Icom MR-1000RTM, MR-1000TTM, EX-2714 Timing adjustment, HDG adjustment, Service MAN Menu

Page 37

TIMING adjustment

The system cable length affects the sweep timing. When the cable length adjustment is not correct, a straight target is shown as a curved echo. Thus, cable length adjustment is necessary.

qPosition your boat near a straight target such as breakwater, wharf, etc.

wPush [–]/[ ] several times to select 18 or 14 NM range.

SERVICE MAN MENU 11

ePush [TX (SAVE)]/[ ] to display the target on the screen.

rPush [MENU]/[ ], [Ú] and [] several times to display the “SERVICE MAN” menu.

tPush [Ú] until the “TIMING ADJ.” section becomes highlighted.

yPush [Ω ≈] to adjust the echo until it becomes straight. (see below)

u Push [MENU]/[ ] to return to the normal screen.

Proper adjustment

Improper, pulling inward

Improper, pushing outward

HDG adjustment

If the heading marker line differs from the exact bow direction, correct the heading marker line as follows. This function may be helpful when the scanner has not been mounted exactly in the direction of the bow.

1 T.V E C T

NM C U R S 000 . 0 ˚ R 0.000N M

S O G

H UP

HDG

IR

ES

Angle of difference

qLine up the bow of the boat with an identifiable tar- get.

wPush [TX (SAVE)]/[ ] to display the target on the screen.

ePush [MENU]/[ ], [Ú] and [] several times to display the “SERVICE MAN” menu.

rPush [Ú] until the “HDG ADJ.” section becomes highlighted.

tPush [Ω ≈] to adjust, until the target matches the heading marker. (the difference can be read out on the menu screen)

yPush [MENU]/[ ] to return to the normal screen.

1 T.VECT

NM CURS 000 . 0 ˚ R 0.000NM

SOG

H UP

HDG

IR

ES

Push [Ω ≈]

 

 

 

SERVICE MAN

 

 

 

 

 

 

 

SERVICE MAN

 

 

 

 

 

ENGLISH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENGLISH

 

 

 

 

 

 

 

 

 

 

 

 

 

TIMING ADJ.

 

 

 

 

 

OUTPUT VOLTAGE 3 0 . 0

TIMING ADJ.

 

 

 

 

 

OUTPUT VOLTAGE 3 0 . 0

 

0.0˚

 

10.0˚

HDG ADJ.

 

 

HV

 

 

 

 

 

 

3 4 0

HDG ADJ.

 

 

HV

 

 

 

 

 

 

3 4 0

SPD ADJ.

2 4 0 0 0

 

MONITOR

 

7 5

SPD ADJ.

2 4 0 0 0

 

MONITOR

 

7 5

SETUP MEMORY

 

 

 

 

 

HEATER

 

0 . 5 5

SETUP MEMORY

 

 

 

 

 

HEATER

 

0 . 5 5

 

 

 

 

 

 

 

MG

 

 

 

 

 

3 . 0

 

 

 

 

 

 

 

MG

 

 

 

 

 

3 . 0

 

 

 

 

 

 

 

TX TIME

 

 

 

 

 

 

 

 

 

 

 

TX TIME

 

 

 

 

RANGE

 

 

 

 

 

 

 

 

 

 

 

5 7 3 1 . 0 H

RANGE

 

 

 

 

 

 

 

 

 

 

 

5 7 3 1 . 0 H

 

1/8

 

 

3/4

 

2

 

6

 

16

 

36

 

 

1/8

 

 

3/4

 

2

 

6

 

16

 

36

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1/4

 

1

 

3

 

8

 

24

48

 

 

 

 

1/4

 

1

 

3

 

8

 

24

48

 

 

 

 

1/2

 

1.5

 

4

 

12

 

32

 

 

 

 

 

 

1/2

 

1.5

 

4

 

12

 

32

 

 

 

33

Image 37
Contents MR-1000R EX-2714Radome type unit Qty System cable OPC-1188 15 m Model Name CRT Display Scanner UnitEX-2780Open array type unit Qty SX-2713/277910 inch CRT display unitWord Definition Rine RadarTable of Contents Radiation Hazard Front panel Panel Description@0DISPLAY Brilliance Switch Brill 9EBL1 VRM1 Switch EBL1 VRM10PARALLEL Index Line Function PI 2HEADING Line OFF Function HL OFFScreen @9MODE Indicator$3HEADING Indicator #9CURSOR Indicator$8OWN Ship Vector Indicator 6TIME Indicator %7TIME IndicatorMenu ATA Automatic Tracking Aid Turning power ON/OFF Checking the installationChecklist Basic OperationBasic operation SEA function Rain functionOFF Center function Stretch function IR functionZoom function Zoom function expands the target to two times normal sizeTrails function Power save functionShip speed indication Bearing settingPosition indication Waypoint indicationUsing the variable range marker Using the fixed ringsDistance and Direction Measurements Distance measurementBearing and Distance measurement Using the EBL and VRMDistance and Direction Measurements Push EBL1 VRM1/ to clear EBL1 and VRM1Measuring the distance and direction between 2 targets Advanced measurementsPush EBL2 VRM2/ to display the EBL2 and VRM2 Push Ù Ú Ω ≈ to move the cursor on the other targetAlarm zone setting Alarm FunctionZone alarm setting Setting and using the alarm functionATA Automatic Tracking Aid ATA menu settingPlotting marks Course and speed vector ATA operationATA Automatic Tracking Aid ATA PlotsSide-lobe echoes Basic Radar TheoryIndirect echoes Minimum range Multiple echoesBasic Radar Theory Distance resolution Target resolutionDirection resolution Blind and Shadow sectorsConnecting the units Installation and ConnectionsPower source requirement Ground connectionInstalling the display unit Ship’s bow direction Mounting the EX-2714 scanner unitScanner unit disassembly Wiring the EX-2714 system cableConnect the system cable Mounting the EX-2780 scanner unit Wiring the EX-2780 system cable Beacon Fixing the EX-2780 scanner unitOther Functions All resetAntenna rotation speed Test pattern indicationService man menu Service MAN MenuSelect the language HDG adjustment Timing adjustmentService MAN Menu Range selection SPD adjustmentError message list Error MessageMessage Condition Periodic maintenance MaintenanceScanner unit maintenance Display unit maintenanceEX-2714 Radome SpecificationsEX-2780 Open array Display unit SpecificationsBearing Speed Position External Data ListSX-2713/2779 Display mounting bracket template EX-2714 Radome template EX-2780 Open array type template