Outback Power Systems GFX1312E, GFX1424E, GFX1448E manual Default Settings and Ranges viewed in Mate

Page 49

Specifications

Default Settings and Ranges (viewed in MATE)

Table 17 12-Volt Inverter Settings (MATE)

Field

Item

Default

Minimum

Maximum

 

search sensitivity (see page 14 for increments)

6

0

 

50

Search

search pulse length

8

4

 

20

 

search pulse spacing

60 AC cycles

4 AC cycles

 

120 AC cycles

 

ac transfer control

Grid

 

Grid or Gen

Input

ac1/grid limit

25 Aac

2.5 Aac

 

30 Aac

 

ac2/gen limit

25 Aac

2.5 Aac

 

30 Aac

 

low battery cut-out (LBCO)

10.5 Vdc

9 Vdc

 

12 Vdc

Inverter

low battery cut-in (LBCI)

12.5 Vdc

10 Vdc

 

14 Vdc

 

adjust output voltage

230 Vac

210 Vac

 

250 Vac

 

charger limit

5 Aac

0 Aac

 

6 Aac

 

absorb voltage

14.4 Vdc

13 Vdc

 

16 Vdc

 

absorb time limit

1.0 hours

0.0 hours

 

24.0 hours

Charger

float voltage

13.6 Vdc

12 Vdc

 

15 Vdc

float time period

1.0 hours

0.0 hours

 

24.0 hours

 

 

 

refloat voltage

12.5 Vdc

12 Vdc

 

13 Vdc

 

equalization voltage

14.6 Vdc

14 Vdc

 

17 Vdc

 

equalization time period

1.0 hours

0.0 hours

 

24.0 hours

 

ac1/grid lower limit

208 Vac

140 Vac

 

220 Vac

Grid

ac1/grid upper limit

252 Vac

250 Vac

 

280 Vac

ac1/grid input limit

25 Aac

2.5 Aac

 

30 Aac

 

 

 

ac1/grid transfer delay

6 AC cycles

0 AC cycles

 

240 AC cycles

 

gen input connect delay

0.5 minutes

0.2 minutes

 

15 minutes

Generator

ac2/gen lower limit

208 Vac

140 Vac

 

220 Vac

ac2/gen upper limit

252 Vac

250 Vac

 

280 Vac

(Gen)

ac2/gen input limit

25 Aac

2.5 Aac

 

30 Aac

 

ac2/gen transfer delay

6 AC cycles

0 AC cycles

 

240 AC cycles

 

ac2/gen support

ON

 

ON or OFF

 

aux output control

AUTO

ON, OFF, or AUTO

 

aux output function

Cool Fan

Cool Fan, DivertDC, DivertAC, AC Drop, Vent

 

 

Fan, Fault, GenAlert, LoadShed, or Remote

 

 

 

 

genalert on voltage

11 Vdc

10 Vdc

 

14 Vdc

Auxiliary

genalert on delay

4 minutes

0 minutes

 

240 minutes

genalert off set point

14 Vdc

12 Vdc

 

18 Vdc

(AUX)

genalert off delay

9 minutes

0 minutes

 

240 minutes

 

load shed off voltage

11 Vdc

10 Vdc

 

14 Vdc

 

vent fan on set point

13 Vdc

10 Vdc

 

16 Vdc

 

vent fan off period

5 minutes

0 minutes

 

30 minutes

 

diversion on voltage

14.6 Vdc

12 Vdc

 

16 Vdc

 

diversion off delay

30 seconds

0 seconds

 

240 seconds

Stacking

stack phase

Master

Master, OB Slave L1, 3p Classic B, 3p Classic C

Power Save

master adjust only

0

0

 

7

slave adjust only

1

1

 

15

 

 

Sell

sell re volts

13 Vdc

10 Vdc

 

15 Vdc

grid tie window

User

 

IEEE or User

 

grid tie authority

GridTie

GridTie or No Sell

Calibration

vac input adjustment1

236

220

 

254

vac output adjustment1

236

220

 

254

(Cal)

 

battery vdc adjustment2

2

0

 

4

 

 

1These values are in digital counts, not volts. Lower counts stand for higher voltages, and higher counts mean lower voltages. One count equals approximately 1 Vac. The range of adjustment is 15 Vac above nominal and 17 Vac below nominal.

2These values are in digital counts, not volts. One count equals 0.1 Vdc. The range of adjustment is 0.2 Vdc above or below nominal.

