Icom EX-2714, MR-1000TTM, MR-1000RTM instruction manual ATA Automatic Tracking Aid

Page 11

ATA (Automatic Tracking Aid)

MENU 3

INT. SETTING

 

A T A MENU

 

 

 

 

A T A

 

 

OFF

No.DISP

 

 

OFF

VECT

 

 

TRUE

OWN VECT

 

 

 

 

 

OFF

ALARM

 

 

 

 

 

OFF

CPA LIMIT

 

 

1.0NM

TCPA LIMIT

 

 

1 MIN

ON

SEL

REL

ON ON

ALL

MAG VAR

BRG INPUT SPD INPUT TX INH START TX INH ANGLE SAVE TIME SYMBOL

CHARACTER KEY ILLUM

INT. SETTING

 

AUTO

MANUAL

 

 

 

 

 

 

 

 

7.2˚ W

 

NMEA

 

N+1

AUX

GPS

 

 

 

 

 

 

 

LOG

 

 

GPS

 

 

 

 

 

 

 

0˚

 

 

 

 

 

 

 

1M

0˚

 

 

15M

30M

 

 

 

6M

 

 

 

2

3

 

 

 

 

1

 

 

 

 

 

1

 

 

 

3

 

 

 

BRILL

2

 

 

 

1

 

2

3

 

4

 

 

DATA

• OFF

: Turn the ATA function OFF.

• ON

: Turn the ATA function ON.

DNo.DISP

• OFF

: Non display any mark number.

• Sel

: Display the selected mark number

 

only.

• ALL

: Display all mark numbers.

DVECT

• TRUE

: Select the true vector mode.

• REL

: Select the relative vector mode.

DOWN VECT

• OFF

: Non display the own ship vector.

• ON

: Display your own ship’s vector.

DALARM (CPA/TCPA)

• OFF

: Turn the alarm function OFF.

• ON

: Turn the alarm function ON.

DCPA* LIMIT

0.1 to 10.0NM : Set the CPA (Closest Point of Ap- proach) limit with [Ω ≈].

DTCPA* LIMIT

• 1 to 60MIN : Set the TCPA (Time to CPA) limit time with [Ω ≈].

*CPA/TCPA: Closest Point of Approach and Time to Clos- est Point of Approach limit is defined by the observer to given warning when a target or targets are close to within those limits from your own ship.

DMAG VAR

• AUTO

: Revise magnetic variation automatically.

 

NOTE: NMEA data is required. NEVER select

 

“AUTO” without NMEA data, incorrect varia-

 

tion data may entered. (p. 39)

MANUAL : Revise magnetic variation manually.

Push [≈] to select [MANUAL], then push [Ú]. Set the revise value with [Ω ≈]. Push [Ú] or [MENU] to abort the menu.

DBRG INPUT

• NMEA : NMEA0183 bearing data format.

N+1 : N+1 data format.

• AUX

: Other format.

• GPS

: Reads NMEA0183 COG format data as

 

HDG format.

DSPD INPUT

• GPS

: Use the GPS NMEA speed data.

• LOG

: Use the speed sensor data.

DTX INH START

0 to 359° : Push [Ω ≈] to enter the start point of the TX inhibit area.

DTX INH ANGLE

0 to 90° : Push [Ω ≈] to enter the TX inhibit area.

DSAVE TIME

1M, 6M, 15M or 30M

:Select the stand by time during save mode.

* The radar for TX interval scan is fixed at 10 revolutions.

DSYMBOL

1/2/3 : Select the symbol brightness.

DCHARACTER

1/2/3 : Select the character brightness.

DKEY ILLUM

1/2/3/4 : Select the key illumination brightness.

7

Image 11
Contents MR-1000R SX-2713/277910 inch CRT display unit Model Name CRT Display Scanner UnitEX-2714Radome type unit Qty System cable OPC-1188 15 m EX-2780Open array type unit QtyWord Definition Rine RadarTable of Contents Radiation Hazard Front panel Panel Description2HEADING Line OFF Function HL OFF 9EBL1 VRM1 Switch EBL1 VRM1@0DISPLAY Brilliance Switch Brill 0PARALLEL Index Line Function PIScreen @9MODE Indicator6TIME Indicator %7TIME Indicator #9CURSOR Indicator$3HEADING Indicator $8OWN Ship Vector IndicatorMenu ATA Automatic Tracking Aid Basic Operation Checking the installationTurning power ON/OFF ChecklistBasic operation OFF Center function Rain functionSEA function Zoom function expands the target to two times normal size IR functionStretch function Zoom functionTrails function Power save functionWaypoint indication Bearing settingShip speed indication Position indicationDistance measurement Using the fixed ringsUsing the variable range marker Distance and Direction MeasurementsPush EBL1 VRM1/ to clear EBL1 and VRM1 Using the EBL and VRMBearing and Distance measurement Distance and Direction MeasurementsPush Ù Ú Ω ≈ to move the cursor on the other target Advanced measurementsMeasuring the distance and direction between 2 targets Push EBL2 VRM2/ to display the EBL2 and VRM2Setting and using the alarm function Alarm FunctionAlarm zone setting Zone alarm settingATA Automatic Tracking Aid ATA menu settingATA Automatic Tracking Aid ATA operationPlotting marks Course and speed vector ATA PlotsIndirect echoes Basic Radar TheorySide-lobe echoes Basic Radar Theory Multiple echoesMinimum range Blind and Shadow sectors Target resolutionDistance resolution Direction resolutionGround connection Installation and ConnectionsConnecting the units Power source requirementInstalling the display unit Ship’s bow direction Mounting the EX-2714 scanner unitConnect the system cable Wiring the EX-2714 system cableScanner unit disassembly Mounting the EX-2780 scanner unit Wiring the EX-2780 system cable Beacon Fixing the EX-2780 scanner unitTest pattern indication All resetOther Functions Antenna rotation speedSelect the language Service MAN MenuService man menu Service MAN Menu Timing adjustmentHDG adjustment Range selection SPD adjustmentMessage Condition Error MessageError message list Display unit maintenance MaintenancePeriodic maintenance Scanner unit maintenanceEX-2780 Open array SpecificationsEX-2714 Radome Display unit SpecificationsBearing Speed Position External Data ListSX-2713/2779 Display mounting bracket template EX-2714 Radome template EX-2780 Open array type template