Outback Power Systems GFX1312E, GFX1424E, GFX1448E Default Settings and Ranges viewed in MATE3

Page 52

Specifications

Default Settings and Ranges (viewed in MATE3)

 

Table 20

12-Volt Inverter Settings (MATE3)

 

 

Field

Item

 

Default

Minimum

 

Maximum

 

Sensitivity (see page 14 for increments)

6

0

 

50

Search

Pulse Length

 

8

4

 

20

 

Pulse Spacing

 

60 AC cycles

4 AC cycles

 

120 AC cycles

 

Input Type

 

Grid

 

Grid or Gen

AC Input and

Input Support

 

Y

 

Y or N

Grid Input AC Limit

 

25 Aac

2.5 Aac

 

30 Aac

Current Limit

 

 

Gen Input AC Limit

 

25 Aac

2.5 Aac

 

30 Aac

 

 

 

 

Charger AC Limit

 

5 Aac

0 Aac

 

6 Aac

Grid AC Input

LowerVoltage Limit

 

208 Vac

140 Vac

 

220 Vac

Upper Voltage Limit

 

252 Vac

250 Vac

 

280 Vac

Voltage Limits

 

 

Transfer Delay

 

6 AC cycles

0 AC cycles

 

240 AC cycles

 

 

 

 

 

 

 

 

 

 

 

LowerVoltage Limit

 

208 Vac

140 Vac

 

220 Vac

Gen AC Input

Upper Voltage Limit

 

252 Vac

250 Vac

 

280 Vac

Voltage Limits

Transfer Delay

 

6 AC cycles

0 AC cycles

 

240 AC cycles

 

Connect Delay

 

0.5 minutes

0.2 minutes

 

15 minutes

AC Output

AC Output

 

230 Vac

210 Vac

 

250 Vac

Low Battery

Cut-Out Voltage

 

10.5 Vdc

9 Vdc

 

12 Vdc

Cut-In Voltage

 

12.5 Vdc

10 Vdc

 

14 Vdc

 

 

 

 

Absorb Voltage

 

14.4 Vdc

13 Vdc

 

16 Vdc

 

(Absorb) Time

 

1.0 hours

0.0 hours

 

24.0 hours

Battery Charger

Float Voltage

 

13.6 Vdc

12 Vdc

 

15 Vdc

 

(Float) Time

 

1.0 hours

0.0 hours

 

24.0 hours

 

Re-Float Voltage

 

12.5 Vdc

12 Vdc

 

13 Vdc

Battery Equalize

Equalize Voltage

 

14.6 Vdc

14 Vdc

 

17 Vdc

(Equalize) Time

 

1.0 hours

0.0 hours

 

24.0 hours

 

 

 

 

Aux Mode

 

Cool Fan

Remote, Load Shed, Gen Alert, Fault, Vent Fan,

 

 

Cool Fan, Divert DC, Divert AC, or AC Drop

 

 

 

 

 

(Load Shed) Enable Voltage

 

11 Vdc

10 Vdc

 

14 Vdc

 

(Gen Alert) ON Voltage

 

11 Vdc

10 Vdc

 

14 Vdc

Auxiliary

(Gen Alert ON) Delay

 

4 minutes

0 minutes

 

240 minutes

(Gen Alert) OFF Voltage

 

14 Vdc

12 Vdc

 

18 Vdc

Output

 

 

(Gen Alert OFF) Delay

 

9 minutes

0 minutes

 

240 minutes

 

 

 

 

(Vent Fan) Enable Voltage

 

13 Vdc

10 Vdc

 

16 Vdc

 

(Vent Fan) Off Period

 

5 minutes

0 minutes

 

30 minutes

 

(Divert DC or AC) Enable Voltage

14.6 Vdc

12 Vdc

 

16 Vdc

 

(Divert DC or AC) Off Delay

 

30 seconds

0 seconds

 

240 seconds

Inverter Stacking

Stack Mode

 

Master

Master, OB Slave L1, 3p Classic B , 3p Classic C

 

 

 

 

 

 

Power Save

Master Adjust Only

 

0

0

 

7

Slave Adjust Only

 

1

1

 

15

 

 

 

 

Grid Tie Enable

 

Y

 

Y or N

Grid-Tie Sell

Sell Voltage

 

13 Vdc

10 Vdc

 

15 Vdc

 

Grid Tie Window

 

IEEE

 

IEEE or user

 

Input Voltage7

 

-1

-3

 

1

Calibrate

Output Voltage7

 

-1

-3

 

1

 

Battery Voltage8

 

0.0

-0.2

 

0.2

7These values represent an adjustable setting with a total range of 4 Vac. The default value of -1 means the calibration will subtract 1 volt from the measured value. The range of settings allow up to 1 volt to be added to the measured value, or up to 3 volts to be subtracted from it. The result is also displayed.

8These values represent an adjustable setting with a range of ± 0.2 Vdc from the measured value. The range of settings allow up to 0.2 volts to be either added or subtracted from the measured value. The result is also displayed.

