American Dryer Corp Super AD-30 manual

Page 38

IMPORTANT: There is no regulator provided in an L.P. (liquid propane) dryer. The water column pressure must be regulated at the source (L.P. tank), or an external regulator must be added to each dryer.

4.Make a complete operational check of ALL safety related circuits:

a.Door Switch(es)

b.Hi-Limit thermostats

c.Cycling thermostat

d.Sail switch (for Gas Models and Electric Models Only)

NOTE: The sail switch can be checked for proper operation by opening the lint door while heating circuit (gas burner/electric oven) is active (on). The heating unit should shut off within a few seconds. If not, make necessary adjustments to sail switch.

5. Make a complete operational check of ALL operating controls.

NOTE: If computer program changes are required, refer to the computer programming section of the manual supplied with the dryer.

6.The dryer should be operated through one (1) complete cycle to assure that no further adjustments are necessary and that ALL components are functioning properly.

IMPORTANT: The dryer basket (tumbler) is treated with a protective coating. ADC suggests tumbling old clothes or material in the basket (tumbler), using a mild detergent to remove the protective coating.

7.Check the electric service phase sequence (3-phase [3ø] models only). While the dryer is operating, check to see if the blower wheel (impeller/fan) is rotating in the proper direction. Looking from the front, the blower wheel (impellor/fan) should spin in the clockwise direction. If it is, the phasing is correct. If the phasing is incorrect, reverse two (2) of the three (3) leads at connections L1, L2, L3 of the power supply to the dryer.

IMPORTANT: If the blower wheel (impellor/fan) is rotating in the wrong direction, this will not only drastically reduce drying efficiency, but it can also cause premature component failure.

34

Image 38
Contents Super AD-30 Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Troubleshooting Section Important InformationSafety Precautions What to do if YOU Smell GASPage Super AD-30 Specifications SpecificationsSpecifications Installation Procedures UNPACKING/SETTING UPLocation Requirements Section DDryer Enclosure Requirements Fresh AIR Supply Exhaust Requirements Single Dryer Venting Illus. B Multiple Dryer Common Venting ILLUS. D Important Venting Reminders Electrical Information Page Green Phase 3ø Hookup for GAS and Steam Dryers only Page Super ADG-30DS Gas Reversing Super ADS-30DS Steam Reversing GAS Information Piping/Connections Page Page Steam Information Page 90 psi Normal 80 psi70 psi Page Preparation for Operation Preoperational Tests Page Preoperational Instructions Page OPL Models Shut Down Instructions Parts SERVICE/PARTS InformationService Warranty Warranty InformationReturning Warranty Cards Returning Warranty PartsPage Routine Maintenance CleaningAdjustments LubricationDrive motor not operating does not start TroubleshootingNo L.E.D. light emitting diode display Blower motor not operating does not start Microprocessor computer display reads dSFL Microprocessor controller computer display reads doorPage No heat for Steam Models only Dryer operates but is taking too long to dryExcessive noise and/or vibration Condensation on main door glassDryer or scraping noise at basket tumbler area Drive motor only not operating Blower motor only not operatingHeating unit not operating ALL temperature selections Heat unit not operating for only one 1 temperature selectionDryer operates but is taking too long to dry load Failed hi-limit thermostat for GAS and Electric Models onlyPage Reversing Timer SPIN/DWELL Adjustments Timing LegendContact American Dryer Corporation Technical InformationData Label Data Label Procedure for Functional Check Replacement Components Microprocessor computer BoardDirect Spark Ignition DSI System