American Dryer Corp None Select Vending Safeguard, Enter LEFT/RIGHT Coin Denomination 0.05 to

Page 24

SELECT VENDING SAFEGUARD

The Phase 7 dual microprocessor controller (DMC) computer can be set to one (1) of the following safeguards:

Bad Coin Reset

When this option is selected and someone tampers with the coin acceptor or inserts a foreign object, the Phase 7 DMC (computer) will beep three (3) times and will not accept the entry. The Phase 7 DMC (computer) will automatically reset itself for the next entry.

Bad Coin Lock Out

When this option is selected and someone tampers with the coin acceptor or inserts a foreign object, the Phase 7 DMC (computer) will Lock Out and will not accept any coins for a period of 15-seconds. After 15-seconds, the Phase 7 DMC (computer) will reset itself for the next entry.

ENTER LEFT/RIGHT COIN DENOMINATION 0.05 TO 25.00

The left and right coin acceptors can be independently set to a value within the range of 0.05 to 25.00, adjustable in 0.01 increments.

AMOUNT TO START

This location determines the amount needed to start a dry cycle. The AMOUNT TO START is programmable from a minimum of 0.05 to a maximum of 25.00, adjustable in 0.01 increments.

AMOUNT FOR TOP OFF

This location determines the amount needed to add more time to a dry cycle. The amount for additional time is programmable from a minimum of 0.05 to a maximum of 25.00 minutes, adjustable in 0.01 increments.

PL #07 – FAULT RECORDING

NO FAULTS

No faults have occurred in the dryer and, therefore, no fault records have been created.

FAULTS

Whenever a fault occurs, the Phase 7 DMC (computer) will store the fault description in this location. The Phase 7 DMC (computer) will also store the hour logger time, and the temperature cycle that the pocket was in at the time of the fault. The Phase 7 DMC (computer) will store the last five (5) faults that occurred. Every time a new fault occurs, the oldest fault will be erased and the new fault will be stored.

22

Image 24
Contents DMC Retain This Manual In a Safe Place For Future Reference Important Note to PurchaserTable of Contents Section Phase 7 Dual Microprocessor Controller DMC Computer Section Features Keyboard Touch Pad Symbols = PAUSE/CLEAR key Coin Mode Free ModeHOT Keys Pause Mode Scrolling RateRPM Accessing Coin Vault Clearing Fault Records and CreditClearing CREDIT/CLEARING Cycle Wrinkle GuardA.F.E. System D. Operating Messages Messages Common to Coin and Free Modes Select Temp to StartClose Lint Access Select Buzzer Mode Select DRY ModeSelect Language Select Temp ScaleSelect Rotation Sensor Mode Enter Lint Cleaning Frequency 0 to 10 HoursPause Time 0 to 3 Minutes Ready PromptCoin Mode Free ModeAxial Thermistor Input Thermistor Temp SET Point 100 to 400FCurrency Symbol Time for TOP OFF 1 to 99 MinutesEnter High DRY Temp 100 to 190F Cool Time 0 to 9 MinutesSelect Vending Mode Accumulative TimeDual CoinAcceptor Accumulative Coin Dual CoinAcceptor Select Vending Safeguard No FaultsFaults Enter LEFT/RIGHT Coin Denomination 0.05 toProgramming Instructions Introduction to ProgrammingProgram Location Summary Programming Flowcharts MEDFlowchart Table of Contents Program Mode Control Settings Select Language English Spanish Temp ScaleSelecting Display Language READY, InsertControl Settings Select Language Select Temp Scale Select Buzzer ModeSelecting Temp Scale Selecting Buzzer Mode Control Settings Select Language Buzzer ModeOFF CountControl Settings Select Language Beep Count 1 to 9 Beeps Select DRY ModeSelecting Beep Count Selecting DRY Mode Free DRY ModeSelect Pause Time 0 to MinutesSelecting Pause Time Select Language Pause Time 0 to Minutes Select Ready PromptSelecting Ready Prompt ReadyMachine Machine Settings Select Model Type GAS Single Motor Selecting Model TypeElectric Single Motor RotationSetting Rotation Sensor Setting Lint Cleaning Frequency Settings AxialLint Cleaning Frequency 0 to Hours MachineSetting Axial Thermistor Input OFFTemp Setpoint Axial Thermistor InputSetting Thermistor Temp SET Point Thermistor TempHI KEY- Setting Time for Amount to Start HI KEY- Setting Time for TOP OFF Time for TOPTime for TOP OFF To 99 Minutes HI KEY- Setting DRY Temp 100 to 190 F PL #03 HI KEY SettingsTime for Amount to Start 1 to Minutes Cool Time 0 to MinutesHI KEY- Setting Cool Time 0 to 9 Minutes PL#04 MED KEY SettingsMED KEY- Setting Time for Amount to Start PL #01 Control SettingsPL #04 MED KEY Settings Time for Amount to Start 1 to MinutesMED KEY- Setting Time for TOP OFF MED KEY- Setting DRY Temp 100 to 190 F Cool Time 0 to MinutesMED KEY- Setting Cool Time 0 to 9 Minutes PL #05 LO KEY SettingsLO KEY- Setting Time for Amount to Start LO KEY- Setting Time for TOP OFF Time for TOP OFF To 99 MinutesLO KEY- Setting DRY Temp 100 to 190 F LO KEY- Setting Cool Time 0 to 9 Minutes PL #06 Vending ParametersSelecting Currency Symbol Vending ModeSelecting Vending Mode Selecting Vending Safeguard Setting Left Coin Denomination Control Settings PL #06 VendingSetting Right Coin Denomination Amount to Start 0.05 toSetting Amount to Start Amount forTOP OFF 0.05 to Setting Amount for TOP OFF 0.05 to PL#07 Fault RecordingAmount for TOP OFF Accessing Upper Dryer Fault Records PL #01 Control SettingsPL #07 Fault Recording Upper Dryer FaultsAccessing Lower Dryer Fault Records PL #01 Control Settings PL #07 Fault RecordingLower Dryer Faults Flowchart for Clearing Credit Accessing and Clearing Coin Vault Total YESFactory Defaults HI KEY SettingsMED KEY Settings LO KEY SettingsControl Settings Language Fault Recording READY-INSERT Amount to StartUSD Diagnostic L.C.D. Fault Messages Error MessagesStandards Page Page Page A.F.E. System Diagnostic Conditions INPUT/OUTPUT I/O Board L.E.D. Indicators Drive Green L.E.D FAN Green L.E.D FSS Green L.E.DLint RED L.E.D Keyboard Touch PAD Layout Page ADC Part No 10/01/08