Outback Power Systems GFX1312E, GFX1448E manual Specifications for Model GFX1424E

Page 46

Specifications

Specifications for Model GFX1424E

Table 11 Electrical Specifications (GFX1424E)

Specification

Value

Nominal DC Input Voltage

24 Vdc

Continuous Output Power at 25°C

1400 VA

AC Output Voltage

230 Vac

AC Output Frequency

50 Hz

Continuous AC Output Current at 25°C

6.09 Aac

Waveform

True Sinewave

Efficiency (typical)

92%

Total Harmonic Distortion (typical)

2%

Output Voltage Regulation

± 2%

Maximum Output Current (1 ms peak)

28 Aac

Maximum Output Current (100 ms RMS)

20 Aac

Overload Capability (100 ms surge)

4600 VA

Overload Capability (5 second)

2900 VA

Overload Capability (30 minute)

2000 VA

Idle Consumption - Invert mode, no load

18 Watts

Idle Consumption - Search Mode

6 Watts

AC Input Voltage Range (Adjustable)

140 to 280 Vac

AC Input Frequency Range

45 to 55 Hz

AC Input Current (Maximum)

30 Aac

Grid-Interactive Voltage Range (Default)

208 to 252 Vac

Grid-Interactive Frequency Range (Default)

48 to 52 Hz

Battery Charger Maximum AC Input

6 Aac

Battery Charger Max Continuous DC Output

40 Adc

DC Input Voltage Range

21.0 to 34.0 Vdc

DC Input Current at Rated Power

70 Adc

Maximum DC Input Current on Surge

230 Adc

Auxiliary Output

12 Vdc, 0.7 Adc

Table 12 Mechanical Specifications (GFX1424E)

 

 

 

Specification

 

Value

Inverter Dimensions (H x W x L)

 

33 cm (13”) x 21 cm (8.25”) x 41 cm (16.25”)

Shipping Dimensions (H x W x L)

 

55 cm (21.75”) x 33 cm (13”) x 56 cm (22”)

Inverter Weight

 

22.5 kg (49.6 lb)

Shipping Weight

 

25.6 kg (56.4 lb)

Accessory Ports

 

RJ11 and RJ45

Non-volatile Memory

 

Yes

Neutral-Ground Bond Switching

 

No

Turbo Fan

 

No

Chassis Type

 

Sealed

44

900-0112-01-00 Rev B

Image 46 Contents
International Series GFX Inverter/Charger GFX1312E GFX1424E GFX1448ETrademarks General Safety Symbols UsedAudience Terms and Definitions DefinitionsTerm Definition Table of Contents Table of Contents List of Tables List of FiguresPage Welcome to OutBack Power Technologies IntroductionSystem Display and Controller MATE3 and Mate System Display and ControllerFunctional Test Pre-startup ProceduresCommissioning StartupPowering Down Adding New DevicesBattery LED Values LED IndicatorsOperation Operation Status LED Quick ReferenceDescription of Functions InvertingSearch InputAC Current Settings AC Source AcceptanceGenerators TransferInput Support No Charging Battery ChargingBulk Stage Absorption Stage SellFloat Stage Float TimerSilent Repeated SilentNew Absorption Stage Absorption TimerNew Charging Cycle Repeated Charging CyclesBattery Temperature Compensation EqualizationExamples Selling Multiple-Inverter Installations Stacking OutBack HUB4 and MateThree-Phase Stacking Parallel Stacking Dual-Stack and LargerPower Save Levels Auxiliary Terminals Operation Advanced Generator Start AGS High Battery Transfer HBXSystem Display-Based Functions Grid Use ProgrammingTroubleshooting Basic TroubleshootingTroubleshooting User To Gen in the AC Input and Current Limit Limits or Gen AC Input Voltage Limits Terminals with a DC voltmeter. If voltage is Error Messages Error TroubleshootingMessage Definition Possible Remedy Acin freq too highDisconnect Messages Acin voltage maxSelling or Charging Stopped Stop Sell and Charge Reasons Code DefinitionProgrammed setting. It cannot charge or sell Stop Sell and Charge ReasonsPage Electrical Specifications GFX1312E Value SpecificationsSpecifications for Model GFX1312E Mechanical Specifications GFX1312EElectrical Specifications GFX1424E Value Specifications for Model GFX1424EMechanical Specifications GFX1424E Electrical Specifications GFX1448E Value Specifications for Model GFX1448EMechanical Specifications GFX1448E Environmental Specifications for All Models Value Environmental SpecificationsRegulatory Specifications Grid-Interactive UseDefault Settings and Ranges viewed in Mate 12-Volt Inverter Settings MateVolt Inverter Settings Mate Input48-Volt Inverter Settings Mate Battery vdc adjustment26Default Settings and Ranges viewed in MATE3 Volt Inverter Settings MATE324-Volt Inverter Settings MATE3 Vent Fan Enable VoltageStacking Power Save OutBack Power Technologies Product RegistrationProduct Registration Warranty Year Limited Warranty for GFX ProductsReturn Material Authorization RMA How to Arrange for Warranty ServiceTroubleshooting Contacting OutBackOut of Warranty Returning Product to OutBackThis page intentionally left blank Index AUX FunctionsIndex Index Arlington, WA 98223 USA +1.360.435.6030