This catalog is out of date, see note on page 3
Designation | Order No. | Release | Remarks |
| of module |
|
|
|
|
|
|
Binary calculation modules |
|
|
|
Binary calculation module | 6DS1 | ≥ 8 | 16) 24) |
|
| SW:08 |
|
Binary/analog calculation | 6DS1 | ≥ 1 | 16) 24) |
module (max. 31 channels) |
| SW:3 |
|
Binary extension | 6DS1 | ≥ 2 | 15) |
Analog extension | 6DS1 | ≥ 1 | 15) |
Binary extension (for | 6DS1 | ≥ 1 |
|
6DS1 |
|
|
|
Coupling modules |
|
|
|
|
|
|
|
6DS1 | ≥ 8 |
| |
6DS1 | ≥ 8 |
| |
S5 coupling, serial | 6DS1 | ≥ 3 | 1) 24) |
|
| SW: 1 |
|
S5 coupling (expansion unit) | 6DS1 | ≥ 4 |
|
S5 coupling, serial | 6DS1 | ≥ 1 |
|
S7 coupling, serial | 6DS1 | ≥ 1 | 22) 24) |
MODBUS coupling | 6DS1 | ≥ 1 | 3) 24) |
(on request) | with | SW=5 |
|
I/O bus remote coupling | 6DS1 | ≥ 5 | 1) 12) |
AS - I/O bus - ES 100 K |
|
|
|
S5 coupling, serial, | 6DS1 | ≥ 4 |
|
ET 100, EU / I/Os, |
|
|
|
|
|
| |
Coupling of external com- | 6DS1 | ≥ 5 | 19) 20) |
puter via CS 275 / |
|
|
|
CP 581 TM interface modules |
|
|
|
|
|
|
|
CP 581 TM communications | 6DS1 | ≥ 1 | 2) 19) |
module | with S5KE, S5KS | SW: ... | 20) 21) |
CP 581 | 6DS1 | ≥ 1 | 2) 19) |
| with S5KE, S5KS | SW: ... | 20) 21) |
CP 581 TM FUZZY | 6DS1 | ≥ 1 | 2) 19) |
| with S5KE, S5KS | SW: ... | 20) 21) |
|
|
| 23) 24) |
|
|
|
|
*) in certain circumstances there are some special features for these modules, please ask your Siemens contact
Migration of existing systems
Configuring lists
Migratable TELEPERM M modules in AS 488/TM
Explanations for the column „Remarks“
1)Earlier release versions not permissible!
2)Special product
3)Not a standard product, no system test carried out
5)Application only without interrupt!
6)No application as common alarm module (SF 61)
7)Approved for common alarm modules, the latest product release is required.
8)Note current balance of subrack:
max. 4 A per module, max. 16 A per subrack
9)Combination modules for use in TELEPERM M standard systems and in TELEPERM ME systems. Application in AS 235/488 extension units only as TELEPERM ME module with slot addressing.
11)Note: Release 3 is not allowed!
12)Cycle time in TPM 478 for processing of modules in ES 100 K can be delayed (dependent on the cable length); coupling modules are used at best in the basic unit.
13)Application in ES 100 K not allowed (timing)
14)Connection of transmitters with
15)Module only functions together with 6DS1
16)Only alarm function
17)Module only functions together with 6DS1 713 or 6DS1 731.
19)A maximum of 1 module of type Typ
20)Application in ES 100 K not allowed (5 V power)
21)Hardware/software releases on request: Siemens Karlsruhe,
I&S IT PS KHE3,
D-76181 Karlsruhe, Germany
22)S7 coupling with 3964 R / RK 512 procedure, SEND/RECEIVE, SIMATIC S5 analog value format
23)only CP 581/TM versions with S5Kx drivers can be used. Power balance of the module can vary up to max. 3 A (with +5 V)
24)cycle time of the process image min. 1 s
Explanations for the column „Release“
≥5 recommended minimum release (for technical reasons). With ear- lier releases it’s possible to have some loss of functions and pro- blems with I/Os; use without guarantee
1; 2; permissible releases
=5 valid release of a module
≥6 ≥ and remark 1) mean an imperative minimum release
(6 in this case), i.e. upgrading is essential at least up to release 6.
Observe the respective indexed remarks for the individual modules.
Observe the details described in the manual „Supplementary System Documentation AS 388/TM and AS 488/TM“ (Chapter 6).■