VERTICAL VENTING
When vertical single
Illus. B
Illus. C
IMPORTANT:
!No more than eight (8) dryers maximum should be connected to one (1) main common duct with a vertical run.
If the length of the duct run or quantity of elbows used exceeds the above noted specifications, the cross section area of the ductwork must be increased in proportion to the number of elbows or duct run added.
IMPORTANT:
!For extended ductwork runs, the cross section area of the duct can only be increased to an extent. For extended ductwork runs, a professional heating, ventilating, and
MULTIPLE DRYER (COMMON) VENTING
If it is not feasible to provide separate exhaust ducts for each dryer, ducts for individual dryers may be channeled into a common main duct. Each dryer is provided with a back draft damper. The individual ducts should enter the bottom or side of the main duct at an angle not more than 45° in the direction of the airflow.
The main common duct may be any shape provided that the minimum
NOTE:
!Distance between dryer single ducts being connected to the main common duct must be a minimum of
Ductwork should be laid out in such a manner where allowances are made at rear area of the dryer for removal of rear service panels or guards.
www.amdry.com | 7 |