900-0112-01-00 Rev B

47

Image 49
Contents GFX1312E GFX1424E GFX1448E International Series GFX Inverter/ChargerTrademarks General Safety Symbols UsedAudience Terms and Definitions DefinitionsTerm Definition Table of Contents Table of Contents List of Figures List of TablesPage Introduction Welcome to OutBack Power TechnologiesMATE3 and Mate System Display and Controller System Display and ControllerCommissioning Pre-startup ProceduresFunctional Test StartupAdding New Devices Powering DownBattery LED Values LED IndicatorsOperation Status LED Quick Reference OperationInverting Description of FunctionsInput SearchAC Source Acceptance AC Current SettingsTransfer GeneratorsInput Support No Charging Battery ChargingBulk Stage Sell Absorption StageSilent Float TimerFloat Stage Repeated SilentNew Charging Cycle Absorption TimerNew Absorption Stage Repeated Charging CyclesEqualization Battery Temperature CompensationExamples Selling OutBack HUB4 and Mate Multiple-Inverter Installations StackingParallel Stacking Dual-Stack and Larger Three-Phase StackingPower Save Levels Auxiliary Terminals Operation System Display-Based Functions High Battery Transfer HBXAdvanced Generator Start AGS Grid Use ProgrammingBasic Troubleshooting TroubleshootingTroubleshooting User To Gen in the AC Input and Current Limit Limits or Gen AC Input Voltage Limits Terminals with a DC voltmeter. If voltage is Error Troubleshooting Error MessagesAcin freq too high Message Definition Possible RemedyAcin voltage max Disconnect MessagesStop Sell and Charge Reasons Code Definition Selling or Charging StoppedStop Sell and Charge Reasons Programmed setting. It cannot charge or sellPage Specifications for Model GFX1312E SpecificationsElectrical Specifications GFX1312E Value Mechanical Specifications GFX1312EElectrical Specifications GFX1424E Value Specifications for Model GFX1424EMechanical Specifications GFX1424E Electrical Specifications GFX1448E Value Specifications for Model GFX1448EMechanical Specifications GFX1448E Regulatory Specifications Environmental SpecificationsEnvironmental Specifications for All Models Value Grid-Interactive Use12-Volt Inverter Settings Mate Default Settings and Ranges viewed in MateInput Volt Inverter Settings MateBattery vdc adjustment26 48-Volt Inverter Settings MateVolt Inverter Settings MATE3 Default Settings and Ranges viewed in MATE3Vent Fan Enable Voltage 24-Volt Inverter Settings MATE3Stacking Power Save Product Registration OutBack Power TechnologiesProduct Registration Year Limited Warranty for GFX Products WarrantyTroubleshooting How to Arrange for Warranty ServiceReturn Material Authorization RMA Contacting OutBackReturning Product to OutBack Out of WarrantyThis page intentionally left blank AUX Functions IndexIndex Index Arlington, WA 98223 USA +1.360.435.6030
Related manuals
Manual 40 pages 41.66 Kb

GFX1448E, GFX1424E, GFX1312E specifications

Outback Power Systems has long been recognized for its innovation and reliability in the field of renewable energy solutions, particularly with its GFX series of grid-tied inverters. The GFX1312E, GFX1424E, and GFX1448E models exemplify their commitment to quality and performance, making them ideal choices for both residential and commercial applications.

The GFX1312E is designed to deliver a solid 1300 watts of continuous output power at 12 volts, offering efficient energy conversion for smaller solar setups or off-grid living situations. Its compact design allows for easy installation, while advanced engineering ensures high performance even in challenging conditions. The GFX1312E features a pure sine wave output, which is critical for sensitive electronic devices, ensuring compatibility and safeguarding against potential damage.

Moving up in power capacity, the GFX1424E operates at 1400 watts with a 24-volt configuration. This model is particularly well-suited for medium-sized solar energy systems. It supports 120/240 volts split-phase output, providing greater flexibility for various household appliances and ensuring that users can maximize their energy usage with efficiency. The GFX1424E also incorporates an extensive array of intelligent charging profiles that optimize battery performance and longevity.

The GFX1448E caps the series with impressive 1400 watts of continuous output at 48 volts, catering primarily to larger installations and those requiring more robust energy management solutions. This inverter is equipped with Outback's patented GridZero™ technology, allowing for seamless integration of solar energy production with utility power, helping users to minimize grid dependence while maximizing savings. With advanced features like backup capability and grid-interactive operation, this model is highly versatile.

All three models share key characteristics such as network connectivity through the Outback Power's MATE series of controllers, enabling real-time monitoring and system management. They are designed for durability and have protective features against overloads and short circuits, ensuring reliable performance over time. With their modular design, users can easily scale their system by connecting multiple units, making these inverters a practical choice for expanding energy needs.

In summary, the Outback Power Systems GFX1312E, GFX1424E, and GFX1448E inverters provide top-tier options for those looking to harness solar energy efficiently. Their respective power outputs, advanced technologies, and user-friendly interfaces position them as excellent choices for both residential and commercial energy solutions, underscoring Outback's reputation as a leader in the renewable energy market.