Icom MR-1000RTM, MR-1000TTM, EX-2714 instruction manual Fixing the EX-2780 scanner unit, Beacon

Page 34

9 INSTALLATION AND CONNECTIONS

Fixing the EX-2780 scanner unit

qPut the scanner unit*1 on the stay, then fix the an- tenna rotor with installation bolts of 8 mm (5/16 in) in diameter, with flat and dish washers and a seal- ing washer. Be sure to keep the direction of the dish washer correct as shown in the diagram*2. (Fig. 4)

wApply lubricant specified below or an equivalent one to the motor bearing*3, if required.

• Manufacture: ESSO

Type:

BEACON 325

eConnect the grounding wire to the ground plate with the supplied terminal if required. (Fig. 5)

*3Lubricant spot

Fig. 4

NOTE: When using the optional system cable.

Peel the outer sheath of the system cable when using the optional system cable OPC-1078.

BE CAREFUL ! DO NOT cut the inner shield wire when peeling the outer sheath.

18±2

410±5

To the display

To the scanner

Peel the sheath

(Unit: mm)

*1Scanner unit

Stay

*2

Sealing

 

washer

Keep in this direction

Installation bolt

Fig. 5

30

Image 34 Contents
MR-1000R EX-2780Open array type unit Qty Model Name CRT Display Scanner UnitEX-2714Radome type unit Qty System cable OPC-1188 15 m SX-2713/277910 inch CRT display unitRine Radar Word DefinitionTable of Contents Radiation Hazard Panel Description Front panel0PARALLEL Index Line Function PI 9EBL1 VRM1 Switch EBL1 VRM1@0DISPLAY Brilliance Switch Brill 2HEADING Line OFF Function HL OFF@9MODE Indicator Screen$8OWN Ship Vector Indicator #9CURSOR Indicator$3HEADING Indicator 6TIME Indicator %7TIME IndicatorMenu ATA Automatic Tracking Aid Checklist Checking the installationTurning power ON/OFF Basic OperationBasic operation SEA function Rain functionOFF Center function Zoom function IR functionStretch function Zoom function expands the target to two times normal sizePower save function Trails functionPosition indication Bearing settingShip speed indication Waypoint indicationDistance and Direction Measurements Using the fixed ringsUsing the variable range marker Distance measurementDistance and Direction Measurements Using the EBL and VRMBearing and Distance measurement Push EBL1 VRM1/ to clear EBL1 and VRM1Push EBL2 VRM2/ to display the EBL2 and VRM2 Advanced measurementsMeasuring the distance and direction between 2 targets Push Ù Ú Ω ≈ to move the cursor on the other targetZone alarm setting Alarm FunctionAlarm zone setting Setting and using the alarm functionATA menu setting ATA Automatic Tracking AidPlotting marks Course and speed vector ATA operationATA Automatic Tracking Aid Plots ATASide-lobe echoes Basic Radar TheoryIndirect echoes Minimum range Multiple echoesBasic Radar Theory Direction resolution Target resolutionDistance resolution Blind and Shadow sectorsPower source requirement Installation and ConnectionsConnecting the units Ground connectionInstalling the display unit Mounting the EX-2714 scanner unit Ship’s bow directionScanner unit disassembly Wiring the EX-2714 system cableConnect the system cable Mounting the EX-2780 scanner unit Wiring the EX-2780 system cable Fixing the EX-2780 scanner unit BeaconAntenna rotation speed All resetOther Functions Test pattern indicationService man menu Service MAN MenuSelect the language HDG adjustment Timing adjustmentService MAN Menu SPD adjustment Range selectionError message list Error MessageMessage Condition Scanner unit maintenance MaintenancePeriodic maintenance Display unit maintenanceEX-2714 Radome SpecificationsEX-2780 Open array Specifications Display unitExternal Data List Bearing Speed PositionSX-2713/2779 Display mounting bracket template EX-2714 Radome template EX-2780 Open array type template