American Dryer Corp AD-15 Phase 7 Electrical Connections, KLWHRU5HG, For 110V Applications

Page 12

For added personal safety, when possible, it is suggested that a separate ground wire (no. 18 minimum) be connected from the ground connection of the dryer to a grounded cold water pipe. DO NOT ground to a gas pipe or hot water pipe. The grounded cold water pipe must have metal-to-metal connection ALL the way to the electrical ground. If there are any nonmetallic interruptions, such as, a meter, pump, plastic, rubber, or other insulating connectors, they must be jumped out with no. 4 copper wire and securely clamped to bare metal at both ends.

IMPORTANT:

!For personal safety and proper operation, the dryer must be grounded.

Provisions are made for ground connection in each dryer at the electrical service connection area.

Electrical Connections

A wiring diagram is located inside the control box for connection data.

If local codes permit, power to the dryer can be made by the use of a flexible U.L. listed power cord/pigtail (wire size must conform to rating of dryer), or the dryer can be hard wired directly to the service breaker panel. In both cases, a strain relief must be installed where the wiring enters the dryer.

Gas and Steam Models Only

IMPORTANT:

!A separate protected circuit must be provided to each dryer.

Single-Phase (1ø) Wiring Connections/Hookup

The electrical input connections on ALL single-phase (1ø) gas dryers and steam dryers are made into the rear service box located at the upper left area of the dryer.

6LQJOH￿3KDVH￿(OHFWULFDO￿/HDG￿&RQQHFWLRQV

%ODFN

:KLWH￿RU￿5HG

*UHHQ

￿

￿

￿

1HXWUDO

3RVLWLYH

*URXQG

RU￿/￿

 

 

 

 

 

For 110V Applications

10

American Dryer Corp.

113243-1

Image 12
Contents AD-15 Phase Installation Manual ADC Part NoRetain This Manual In a Safe Place For Future Reference Date of Purchase Model no RESELLER’S Name Serial NumbersTable of Contents Safety Precautions What to do if YOU Smell GASLatest Edition Specifications FIPInstallation Procedures UNPACKING/SETTING UPLocation Requirements Dryer Enclosure Requirements Fresh AIR Supply RequirementsExhaust Requirements Single Dryer Venting Horizontal VentingIllus. a Vertical Venting Illus. B Illus. CMultiple Dryer Common Venting Important Venting Reminders Electrical InformationGas and Steam Models Only GroundingElectrical Connections KLWHRU5HGFor 110V Applications For 208-230/240V Applications GAS Information Gas SupplyNever Test for Leaks with a Flame Steam InformationVoid the Warranty 1RUPDO 0LQLPXP6XSSO\0DLPXP6XSSO\ GAS and Electric Models the sail switch Preparation for OPERATION/START-UPPreoperational Tests GAS and Electric Models only Sail Switch Basket Tumbler CoatingPreoperational Instructions Reversing Timer SPIN/DWELL Adjustments MIN RemainSERVICE/PARTS Information Warranty InformationRoutine Maintenance CleaningSuggested Cleaning Schedule Data Label Information Procedure for 113243-1 Manual Reset Burner HI-LIMIT Instructions PhaseDual Timer Installation Before YOU Start Check Local Codes and PermitsOptional Manual Bypass NON-COIN CoinF.E. System Diagnostics Messages F.E. System Parts Break DownADC 113243 1 2/03/04