Icom MR-1000TTM, MR-1000RTM, EX-2714 instruction manual IR function, Stretch function, Zoom function

Page 15

BASIC OPERATION 4

IR function

Radar interference may appear when another ship’s radar is operating on the same frequency band in close proximity. The IR function can eliminate this type of interference. (p. 6)

q Push [MENU]/[] to call up VIDEO menu.

w Push [Ú] until the “IR” section becomes highlighted. e Push [Ω ≈] to select IR function 1, 2 or OFF.

• “IR” appears in the upper right of the screen, when the function is activated.

Radar interference

With IR function ON

STRETCH function

The blips can be magnified electronically for easier viewing of small targets. (p. 6)

q Push [MENU]/[ ] to open the VIDEO menu.

w Push [Ú] to select “STRETCH”, then push [] to turn the function ON.

NOTE: Turn OFF this function during normal opera- tion.

Normal screen

With STRETCH ON

ZOOM function

The ZOOM function expands the target to two times normal size.

• This function is available up to a 24 NM range or shorter ex- cept 18 NM.

 

 

q Push [Ù Ú Ω ≈] to move the cursor to the desired

 

 

target.

 

 

 

w Push [TARGET]/[ ] and [TRAILS]/[

] si-

 

 

multaneously to toggle the ZOOM function ON and

 

 

OFF.

 

Normal screen

With ZOOM function ON

• “ZOOM” appears in the lower right of the screen.

 

11

Image 15
Contents MR-1000R SX-2713/277910 inch CRT display unit Model Name CRT Display Scanner UnitEX-2714Radome type unit Qty System cable OPC-1188 15 m EX-2780Open array type unit QtyWord Definition Rine RadarTable of Contents Radiation Hazard Front panel Panel Description2HEADING Line OFF Function HL OFF 9EBL1 VRM1 Switch EBL1 VRM1@0DISPLAY Brilliance Switch Brill 0PARALLEL Index Line Function PIScreen @9MODE Indicator6TIME Indicator %7TIME Indicator #9CURSOR Indicator$3HEADING Indicator $8OWN Ship Vector IndicatorMenu ATA Automatic Tracking Aid Basic Operation Checking the installationTurning power ON/OFF ChecklistBasic operation Rain function SEA functionOFF Center function Zoom function expands the target to two times normal size IR functionStretch function Zoom functionTrails function Power save functionWaypoint indication Bearing settingShip speed indication Position indicationDistance measurement Using the fixed ringsUsing the variable range marker Distance and Direction MeasurementsPush EBL1 VRM1/ to clear EBL1 and VRM1 Using the EBL and VRMBearing and Distance measurement Distance and Direction MeasurementsPush Ù Ú Ω ≈ to move the cursor on the other target Advanced measurementsMeasuring the distance and direction between 2 targets Push EBL2 VRM2/ to display the EBL2 and VRM2Setting and using the alarm function Alarm FunctionAlarm zone setting Zone alarm settingATA Automatic Tracking Aid ATA menu settingATA operation Plotting marks Course and speed vectorATA Automatic Tracking Aid ATA PlotsBasic Radar Theory Side-lobe echoesIndirect echoes Multiple echoes Minimum rangeBasic Radar Theory Blind and Shadow sectors Target resolutionDistance resolution Direction resolutionGround connection Installation and ConnectionsConnecting the units Power source requirementInstalling the display unit Ship’s bow direction Mounting the EX-2714 scanner unitWiring the EX-2714 system cable Scanner unit disassemblyConnect the system cable Mounting the EX-2780 scanner unit Wiring the EX-2780 system cable Beacon Fixing the EX-2780 scanner unitTest pattern indication All resetOther Functions Antenna rotation speedService MAN Menu Service man menuSelect the language Timing adjustment HDG adjustmentService MAN Menu Range selection SPD adjustmentError Message Error message listMessage Condition Display unit maintenance MaintenancePeriodic maintenance Scanner unit maintenanceSpecifications EX-2714 RadomeEX-2780 Open array Display unit SpecificationsBearing Speed Position External Data ListSX-2713/2779 Display mounting bracket template EX-2714 Radome template EX-2780 Open array type template