Icom MR-1000TTM Distance and Direction Measurements, Distance measurement, Using the fixed rings

Page 18

5 DISTANCE AND DIRECTION MEASUREMENTS

Distance measurement

TYPE

DESCRIPTION

 

Displays fixed rings.

RING

Suitable for rough estimations from your

 

own ship to any target.

 

 

 

Displays a variable range marker and ac-

 

tivated by the [Ù Ú] for the range marker

VRM1

selector.

 

Suitable for accurate measurements from

 

your own ship to a target.

 

 

 

Normally functions the same as VRM1.

 

When the VRM1 and EBL1 selects a tar-

VRM2

get, the center of VRM2 appears at the

intersection point.

 

 

Suitable for accurate measurements from

 

target to target.

 

 

Two measurement procedures are available with this radar. Operating them separately or jointly is possible.

The distance unit, nautical miles (NM) or kilometers (KM) is selected in the FUNCTION menu (p. 6).

DUsing the fixed rings

Ring range readout

1

(0.25)

 

 

T.V E C T

NM C U R S

014 . 6˚ T

0.9 0 0 N M

SOG 0 . 0KT

H UP

HDG

IR

ES

Fixed ring

E B L 1

 

 

V R M 1

E B L 2

 

 

V R M 2

 

WPT

 

 

 

 

CURS

3 4 ˚ 3 7 . 7 2 N 1 3 5 ˚ 3 4 .4 2 E

qPush [MENU]/[ ] several times to call up the FUNCTION menu.

wPush [Ú] until the “RING” section becomes high- lighted.

ePush [≈] to select RING function ON and display the fixed ring.

The interval range appears on the right of the screen range readout.

The ring range is fixed depending on the screen range. (See below.)

rPush [MENU]/[ ] several times to exit the menu. t To clear the fixed rings, push [] to select OFF in

step e above.

Range (nm)

18

14

12

34

1

1.5

2

3

4

6

8

12

16

24

32

36

48*

Ring (nm)

120

120

110

14

14

14

12

12

1

1

2

2

4

4

8

6

8

 

2

5

5

3

4

6

4

6

4

6

4

6

4

6

4

6

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: When the screen is shifted, the number of rings may differ. *Available for the MR-1000TII only.

DUsing the variable range marker

q Push [EBL1 (VRM1)]/[ ] to display the VRM1 and EBL1; then, push [Ù Ú] to set the marker.

• The range between the ship and the target is indicated in the VRM readouts.

w Push [EBL2 (VRM2)]/[] to display the VRM2 and EBL2; then, push [Ù Ú] to set the marker.

• The range between the ship and the target is indicated in the VRM readouts.

• When the VRM1 and EBL1 are displayed, the center of VRM2 appears at the intersection point of the VRM1 and EBL1.

• The VRM2 disappears when [EBL1 (VRM1)] is pushed.

e Push [EBL1 (VRM1)]/[ ] to exit the menu display.

14

Image 18 Contents
MR-1000R EX-2780Open array type unit Qty Model Name CRT Display Scanner UnitEX-2714Radome type unit Qty System cable OPC-1188 15 m SX-2713/277910 inch CRT display unitRine Radar Word DefinitionTable of Contents Radiation Hazard Panel Description Front panel0PARALLEL Index Line Function PI 9EBL1 VRM1 Switch EBL1 VRM1@0DISPLAY Brilliance Switch Brill 2HEADING Line OFF Function HL OFF@9MODE Indicator Screen$8OWN Ship Vector Indicator #9CURSOR Indicator$3HEADING Indicator 6TIME Indicator %7TIME IndicatorMenu ATA Automatic Tracking Aid Checklist Checking the installationTurning power ON/OFF Basic OperationBasic operation Rain function SEA function OFF Center function Zoom function IR functionStretch function Zoom function expands the target to two times normal sizePower save function Trails functionPosition indication Bearing settingShip speed indication Waypoint indicationDistance and Direction Measurements Using the fixed ringsUsing the variable range marker Distance measurementDistance and Direction Measurements Using the EBL and VRMBearing and Distance measurement Push EBL1 VRM1/ to clear EBL1 and VRM1Push EBL2 VRM2/ to display the EBL2 and VRM2 Advanced measurementsMeasuring the distance and direction between 2 targets Push Ù Ú Ω ≈ to move the cursor on the other targetZone alarm setting Alarm FunctionAlarm zone setting Setting and using the alarm functionATA menu setting ATA Automatic Tracking AidATA operation Plotting marks Course and speed vectorATA Automatic Tracking Aid Plots ATABasic Radar Theory Side-lobe echoesIndirect echoes Multiple echoes Minimum rangeBasic Radar Theory Direction resolution Target resolutionDistance resolution Blind and Shadow sectorsPower source requirement Installation and ConnectionsConnecting the units Ground connectionInstalling the display unit Mounting the EX-2714 scanner unit Ship’s bow directionWiring the EX-2714 system cable Scanner unit disassemblyConnect the system cable Mounting the EX-2780 scanner unit Wiring the EX-2780 system cable Fixing the EX-2780 scanner unit BeaconAntenna rotation speed All resetOther Functions Test pattern indicationService MAN Menu Service man menuSelect the language Timing adjustment HDG adjustmentService MAN Menu SPD adjustment Range selectionError Message Error message listMessage Condition Scanner unit maintenance MaintenancePeriodic maintenance Display unit maintenanceSpecifications EX-2714 RadomeEX-2780 Open array Specifications Display unitExternal Data List Bearing Speed PositionSX-2713/2779 Display mounting bracket template EX-2714 Radome template EX-2780 Open array type template