Outback Power Systems GFX1448E, GFX1424E, GFX1312E manual Disconnect Messages, Acin voltage max

Page 41

Troubleshooting

Disconnect Messages

Disconnect screens explain the reason that the inverter rejected an AC source. The unit returns to inverting mode (if turned on). The ERROR LED (see page 11) will not illuminate for a disconnect message, although it may flash for a concurrent warning following the disconnect. (See previous section.) If the AC source is removed, the warning and the LED will be blank, but the cause of the last disconnect will remain. See the system display manual for instructions on viewing disconnect messages. One or more messages in this menu will display yes in the MATE system display; Y in the MATE3. If a message says no (or N), it is not the cause of the disconnection.

Disconnect screens only display the reason for the disconnection; they cannot correct it. It is usually the result of external conditions, not an inverter fault. A few settings can be changed to accommodate problems with the AC source.

Disconnect messages are not the same as the Stop Sell Reasons (see next page), although they may be caused by the same circumstances. A grid-interactive unit can stop selling and still remain connected to the utility grid.

Table 7 Disconnect Troubleshooting

Message

Definition

Possible Remedy

 

 

 

acin freq too high

The unit disconnects if the AC source

Check AC source. If it is a generator,

 

exceeds 55 Hz.

reduce speed.

 

 

 

acin freq too low

The unit disconnects if the AC source

Check AC source. If it is a generator,

 

drops below 45 Hz.

increase speed.

 

 

 

acin voltage > max

The unit disconnects if the AC source

Check AC source. The inverter’s

 

exceeds 252 Vac (default value).

acceptance range is adjustable. However,

 

 

this will accommodate an AC problem, not

 

 

fix it.

 

 

 

acin voltage < min

The unit disconnects if the AC source

Check AC source. The inverter’s

 

drops below 208 Vac (default value).

acceptance range is adjustable. However,

 

 

this will accommodate an AC problem, not

 

 

fix it.

 

 

 

900-0112-01-00 Rev B

39

Image 41
Contents GFX1312E GFX1424E GFX1448E International Series GFX Inverter/ChargerTrademarks Audience Symbols UsedGeneral Safety Term Definition DefinitionsTerms and Definitions Table of Contents Table of Contents List of Figures List of TablesPage Introduction Welcome to OutBack Power TechnologiesMATE3 and Mate System Display and Controller System Display and ControllerCommissioning Pre-startup ProceduresFunctional Test StartupAdding New Devices Powering DownOperation LED IndicatorsBattery LED Values Status LED Quick Reference OperationInverting Description of FunctionsInput SearchAC Source Acceptance AC Current SettingsTransfer GeneratorsInput Support Bulk Stage Battery ChargingNo Charging Sell Absorption StageSilent Float TimerFloat Stage Repeated SilentNew Charging Cycle Absorption TimerNew Absorption Stage Repeated Charging CyclesEqualization Battery Temperature CompensationExamples Selling OutBack HUB4 and Mate Multiple-Inverter Installations StackingParallel Stacking Dual-Stack and Larger Three-Phase StackingPower Save Levels Auxiliary Terminals Operation System Display-Based Functions High Battery Transfer HBXAdvanced Generator Start AGS Grid Use ProgrammingBasic Troubleshooting TroubleshootingTroubleshooting User To Gen in the AC Input and Current Limit Limits or Gen AC Input Voltage Limits Terminals with a DC voltmeter. If voltage is Error Troubleshooting Error MessagesAcin freq too high Message Definition Possible RemedyAcin voltage max Disconnect MessagesStop Sell and Charge Reasons Code Definition Selling or Charging StoppedStop Sell and Charge Reasons Programmed setting. It cannot charge or sellPage Specifications for Model GFX1312E SpecificationsElectrical Specifications GFX1312E Value Mechanical Specifications GFX1312EMechanical Specifications GFX1424E Specifications for Model GFX1424EElectrical Specifications GFX1424E Value Mechanical Specifications GFX1448E Specifications for Model GFX1448EElectrical Specifications GFX1448E Value Regulatory Specifications Environmental SpecificationsEnvironmental Specifications for All Models Value Grid-Interactive Use12-Volt Inverter Settings Mate Default Settings and Ranges viewed in MateInput Volt Inverter Settings MateBattery vdc adjustment26 48-Volt Inverter Settings MateVolt Inverter Settings MATE3 Default Settings and Ranges viewed in MATE3Vent Fan Enable Voltage 24-Volt Inverter Settings MATE3Stacking Power Save Product Registration OutBack Power TechnologiesProduct Registration Year Limited Warranty for GFX Products WarrantyTroubleshooting How to Arrange for Warranty ServiceReturn Material Authorization RMA Contacting OutBackReturning Product to OutBack Out of WarrantyThis page intentionally left blank AUX Functions IndexIndex Index Arlington, WA 98223 USA +1.360.435.6030
Related manuals
Manual 40 pages 41.66 Kb

GFX1448E, GFX1424E, GFX1312E specifications

Outback Power Systems has long been recognized for its innovation and reliability in the field of renewable energy solutions, particularly with its GFX series of grid-tied inverters. The GFX1312E, GFX1424E, and GFX1448E models exemplify their commitment to quality and performance, making them ideal choices for both residential and commercial applications.

The GFX1312E is designed to deliver a solid 1300 watts of continuous output power at 12 volts, offering efficient energy conversion for smaller solar setups or off-grid living situations. Its compact design allows for easy installation, while advanced engineering ensures high performance even in challenging conditions. The GFX1312E features a pure sine wave output, which is critical for sensitive electronic devices, ensuring compatibility and safeguarding against potential damage.

Moving up in power capacity, the GFX1424E operates at 1400 watts with a 24-volt configuration. This model is particularly well-suited for medium-sized solar energy systems. It supports 120/240 volts split-phase output, providing greater flexibility for various household appliances and ensuring that users can maximize their energy usage with efficiency. The GFX1424E also incorporates an extensive array of intelligent charging profiles that optimize battery performance and longevity.

The GFX1448E caps the series with impressive 1400 watts of continuous output at 48 volts, catering primarily to larger installations and those requiring more robust energy management solutions. This inverter is equipped with Outback's patented GridZero™ technology, allowing for seamless integration of solar energy production with utility power, helping users to minimize grid dependence while maximizing savings. With advanced features like backup capability and grid-interactive operation, this model is highly versatile.

All three models share key characteristics such as network connectivity through the Outback Power's MATE series of controllers, enabling real-time monitoring and system management. They are designed for durability and have protective features against overloads and short circuits, ensuring reliable performance over time. With their modular design, users can easily scale their system by connecting multiple units, making these inverters a practical choice for expanding energy needs.

In summary, the Outback Power Systems GFX1312E, GFX1424E, and GFX1448E inverters provide top-tier options for those looking to harness solar energy efficiently. Their respective power outputs, advanced technologies, and user-friendly interfaces position them as excellent choices for both residential and commercial energy solutions, underscoring Outback's reputation as a leader in the renewable energy market.