Icom EX-2714 ATA operation, Plotting marks Course and speed vector, ATA Automatic Tracking Aid

Page 23

ATA (Automatic Tracking Aid)

7

ATA operation

NEW

BRG

CSE

CPA

DIST

SPD

TCPA

Select the target which you want to track on the dis- play.

qPush [Ù Ú Ω ≈] to move the “+” cursor on the de- sired target.

wPush [TARGET]/[ ] for 1 sec. to select the tar- get for tracking.

Identification No.

Bearing Course

Distance Speed

No.10 BRG

305.7T

DIST

11.43NM

CSE

081.3T

SPD

12.3KT

0:20 CPA

5.9NM TCPA

0:50

Closest Point of

Time to Closest Point of

ApproachApproach

Passage of time

Dotted square symbol appears on the cursor.

Target identification number, bearing, distance readout, course (CSE), speed (SPD), CPA and TCPA appear in the information screen.

Timer starts to count the progressing time.

The vector appears on the target, after the progressing time of 20 sec. has passed.

It changes to the circle display of a solid line and a vec- tor display, and tracking operation is decided, after the progressing time of one min. has passed.

When the target which is following disappears, a mark changes to a lozenge and is blinked. A mark disappears after one min..

When a target advances within a setting value, a mark changes to a triangle, blinks and sounds alarm sound. Alarm sound will be cancelled if one of key is pushed.

To cancel the target setting, move the cursor on the tar-

get, then push [TARGET]/[ ] for 1 sec.

[TARGET]/[ ] is pushed for changing the display of EBL/VRM etc. to target information.

In order to choose target which displays information,

cursor is united with target and [TARGET]/[ ] is pushed.

Plotting marks

Course and speed vector

Target’s predicted positon

Vector

Vector time

Current position

There are 5 kinds of plotting marks.

: Selected, uncalculated mark.

: Selected, calculated mark.

: Normal, calculated mark.

:CPA/TCPA alarm mark. The target is close to within a minimum range and time. Alarm emit indicator. Push [TAR-

GET]/[ ] to cancel the alarm.

:When the tracking of a target disap- pears.

The vector indicates the target’s predicted, true or rel- ative course and speed.

Vector time may change depending on the TRAIL TIME set- ting. (see VIDEO menu, p. 6)

The tip of the vector shows the target’s predicted position after a certain time, which has been selected in the “TRAIL TIME”.

19

Image 23
Contents MR-1000R SX-2713/277910 inch CRT display unit Model Name CRT Display Scanner UnitEX-2714Radome type unit Qty System cable OPC-1188 15 m EX-2780Open array type unit QtyWord Definition Rine RadarTable of Contents Radiation Hazard Front panel Panel Description2HEADING Line OFF Function HL OFF 9EBL1 VRM1 Switch EBL1 VRM1@0DISPLAY Brilliance Switch Brill 0PARALLEL Index Line Function PIScreen @9MODE Indicator6TIME Indicator %7TIME Indicator #9CURSOR Indicator$3HEADING Indicator $8OWN Ship Vector IndicatorMenu ATA Automatic Tracking Aid Basic Operation Checking the installationTurning power ON/OFF ChecklistBasic operation OFF Center function Rain functionSEA function Zoom function expands the target to two times normal size IR functionStretch function Zoom functionTrails function Power save functionWaypoint indication Bearing settingShip speed indication Position indicationDistance measurement Using the fixed ringsUsing the variable range marker Distance and Direction MeasurementsPush EBL1 VRM1/ to clear EBL1 and VRM1 Using the EBL and VRMBearing and Distance measurement Distance and Direction MeasurementsPush Ù Ú Ω ≈ to move the cursor on the other target Advanced measurementsMeasuring the distance and direction between 2 targets Push EBL2 VRM2/ to display the EBL2 and VRM2Setting and using the alarm function Alarm FunctionAlarm zone setting Zone alarm settingATA Automatic Tracking Aid ATA menu settingATA Automatic Tracking Aid ATA operationPlotting marks Course and speed vector ATA PlotsIndirect echoes Basic Radar TheorySide-lobe echoes Basic Radar Theory Multiple echoesMinimum range Blind and Shadow sectors Target resolutionDistance resolution Direction resolutionGround connection Installation and ConnectionsConnecting the units Power source requirementInstalling the display unit Ship’s bow direction Mounting the EX-2714 scanner unitConnect the system cable Wiring the EX-2714 system cableScanner unit disassembly Mounting the EX-2780 scanner unit Wiring the EX-2780 system cable Beacon Fixing the EX-2780 scanner unitTest pattern indication All resetOther Functions Antenna rotation speedSelect the language Service MAN MenuService man menu Service MAN Menu Timing adjustmentHDG adjustment Range selection SPD adjustmentMessage Condition Error MessageError message list Display unit maintenance MaintenancePeriodic maintenance Scanner unit maintenanceEX-2780 Open array SpecificationsEX-2714 Radome Display unit SpecificationsBearing Speed Position External Data ListSX-2713/2779 Display mounting bracket template EX-2714 Radome template EX-2780 Open array type template