American Dryer Corp Super AD-30 manual Direct Spark Ignition DSI System

Page 62

e.Open main door. The dryer must stop and microprocessor (computer) board must go out.

ALL output indicator lights on the back side of the (Refer to illustration on previous page [page 57].)

f.Try to restart the dryer with the main door open.

g.The microprocessor (computer) board's L.E.D. display must read "DOOR."

h.Close the main door and restart the dryer.

i.Functional check of microprocessor (computer) board is complete.

2.Direct Spark Ignition (DSI) System

a.Upon completing installation of the replacement Direct Spark Ignition (DSI) module, reestablish power to the dryer.

b.Start the drying cycle.

c. The ignition (DSI) module's L.E.D. indicator will light "red" for up to approximately 1.5 seconds (pre- purge time).

d. The module's indicator light will then turn "green." The gas valve will be energized and the ignitor probe will spark for approximately 8 seconds. The burner flame should now be established.

e. With the burner flame on, remove the flame sensor wire from the FS terminal of the DSI module.

f. The burner flame must shut off and the ignition module must lock out with the DSI module's indicator light "red."

g. Stop the drying cycle, with the flame sensor wire still removed, restart the drying cycle.

h. The ignition module must proceed through the pre-purge, with the indicator light "red," the ignition trial time of approximately 8 seconds, with the indicator light "green," and then proceed to lock out with the indicator light "red".

i.Functional check of the Direct Spark Ignition (DSI) Module is complete.

1)Replace the flame sensor wire from the FS terminal to the DSI module.

58

Image 62
Contents Super AD-30 Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Troubleshooting Section Important InformationSafety Precautions What to do if YOU Smell GASPage Super AD-30 Specifications SpecificationsSpecifications Installation Procedures UNPACKING/SETTING UPLocation Requirements Section DDryer Enclosure Requirements Fresh AIR Supply Exhaust Requirements Single Dryer Venting Illus. B Multiple Dryer Common Venting ILLUS. D Important Venting Reminders Electrical Information Page Green Phase 3ø Hookup for GAS and Steam Dryers only Page Super ADG-30DS Gas Reversing Super ADS-30DS Steam Reversing GAS Information Piping/Connections Page Page Steam Information Page 90 psi Normal 80 psi70 psi Page Preparation for Operation Preoperational Tests Page Preoperational Instructions Page OPL Models Shut Down Instructions Parts SERVICE/PARTS InformationService Warranty Warranty InformationReturning Warranty Cards Returning Warranty PartsPage Routine Maintenance CleaningAdjustments LubricationDrive motor not operating does not start TroubleshootingNo L.E.D. light emitting diode display Blower motor not operating does not start Microprocessor computer display reads dSFL Microprocessor controller computer display reads doorPage No heat for Steam Models only Dryer operates but is taking too long to dryExcessive noise and/or vibration Condensation on main door glassDryer or scraping noise at basket tumbler area Drive motor only not operating Blower motor only not operatingHeating unit not operating ALL temperature selections Heat unit not operating for only one 1 temperature selectionDryer operates but is taking too long to dry load Failed hi-limit thermostat for GAS and Electric Models onlyPage Reversing Timer SPIN/DWELL Adjustments Timing LegendContact American Dryer Corporation Technical InformationData Label Data Label Procedure for Functional Check Replacement Components Microprocessor computer BoardDirect Spark Ignition DSI System