American Dryer Corp AD-15 Phase 7 MIN Remain, Reversing Timer SPIN/DWELL Adjustments

Page 20

Mechanical Drop/Rotary Coin Meter or Slide Coin Meter

Insert coin and turn knob (rotary type meter), or for slide meter unit, push in coin chute.

Select Temperature.

Push the “Start” button.

To stop dryer, open the main door.

Non-Coin Models

The light emitting diode (L.E.D.) display reads “READY” (no cycle in progress).

Press the letter on the keyboard (touch pad) corresponding to the cycle desired (i.e., key “D”).

NOTE:

!“0-40” WILL REQUIRE THE “START/ENTER” ￿O

KEY TO BE PRESSED AFTER THE NUMBER IS SELECTED IN ORDER TO ACCEPT THE SELECTION AND START DRYING.

The dryer will then start. (I.E., blower, basket [tumbler], and heat).

The L.E.D. display will read MANUAL DRYING CYCLE D, 00:00

MIN REMAIN.

NOTE:

!Press and hold the “UP ARROW” to view the basket (tumbler) temperature at any time.

The dryer can be stopped at any time by

pressing the “STOP/CLEAR” 2 key, at this time the dryer will go into a cycle pause. If the

“STOP/CLEAR” 2 key is pressed again at this point, the cycle that was in progress will be cancelled and returned to the “READY” state.

Press and hold the “DOWN ARROW” to view the basket (tumbler) RPM.

When the programmed drying time has expired, the Phase 7 non-coin microprocessor controller (computer) will proceed into the Cool Down Cycle.

Once the Cool Down Cycle begins at the end of the heat cycle, the L.E.D. display will read COOL DOWN TEMP

___/___ MINUTES REMAINING. At the end of the heat cycle, the dryer will shut off the heat and continue the fan and basket (tumbler) until the Cool Down Time or temperature is reached.

IMPORTANT:

!For more detailed information regarding the microprocessor controller (computer) on your dryer, refer to the microprocessor user’s manual included with the dryer.

Dual timer dryers

Turn drying timer knob for a time of 20 minutes.

Select “High Temp.”

Push “Push to Start” switch.

To stop dryer, open the main door.

Spin and dwell (stop) times are adjustable at the reversing timer.

REVERSING TIMER SPIN/DWELL ADJUSTMENTS

Timer models have an electronic reversing timer in the electrical service box, which is located in the upper left rear area of the dryer.

Both the Dwell (stop) Time and the basket (tumbler) Spin Time are adjustable by mode selection switches located on the electronic timer (as noted in the illustration below).

63,1$':(//$7LPH9DOXHV￿￿7LPHGMXVWPHQWGMXVWPHQW￿￿￿LQLQ7,0(￿￿6HFRQGV6HFRQGV￿￿￿VKRZQ6723￿￿3RVLWLRQ3RVLWLRQ￿￿￿DUH￿￿7,0(7,0,1*￿￿￿￿￿￿￿￿￿1XPEHUVHFRQG1XPE ￿/(*(1'￿￿￿ ￿￿￿ ￿￿￿￿￿￿￿￿￿￿￿

18

American Dryer Corp.

113243-1

Image 20
Contents AD-15 Phase Installation Manual ADC Part NoRetain This Manual In a Safe Place For Future Reference Date of Purchase Model no RESELLER’S Name Serial NumbersTable of Contents Latest Edition Safety PrecautionsWhat to do if YOU Smell GAS Specifications FIPLocation Requirements Installation ProceduresUNPACKING/SETTING UP Exhaust Requirements Dryer Enclosure RequirementsFresh AIR Supply Requirements Illus. a Single Dryer VentingHorizontal Venting Multiple Dryer Common Venting Vertical VentingIllus. B Illus. C Important Venting Reminders Electrical InformationGas and Steam Models Only GroundingFor 110V Applications Electrical ConnectionsKLWHRU5HG For 208-230/240V Applications GAS Information Gas SupplyNever Test for Leaks with a Flame Steam InformationVoid the Warranty 0DLPXP6XSSO\ 1RUPDO0LQLPXP6XSSO\ Preoperational Tests GAS and Electric Models the sail switchPreparation for OPERATION/START-UP Preoperational Instructions GAS and Electric Models only Sail SwitchBasket Tumbler Coating Reversing Timer SPIN/DWELL Adjustments MIN RemainSERVICE/PARTS Information Warranty InformationSuggested Cleaning Schedule Routine MaintenanceCleaning Data Label Information Procedure for 113243-1 Dual Timer Manual Reset Burner HI-LIMIT InstructionsPhase Installation Before YOU Start Check Local Codes and PermitsOptional Manual Bypass NON-COIN CoinF.E. System Diagnostics Messages F.E. System Parts Break DownADC 113243 1 2/03/04