setting DRY Temp 100 to 190 FTime for Amount to Start 1 to Minutes Cool Time 0 to MinutesPL#04 MED KEY Settings HI KEY- Setting Cool Time 0 to 9 MinutesPL #01 Control Settings MED KEY- Setting Time for Amount to StartPL #04 MED KEY Settings Time for Amount to Start 1 to MinutesMED KEY- Setting Time for TOP OFF Cool Time 0 to Minutes MED KEY- Setting DRY Temp 100 to 190 FPL #05 LO KEY Settings MED KEY- Setting Cool Time 0 to 9 MinutesLO KEY- Setting Time for Amount to Start Time for TOP OFF To 99 Minutes LO KEY- Setting Time for TOP OFFLO KEY- Setting DRY Temp 100 to 190 F PL #06 Vending Parameters LO KEY- Setting Cool Time 0 to 9 MinutesVending Mode Selecting Currency SymbolSelecting Vending Mode Selecting Vending Safeguard Control Settings PL #06 Vending Setting Left Coin DenominationAmount to Start 0.05 to Setting Right Coin DenominationAmount for Setting Amount to StartTOP OFF 0.05 to PL#07 Fault Recording Setting Amount for TOP OFF 0.05 toAmount for TOP OFF PL #01 Control Settings Accessing Upper Dryer Fault RecordsPL #07 Fault Recording Upper Dryer FaultsPL #01 Control Settings PL #07 Fault Recording Accessing Lower Dryer Fault RecordsLower Dryer Faults Flowchart for Clearing Credit YES Accessing and Clearing Coin Vault TotalHI KEY Settings Factory DefaultsMED KEY Settings LO KEY SettingsControl Settings Language READY-INSERT Amount to Start Fault RecordingUSD Error Messages Diagnostic L.C.D. Fault MessagesStandards Page Page Page A.F.E. System Diagnostic Conditions Drive Green L.E.D FAN Green L.E.D FSS Green L.E.D INPUT/OUTPUT I/O Board L.E.D. IndicatorsLint RED L.E.D Keyboard Touch PAD Layout Page ADC Part No 10/01/08