50

900-0112-01-00 Rev B

Image 52
Contents International Series GFX Inverter/Charger GFX1312E GFX1424E GFX1448ETrademarks General Safety Symbols UsedAudience Terms and Definitions DefinitionsTerm Definition Table of Contents Table of Contents List of Tables List of FiguresPage Welcome to OutBack Power Technologies IntroductionSystem Display and Controller MATE3 and Mate System Display and ControllerPre-startup Procedures CommissioningFunctional Test StartupPowering Down Adding New DevicesBattery LED Values LED IndicatorsOperation Operation Status LED Quick ReferenceDescription of Functions InvertingSearch InputAC Current Settings AC Source AcceptanceGenerators TransferInput Support No Charging Battery ChargingBulk Stage Absorption Stage SellFloat Timer SilentFloat Stage Repeated SilentAbsorption Timer New Charging CycleNew Absorption Stage Repeated Charging CyclesBattery Temperature Compensation EqualizationExamples Selling Multiple-Inverter Installations Stacking OutBack HUB4 and MateThree-Phase Stacking Parallel Stacking Dual-Stack and LargerPower Save Levels Auxiliary Terminals Operation High Battery Transfer HBX System Display-Based FunctionsAdvanced Generator Start AGS Grid Use ProgrammingTroubleshooting Basic TroubleshootingTroubleshooting User To Gen in the AC Input and Current Limit Limits or Gen AC Input Voltage Limits Terminals with a DC voltmeter. If voltage is Error Messages Error TroubleshootingMessage Definition Possible Remedy Acin freq too highDisconnect Messages Acin voltage maxSelling or Charging Stopped Stop Sell and Charge Reasons Code DefinitionProgrammed setting. It cannot charge or sell Stop Sell and Charge ReasonsPage Specifications Specifications for Model GFX1312EElectrical Specifications GFX1312E Value Mechanical Specifications GFX1312EElectrical Specifications GFX1424E Value Specifications for Model GFX1424EMechanical Specifications GFX1424E Electrical Specifications GFX1448E Value Specifications for Model GFX1448EMechanical Specifications GFX1448E Environmental Specifications Regulatory SpecificationsEnvironmental Specifications for All Models Value Grid-Interactive UseDefault Settings and Ranges viewed in Mate 12-Volt Inverter Settings MateVolt Inverter Settings Mate Input48-Volt Inverter Settings Mate Battery vdc adjustment26Default Settings and Ranges viewed in MATE3 Volt Inverter Settings MATE324-Volt Inverter Settings MATE3 Vent Fan Enable VoltageStacking Power Save OutBack Power Technologies Product RegistrationProduct Registration Warranty Year Limited Warranty for GFX ProductsHow to Arrange for Warranty Service TroubleshootingReturn Material Authorization RMA Contacting OutBackOut of Warranty Returning Product to OutBackThis page intentionally left blank Index AUX FunctionsIndex Index Arlington, WA 98223 USA +1.360.435.6030
Related manuals
Manual 40 pages 41.66 Kb

GFX1448E, GFX1424E, GFX1312E specifications

Outback Power Systems has long been recognized for its innovation and reliability in the field of renewable energy solutions, particularly with its GFX series of grid-tied inverters. The GFX1312E, GFX1424E, and GFX1448E models exemplify their commitment to quality and performance, making them ideal choices for both residential and commercial applications.

The GFX1312E is designed to deliver a solid 1300 watts of continuous output power at 12 volts, offering efficient energy conversion for smaller solar setups or off-grid living situations. Its compact design allows for easy installation, while advanced engineering ensures high performance even in challenging conditions. The GFX1312E features a pure sine wave output, which is critical for sensitive electronic devices, ensuring compatibility and safeguarding against potential damage.

Moving up in power capacity, the GFX1424E operates at 1400 watts with a 24-volt configuration. This model is particularly well-suited for medium-sized solar energy systems. It supports 120/240 volts split-phase output, providing greater flexibility for various household appliances and ensuring that users can maximize their energy usage with efficiency. The GFX1424E also incorporates an extensive array of intelligent charging profiles that optimize battery performance and longevity.

The GFX1448E caps the series with impressive 1400 watts of continuous output at 48 volts, catering primarily to larger installations and those requiring more robust energy management solutions. This inverter is equipped with Outback's patented GridZero™ technology, allowing for seamless integration of solar energy production with utility power, helping users to minimize grid dependence while maximizing savings. With advanced features like backup capability and grid-interactive operation, this model is highly versatile.

All three models share key characteristics such as network connectivity through the Outback Power's MATE series of controllers, enabling real-time monitoring and system management. They are designed for durability and have protective features against overloads and short circuits, ensuring reliable performance over time. With their modular design, users can easily scale their system by connecting multiple units, making these inverters a practical choice for expanding energy needs.

In summary, the Outback Power Systems GFX1312E, GFX1424E, and GFX1448E inverters provide top-tier options for those looking to harness solar energy efficiently. Their respective power outputs, advanced technologies, and user-friendly interfaces position them as excellent choices for both residential and commercial energy solutions, underscoring Outback's reputation as a leader in the renewable energy market.