9 INSTALLATION AND CONNECTIONS

Mounting the EX-2714 scanner unit

WARNING: BE SURE [POWER] is OFF when- ever you are working with the scanner unit.

The scanner unit is designed to be weatherproof and completely watertight. Select a place for installation which meets the following important conditions.

qThe scanner unit must be near the boat’s center line and have a good view in every direction. Be sure there are no objects in the surrounding area which will intercept the scanning beam.

wKEEP the scanner unit away from any smoke- stacks. Smoke can damage the unit.

eWhen the boat is equipped with a radio directional finder (RDF) system, keep the scanner unit at least 2 m (6.6 ft) away from any RDF antenna.

Radiation from the scanner unit can affect the measure- ment data of RDF equipment.

rThe unit should be placed as high as possible on the boat to obtain best performance with maximum range.

tIf you install two or more radar in one boat, install one above, and one below.

yThe mounting surface must be parallel with the boat’s waterline.

uIf the height is insufficient to install the scanner unit, build a special frame for installation.

DMounting

qDrill four holes of 12 mm (12 in) in diameter using the template.

wIf the mounting surface or platform is metal, apply sealing compound around the holes to prevent cor- rosion and to waterproof the unit.

eFix the scanner unit to the selected position with bolts of 10 mm (38 in) in diameter, with flat and spring washers. The supplied bolts are two lengths: 25 mm (1 in) or 50 mm (2 in).

CAUTION: SECURE the four bolts tightly.

Ship’s bow direction

Ship’s bow direction

243 (9916)

607 (232932)

90.5 (3916) 90.5 (3916)

45.5 (11316) 150.5 (51516)

Unit: mm (in)

26

Image 30
Contents MR-1000R EX-2780Open array type unit Qty Model Name CRT Display Scanner UnitEX-2714Radome type unit Qty System cable OPC-1188 15 m SX-2713/277910 inch CRT display unitRine Radar Word DefinitionTable of Contents Radiation Hazard Panel Description Front panel0PARALLEL Index Line Function PI 9EBL1 VRM1 Switch EBL1 VRM1@0DISPLAY Brilliance Switch Brill 2HEADING Line OFF Function HL OFF@9MODE Indicator Screen$8OWN Ship Vector Indicator #9CURSOR Indicator$3HEADING Indicator 6TIME Indicator %7TIME IndicatorMenu ATA Automatic Tracking Aid Checklist Checking the installationTurning power ON/OFF Basic OperationBasic operation Rain function SEA functionOFF Center function Zoom function IR functionStretch function Zoom function expands the target to two times normal sizePower save function Trails functionPosition indication Bearing settingShip speed indication Waypoint indicationDistance and Direction Measurements Using the fixed ringsUsing the variable range marker Distance measurementDistance and Direction Measurements Using the EBL and VRMBearing and Distance measurement Push EBL1 VRM1/ to clear EBL1 and VRM1Push EBL2 VRM2/ to display the EBL2 and VRM2 Advanced measurementsMeasuring the distance and direction between 2 targets Push Ù Ú Ω ≈ to move the cursor on the other targetZone alarm setting Alarm FunctionAlarm zone setting Setting and using the alarm functionATA menu setting ATA Automatic Tracking AidATA operation Plotting marks Course and speed vectorATA Automatic Tracking Aid Plots ATABasic Radar Theory Side-lobe echoesIndirect echoes Multiple echoes Minimum rangeBasic Radar Theory Direction resolution Target resolutionDistance resolution Blind and Shadow sectorsPower source requirement Installation and ConnectionsConnecting the units Ground connectionInstalling the display unit Mounting the EX-2714 scanner unit Ship’s bow directionWiring the EX-2714 system cable Scanner unit disassemblyConnect the system cable Mounting the EX-2780 scanner unit Wiring the EX-2780 system cable Fixing the EX-2780 scanner unit BeaconAntenna rotation speed All resetOther Functions Test pattern indicationService MAN Menu Service man menuSelect the language Timing adjustment HDG adjustmentService MAN Menu SPD adjustment Range selectionError Message Error message listMessage Condition Scanner unit maintenance MaintenancePeriodic maintenance Display unit maintenanceSpecifications EX-2714 RadomeEX-2780 Open array Specifications Display unitExternal Data List Bearing Speed PositionSX-2713/2779 Display mounting bracket template EX-2714 Radome template EX-2780 Open array type template