American Dryer Corp AD-15 Phase 7 installation manual GAS Information, Gas Supply

Page 14

GAS INFORMATION

It is your responsibility to have ALL plumbing connections made by a qualified professional to ensure that the gas plumbing installation is adequate and conforms with local and state regulations or codes. In the absence of such codes, ALL plumbing connections, materials, and workmanship must conform to the applicable requirements of the National Fuel Gas Code ANSI Z223.1-LATEST EDITION, or in Canada, the Canadian Installation Codes CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (Liquid Propane [L.P.] Gas) or LATEST EDITION.

IMPORTANT:

!Failure to comply with codes or ordinances, and/ or requirements in this manual, can result in personal injury and improper operation of the dryer.

The dryer and its individual shutoff valves must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). The dryer must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure test of the gas supply system at test pressures equal to or less than 1/2 psig (3.5 kPa).

IMPORTANT:

!Failure to isolate or disconnect the dryer from supply as noted can cause irreparable damage to the gas valve, which will VOID THE WARRANTY.

WARNING:

FIRE OR EXPLOSION COULD RESULT due to failure of isolating or disconnecting the gas supply as noted.

Gas Supply

The gas dryer installation must meet the American National Standard...National Fuel Gas Code ANSI Z223.1-LATEST EDITION, or in Canada, the Canadian Installation Codes CAN/ CGA-B149.1 M91 (Natural Gas) or CAN/CGA-B149.2-M91 (L.P. Gas) or LATEST EDITION, as well as local codes and ordinances and must be done by a qualified professional.

NOTE:

!Undersized gas piping will result in ignition problems, slow drying, increased use of energy, and can create a safety hazard.

The dryer must be connected to the type of heat/gas indicated on the dryer data label. If this information does not agree with the type of gas available, DO NOT operate the dryer. Contact the reseller who sold the dryer or contact the ADC factory.

IMPORTANT:

!Any burner changes or conversions must be made by a qualified professional.

The input ratings shown on the dryer data label are for elevations up to 2,000 feet (609.6 meters), unless elevation requirements of over 2,000 feet (609.6 meters) were specified at the time the dryer order was placed with the factory. The adjustment or conversion of dryers in the field for elevations over 2,000 feet (609.6 meters) is made by changing each burner orifice. If this conversion is necessary, contact the reseller who sold the dryer or contact the ADC factory.

IMPORTANT:

!This gas dryer is not provided with an internal gas supply shutoff and an external gas supply shutoff must be provided.

Technical Gas Data

Gas Specifications

￿￿0DQLIROG,Q￿/LQH￿3UHVVXUH￿3UHVVXUH￿￿￿￿￿￿￿￿￿￿￿￿LQFKHV1$￿785:7<3(￿&￿$￿￿￿￿/￿￿￿￿￿￿￿￿￿PE2)￿*￿￿￿￿￿$/,48,'L6QFKHV￿:￿&￿￿3523￿￿￿￿￿PE$1(

Shaded areas are stated in metric equivalents

* Measured at outlet side of gas valve pressure tap when the gas valve is on.

Gas Connections

 

Inlet connection

1/2” N.P.T.

Inlet supply size

1/2” pipe (minimum)

Btu/hr input 50,000 (12,600 kcal/hr)

Natural Gas

Regulation is controlled by the dryer’s gas valve’s internal regulator. Incoming supply pressure must be consistent between a minimum of 6.0 inches (14.92 mb) and a maximum of 12.0 inches (29.9 mb) water column (W.C.) pressure.

Liquid Propane (L.P.) Gas

￿￿￿￿￿￿5DWLQJ%WXKUNFDO￿￿￿￿￿￿UDWLQJ￿KU4W\￿'￿￿￿￿01DWXUDO7<3(￿6￿￿3DUW￿￿￿￿￿￿￿1R2)￿4W\￿￿/LTXLG3URSDQH*'0￿￿￿$￿66￿￿3DUW1R￿￿￿￿￿￿￿3DUW13URSDQH￿￿￿￿￿￿/LTLGXPEHU.LW

Dryers made for use with L.P. gas have the gas valve’s internal pressure regulator blocked open so that&RQYHUVLRQthe gas￿ pressure must be regulated upstream of the dryer. The pressure measured at each gas valve pressure tap must be a consistent 10.5 inches (26.1 mb) water column. There is no regulator or regulation provided in an P. dryer. The water column pressure must be regulated at the source (L.P. tank) or an external regulator must be added to each dryer.

Shaded area is stated in metric equivalent

* Drill Measurement Size (D.M.S.) equivalents are as follows:

Natural Gas

#41

=

0.0960” (2.4384 mm).

Liquid Propane Gas

#54

=

0.0550” (1.397 mm).

Piping Connections

ALL components/materials must conform to National Fuel Gas Code Specifications ANSI Z223.1-LATEST EDITION, or in Canada, CAN/CGA-B149.1-M91 (Natural Gas) or CAN/ CGA-B149.2-M91 (Liquid Propane [L.P.] Gas) or LATEST EDITION (for General Installation and Gas Plumbing), as well as local codes and ordinances and must be done by a qualified professional. It is important that gas pressure regulators meet applicable pressure requirements, and that gas meters be rated for the total amount of ALL the appliance Btus being supplied.

12

American Dryer Corp.

113243-1

Image 14
Contents AD-15 Phase Installation Manual ADC Part NoRetain This Manual In a Safe Place For Future Reference Date of Purchase Model no RESELLER’S Name Serial NumbersTable of Contents Latest Edition Safety PrecautionsWhat to do if YOU Smell GAS Specifications FIPLocation Requirements Installation ProceduresUNPACKING/SETTING UP Exhaust Requirements Dryer Enclosure RequirementsFresh AIR Supply Requirements Illus. a Single Dryer VentingHorizontal Venting Multiple Dryer Common Venting Vertical VentingIllus. B Illus. C Important Venting Reminders Electrical InformationGas and Steam Models Only GroundingFor 110V Applications Electrical ConnectionsKLWHRU5HG For 208-230/240V Applications GAS Information Gas SupplyNever Test for Leaks with a Flame Steam InformationVoid the Warranty 0DLPXP6XSSO\ 1RUPDO0LQLPXP6XSSO\ Preoperational Tests GAS and Electric Models the sail switchPreparation for OPERATION/START-UP Preoperational Instructions GAS and Electric Models only Sail SwitchBasket Tumbler Coating Reversing Timer SPIN/DWELL Adjustments MIN RemainSERVICE/PARTS Information Warranty InformationSuggested Cleaning Schedule Routine MaintenanceCleaning Data Label Information Procedure for 113243-1 Dual Timer Manual Reset Burner HI-LIMIT InstructionsPhase Installation Before YOU Start Check Local Codes and PermitsOptional Manual Bypass NON-COIN CoinF.E. System Diagnostics Messages F.E. System Parts Break DownADC 113243 1 2/03/04