Outback Power Systems GFX1448E, GFX1424E, GFX1312E manual Operation, Status LED Quick Reference

Page 14

Operation

STATUS LEDS

GREEN

¾Solid: The inverter is ON and providing power. If accompanied by solid yellow LED, unit is selling power to the utility grid. (See page 24 for a description of the Sell function.)

¾Flashing: The inverter has been turned ON but is idle. May be accompanied by the yellow LED. If not accompanied by the yellow LED, the unit is in inverting mode and is idle due to lack of demand. This can be because the unit is in Search mode. (See page 14 for a description of Search.)

¾Off: Unit is OFF. It is not waiting to provide power. Any power present is from another source such as the utility grid or generator. (See Startup on page 9, or the system display manual, to turn the unit ON.) The unit may also be a slave that is in Power Save mode. If so, the master inverter may still be providing power to the system. (See page 27 for a description of Power Save.)

YELLOW

¾Solid: The AC source is connected and providing power. Unit may or may not be charging the batteries, depending on settings. May be accompanied by green LED.

¾Flashing: The AC source is present but has not been accepted. If flashing continues, the unit is refusing the source. This can occur for the following reasons.

The AC source may have quality issues. External diagnosis may be required. (See page 15 for a description of input criteria. See the system display manual for diagnosis using the meter displays.)

In the system display, the AC Input menu is set to DROP. (See the system display manual for a description of the AC IN or AC INPUT hot key.)

In the system display, the High Battery Transfer (HBX) feature or the Grid Use feature intentionally disconnected the inverter. (See the system display manual for a description of these modes.)

¾Off: No AC source is detected. If a source is supposed to be present, confirm the voltage between AC HOT IN and AC NEUTRAL IN terminals.

RED

¾Solid: ERROR. Unit has shut down due to a critical problem which may be internal or external to the inverter. This LED is accompanied by an error message in the system display. See page 37 for a description of

error messages.

¾Flashing: WARNING. Unit has detected a non-critical problem but has not yet shut down. A warning does not always lead to a shutdown — if it does, it becomes an error. This LED is accompanied by a warning message in the system display. See page 37 for a description of warning messages.

¾Off: No problems are detected.

Table 3 Status LED Quick Reference

Color

State

Inverter State

Notes

 

Solid GREEN

Inverter is ON and providing power.

If accompanied by YELLOW LED, unit is selling.

GREEN

Flashing GREEN

Inverter is ON but standing by.

Unit may be in Search mode.

Off

Inverter is not providing power.

Unit is either OFF or has been replaced by an

 

 

 

 

AC source (see next item).

 

Solid YELLOW

AC source connected and providing

Unit may or may not be charging batteries,

 

 

power.

depending on settings.

YELLOW

Flashing YELLOW

AC source present but not yet accepted.

Unit may be programmed not to accept the

 

 

 

source, or the source may have quality issues.

 

Off

No AC source is detected.

If source is present, check AC input.

 

Solid RED

ERROR. Unit has shut down. See

To see error messages, see the system display

 

 

Troubleshooting.

manual.

RED

Flashing RED

WARNING. Unit detected a problem but

To see warning messages, see the system

 

has not yet shut down. See

display manual.

 

 

 

 

Troubleshooting.

 

 

Off

No problems detected.

 

12

900-0112-01-00 Rev B

Image 14 Contents
International Series GFX Inverter/Charger GFX1312E GFX1424E GFX1448ETrademarks Audience Symbols UsedGeneral Safety Term Definition DefinitionsTerms and Definitions Table of Contents Table of Contents List of Tables List of FiguresPage Welcome to OutBack Power Technologies IntroductionSystem Display and Controller MATE3 and Mate System Display and ControllerFunctional Test Pre-startup ProceduresCommissioning StartupPowering Down Adding New DevicesOperation LED IndicatorsBattery LED Values Operation Status LED Quick ReferenceDescription of Functions InvertingSearch InputAC Current Settings AC Source AcceptanceGenerators TransferInput Support Bulk Stage Battery ChargingNo Charging Absorption Stage SellFloat Stage Float TimerSilent Repeated SilentNew Absorption Stage Absorption TimerNew Charging Cycle Repeated Charging CyclesBattery Temperature Compensation EqualizationExamples Selling Multiple-Inverter Installations Stacking OutBack HUB4 and MateThree-Phase Stacking Parallel Stacking Dual-Stack and LargerPower Save Levels Auxiliary Terminals Operation Advanced Generator Start AGS High Battery Transfer HBXSystem Display-Based Functions Grid Use ProgrammingTroubleshooting Basic TroubleshootingTroubleshooting User To Gen in the AC Input and Current Limit Limits or Gen AC Input Voltage Limits Terminals with a DC voltmeter. If voltage is Error Messages Error TroubleshootingMessage Definition Possible Remedy Acin freq too highDisconnect Messages Acin voltage maxSelling or Charging Stopped Stop Sell and Charge Reasons Code DefinitionProgrammed setting. It cannot charge or sell Stop Sell and Charge ReasonsPage Electrical Specifications GFX1312E Value SpecificationsSpecifications for Model GFX1312E Mechanical Specifications GFX1312EMechanical Specifications GFX1424E Specifications for Model GFX1424EElectrical Specifications GFX1424E Value Mechanical Specifications GFX1448E Specifications for Model GFX1448EElectrical Specifications GFX1448E Value Environmental Specifications for All Models Value Environmental SpecificationsRegulatory Specifications Grid-Interactive UseDefault Settings and Ranges viewed in Mate 12-Volt Inverter Settings MateVolt Inverter Settings Mate Input48-Volt Inverter Settings Mate Battery vdc adjustment26Default Settings and Ranges viewed in MATE3 Volt Inverter Settings MATE324-Volt Inverter Settings MATE3 Vent Fan Enable VoltageStacking Power Save OutBack Power Technologies Product RegistrationProduct Registration Warranty Year Limited Warranty for GFX ProductsReturn Material Authorization RMA How to Arrange for Warranty ServiceTroubleshooting Contacting OutBackOut of Warranty Returning Product to OutBackThis page intentionally left blank Index AUX FunctionsIndex Index Arlington, WA 98223 USA +1.360.435.6030