GAS INFORMATION
It is your responsibility to have ALL plumbing connections made by a qualified professional to ensure that the gas plumbing installation is adequate and conforms with local and state regulations or codes. In the absence of such codes, ALL plumbing connections, materials, and workmanship must conform to the applicable requirements of the National Fuel Gas Code ANSI
IMPORTANT:
!Failure to comply with codes or ordinances, and/ or requirements in this manual, can result in personal injury and improper operation of the dryer.
The dryer and its individual shutoff valves must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). The dryer must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure test of the gas supply system at test pressures equal to or less than 1/2 psig (3.5 kPa).
IMPORTANT:
!Failure to isolate or disconnect the dryer from supply as noted can cause irreparable damage to the gas valve, which will VOID THE WARRANTY.
WARNING:
FIRE OR EXPLOSION COULD RESULT due to failure of isolating or disconnecting the gas supply as noted.
Gas Supply
The gas dryer installation must meet the American National Standard...National Fuel Gas Code ANSI
NOTE:
!Undersized gas piping will result in ignition problems, slow drying, increased use of energy, and can create a safety hazard.
The dryer must be connected to the type of heat/gas indicated on the dryer data label. If this information does not agree with the type of gas available, DO NOT operate the dryer. Contact the reseller who sold the dryer or contact the ADC factory.
IMPORTANT:
!Any burner changes or conversions must be made by a qualified professional.
The input ratings shown on the dryer data label are for elevations up to 2,000 feet (609.6 meters), unless elevation requirements of over 2,000 feet (609.6 meters) were specified at the time the dryer order was placed with the factory. The adjustment or conversion of dryers in the field for elevations over 2,000 feet (609.6 meters) is made by changing each burner orifice. If this conversion is necessary, contact the reseller who sold the dryer or contact the ADC factory.
IMPORTANT:
!This gas dryer is not provided with an internal gas supply shutoff and an external gas supply shutoff must be provided.
Technical Gas Data
Gas Specifications
0DQLIROG,Q/LQH3UHVVXUH3UHVVXUHLQFKHV1$785:7<3(&$/PE2)*$/,48,'L6QFKHV:&3523PE$1(
Shaded areas are stated in metric equivalents
* Measured at outlet side of gas valve pressure tap when the gas valve is on.
Gas Connections |
|
Inlet connection | 1/2” N.P.T. |
Inlet supply size | 1/2” pipe (minimum) |
Btu/hr input 50,000 (12,600 kcal/hr)
Natural Gas
Regulation is controlled by the dryer’s gas valve’s internal regulator. Incoming supply pressure must be consistent between a minimum of 6.0 inches (14.92 mb) and a maximum of 12.0 inches (29.9 mb) water column (W.C.) pressure.
Liquid Propane (L.P.) Gas
5DWLQJ%WXKUNFDOUDWLQJKU4W\'01DWXUDO7<3(63DUW1R2)4W\/LTXLG3URSDQH*'0$663DUW1R3DUW13URSDQH/LTLGXPEHU.LW
Dryers made for use with L.P. gas have the gas valve’s internal pressure regulator blocked open so that&RQYHUVLRQthe gas pressure must be regulated upstream of the dryer. The pressure measured at each gas valve pressure tap must be a consistent 10.5 inches (26.1 mb) water column. There is no regulator or regulation provided in an P. dryer. The water column pressure must be regulated at the source (L.P. tank) or an external regulator must be added to each dryer.
Shaded area is stated in metric equivalent
* Drill Measurement Size (D.M.S.) equivalents are as follows:
Natural Gas | #41 | = | 0.0960” (2.4384 mm). |
Liquid Propane Gas | #54 | = | 0.0550” (1.397 mm). |
Piping Connections
ALL components/materials must conform to National Fuel Gas Code Specifications ANSI