American Dryer Corp Super AD-30 manual No heat for Steam Models only

Page 52

4.Failed ignitor/flame-probe assembly.

5.Failed Direct Spark Ignition (DSI) module.

6.Failed gas valve.

Q.No heat (for STEAM MODELS ONLY)...

1.Fault in lint chamber sensor bracket hi-heat (limit) protector thermostat.

2.Failed microprocessor controller (computer).

3.No (external) compressed air to steam damper (80 psi required).

4.Failed steam damper 24 VAC pneumatic solenoid switch.

5.Failed piston.

6.Steam damper stuck closed.

R.Dryer operates but is taking too long to dry ...

1.Exhaust duct work run too long or is undersized...back pressure cannot exceed .3 inches Water Column (W.C.).

2.Restriction in exhaust ...

a.Exhaust back draft damper is sticking partially closed.

b.Restriction in duct work...check duct work from dryer all the way to the outdoors.

3.Low and/or inconsistent gas pressure (for GAS MODELS ONLY).

4.Insufficient make-up air.

5.Poor air/gas mixture at burner...yellow or poor flame pattern; adjust gas burner air adjustment shutters (for GAS MODELS ONLY).

6.Lint screen not being cleaned on a regular basis or often enough.

7.Extractors (washers) not performing properly.

8.Sail switch is fluttering...restriction in exhaust (for GAS MODELS ONLY).

9.Failed microprocessor controller (computer)...temperature calibration is inaccurate.

10.Failed microprocessor temperature sensor...calibration is inaccurate.

11.Failed burner/oven hi-limit(for GAS and ELECTRIC MODELS ONLY).

12.Failed lint compartment.

13.Steam damper system not functioning properly (for STEAM MODELS ONLY) ...

48

Image 52
Contents Super AD-30 Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Troubleshooting Section Important InformationSafety Precautions What to do if YOU Smell GASPage Super AD-30 Specifications SpecificationsSpecifications Installation Procedures UNPACKING/SETTING UPLocation Requirements Section DDryer Enclosure Requirements Fresh AIR Supply Exhaust Requirements Single Dryer Venting Illus. B Multiple Dryer Common Venting ILLUS. D Important Venting Reminders Electrical Information Page Green Phase 3ø Hookup for GAS and Steam Dryers only Page Super ADG-30DS Gas Reversing Super ADS-30DS Steam Reversing GAS Information Piping/Connections Page Page Steam Information Page 70 psi Normal 80 psi90 psi Page Preparation for Operation Preoperational Tests Page Preoperational Instructions Page OPL Models Shut Down Instructions Service SERVICE/PARTS InformationParts Warranty Information Returning Warranty CardsWarranty Returning Warranty PartsPage Routine Maintenance CleaningAdjustments LubricationNo L.E.D. light emitting diode display TroubleshootingDrive motor not operating does not start Blower motor not operating does not start Microprocessor computer display reads dSFL Microprocessor controller computer display reads doorPage No heat for Steam Models only Dryer operates but is taking too long to dryDryer or scraping noise at basket tumbler area Condensation on main door glassExcessive noise and/or vibration Drive motor only not operating Blower motor only not operatingHeating unit not operating ALL temperature selections Heat unit not operating for only one 1 temperature selectionDryer operates but is taking too long to dry load Failed hi-limit thermostat for GAS and Electric Models onlyPage Reversing Timer SPIN/DWELL Adjustments Timing LegendData Label Technical InformationContact American Dryer Corporation Data Label Procedure for Functional Check Replacement Components Microprocessor computer BoardDirect Spark Ignition DSI System