Icom MR-1000TTM, MR-1000RTM, EX-2714 Alarm Function, Alarm zone setting, Zone alarm setting

Page 21

ALARM FUNCTION 6

The unit has an alarm function to protect your ship from collisions. If other ships or islands, etc. come into the pre- programmed alarm zone, the function alerts you with an alarm. You can set the desired range and bearing for an alarm zone. While the alarm function is activated, the power save function turns the CRT OFF until an alarm is given, to conserve power.

Alarm zone setting

DSetting and using the alarm function

3/4

(0.25)

 

TVECT 3M

NM CURS\

3143˚T 0397NM

SOG177KT

H UP

HDG2739˚T

 

 

 

IR

 

 

 

ES

GPS

GYRO

qPush [+]/[ ] or [–]/[ ] to select the desired range.

wPush [Ω ≈ Ù Ú] to set the cursor to the starting point of the alarm zone.

ePush and hold [ALM]/[ ] for 1 sec. to enter the alarm zone setting.

• The starting zone appears on the screen. (Fig. 1)

rPush [Ω ≈] to adjust an angle and push [Ù Ú] to set the distance of the alarm zone.

The selected alarm zone appears.

tPush [ALM]/[ ] to fix the alarm zone and activate the alarm function.

• “ALM” appears on the bottom of the screen.

EBL1

VRM1

 

 

EBL2

VRM2

 

Fig. 1

WPT

 

 

CURS 34˚ 3772N 135˚ 3442E

Push

 

 

 

[Ω ≈ Ù Ú]

 

 

 

(0.25)

 

TVECT 3M

 

3/4 NM CURS\

0525˚T 0189NM

 

SOG177KT

H UP

HDG2739˚T

 

 

 

IR

 

 

 

ES

 

“ALM” appears

GPS

 

ALM

GYRO

 

 

EBL1

VRM1

 

EBL2

VRM2

Fig. 2

WPT

 

CURS

34˚ 3772N 135˚ 3442E

The selected alarm zone remains.

yIf a target comes into or goes out of the alarm zone, an alarm beep is emitted.

Push [ALM]/[ ] to cancel the alarm signal and func- tion .

uTo deactivate the alarm function, push [ALM]/[ ].

• “ALM” and alarm zone disappear from the screen.

iTo activate the alarm function again with the same

programmed zone, push [ALM]/[ ].

•“ALM” and pre-programmed alarm zone appears. (Fig. 2)

Using the function with power saver

To activate the power save function, push and hold [TX

(SAVE)]/[ ] for 1 sec. while the alarm function is turned ON.

The CRT display turns OFF.

When a target comes into the alarm zone, an alarm sig- nal is emitted, the CRT display turns ON and the power save function is cancelled.

Zone alarm setting

Target (other ship, etc.)

Alarm zone

Alarm sounds when the target

 

comes into the zone.

Fig. 3

Zone alarm beep is emitted when the target comes into the zone, or the target goes out of the zone. (p. 6)

qPush [MENU]/[ ] several times to call up the FUNCTION menu.

wPush [Ú] until the “ZONE ALARM” section becomes highlighted.

ePush [Ω ≈] to select IN or OUT

• IN : Alarm sounds when the target comes into the zone. (see Fig. 3)

OUT: Alarm sounds when the target goes out of the zone.

17

Image 21
Contents MR-1000R EX-2714Radome type unit Qty System cable OPC-1188 15 m Model Name CRT Display Scanner UnitEX-2780Open array type unit Qty SX-2713/277910 inch CRT display unitWord Definition Rine RadarTable of Contents Radiation Hazard Front panel Panel Description@0DISPLAY Brilliance Switch Brill 9EBL1 VRM1 Switch EBL1 VRM10PARALLEL Index Line Function PI 2HEADING Line OFF Function HL OFFScreen @9MODE Indicator$3HEADING Indicator #9CURSOR Indicator$8OWN Ship Vector Indicator 6TIME Indicator %7TIME IndicatorMenu ATA Automatic Tracking Aid Turning power ON/OFF Checking the installationChecklist Basic OperationBasic operation Rain function SEA functionOFF Center function Stretch function IR functionZoom function Zoom function expands the target to two times normal sizeTrails function Power save functionShip speed indication Bearing settingPosition indication Waypoint indicationUsing the variable range marker Using the fixed ringsDistance and Direction Measurements Distance measurementBearing and Distance measurement Using the EBL and VRMDistance and Direction Measurements Push EBL1 VRM1/ to clear EBL1 and VRM1Measuring the distance and direction between 2 targets Advanced measurementsPush EBL2 VRM2/ to display the EBL2 and VRM2 Push Ù Ú Ω ≈ to move the cursor on the other targetAlarm zone setting Alarm FunctionZone alarm setting Setting and using the alarm functionATA Automatic Tracking Aid ATA menu settingATA operation Plotting marks Course and speed vectorATA Automatic Tracking Aid ATA PlotsBasic Radar Theory Side-lobe echoesIndirect echoes Multiple echoes Minimum rangeBasic Radar Theory Distance resolution Target resolutionDirection resolution Blind and Shadow sectorsConnecting the units Installation and ConnectionsPower source requirement Ground connectionInstalling the display unit Ship’s bow direction Mounting the EX-2714 scanner unitWiring the EX-2714 system cable Scanner unit disassemblyConnect the system cable Mounting the EX-2780 scanner unit Wiring the EX-2780 system cable Beacon Fixing the EX-2780 scanner unitOther Functions All resetAntenna rotation speed Test pattern indicationService MAN Menu Service man menuSelect the language Timing adjustment HDG adjustmentService MAN Menu Range selection SPD adjustmentError Message Error message listMessage Condition Periodic maintenance MaintenanceScanner unit maintenance Display unit maintenanceSpecifications EX-2714 RadomeEX-2780 Open array Display unit SpecificationsBearing Speed Position External Data ListSX-2713/2779 Display mounting bracket template EX-2714 Radome template EX-2780 Open array type template