RAID Checkout
You are now starting the RAID checkout procedure
069
(From MAP 2410 step 006 on page
–Using the DOS Configurator, open the adapter list and select the appropriate adapter.
– From the adapter menu RejectedselectDisks .
– Using the RSM configurator, go to the LogicalRejectedView .and select
ARE ANY DISK DRIVES LISTED?
Yes No
070
Go to Step 075 on page
071
– Run nonconcurrent diagnostics to all the disk drives that are listed as rejected.
–Run the Certify service aid (see “Certify Disk” on page 35) to all the rejected drives.
Go to Step 072.
072 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
(From | steps | 017 and | 071) |
|
|
|
|
|
|
| |||||||
IS ANY | DISK | DRIVE | FAILING? |
|
|
|
|
|
|
|
|
| |||||
Yes | No |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 073 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
| Go | to | Step | 075 | on | page |
|
|
|
|
| |||||
|
| Note: |
| A | disk drive that is listed as rejected is | not necessarily | failing. For | ||||||||||
|
| example, the | array might have rejected the disk | drive because a power probl | |||||||||||||
|
| or | an | SSA | link | problem, caused that drive to become | temporarily unavailable. | ||||||||||
|
| Under | such | conditions, | the | disk | drive | can | be reused. |
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
074 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| ||||||
– Exchange | the | failing | disk | drive | for | a new | one | (see | “Exchanging Disk | Drives” on | |||||||
| page | 19). |
|
|
|
|
|
|
|
|
|
|
|
| |||
(Step 074 |
| continues) |
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| MAPs |
|