System Configuration and Part Numbers

Hazardous Location Approval

Models using a G3000, G3000HR, or intrinsically safe Coriolis meter for both A and B meters are approved for installation in a Hazardous Location - Class I, Div I, Group D, T3 or Zone I Group IIA T3.

Maximum Working Pressure

Maximum working pressure rating is dependent on the fluid component options selected. The pressure rating is based on the rating of the lowest rated fluid component. Refer to the component pressure ratings below. Example: Model 262383 has a maximum working pressure of 190 psi (1.31 MPa, 13.1 bar).

Check the identification label on the EasyKey or fluid station for the system maximum working pressure. See FIG. 1.

ProControl Fluid Components Maximum Working Pressure

Base System (no meter, no color/catalyst change option,

and no flow control [option). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4000 psi (27.58 MPa, 275.8 bar) G3000 Meter Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4000 psi (27.58 MPa, 275.8 bar) Coriolis Meter Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2300 psi (15.86 MPa, 158.6 bar) Color Change Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300 psi (2.07 MPa, 20.6 bar) Flow Control Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .190 psi (1.31 MPa 13.1 bar)

Flow Meter Fluid Flow Rate Range

G3000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75-3800 cc/min. (0.02-1.0 gal./min.) G3000HR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38-1900 cc/min. (0.01-0.50 gal./min.) Coriolis Meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-3800 cc/min. (0.005-1.00 gal./min.) S3000 Solvent Meter (accessory) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38-1900 cc/min. (0.01-0.50 gal./min.)

Standard Features

Feature

EasyKey with LCD

RS 485 Network Cable, 50 ft (15.25 m)

Fiber Optic and Power Cables, 50 ft (15.25 m)

Fluid Station Control Box

Discrete I/O Board

A Side Dump Valve, if color valve(s) selected

Flow Control with 15 ft (4.57 m) Cable (if selected)

Basic Web Interface

Accessories

Accessory

15V536 Solvent Flow Switch Kit

15V213 Power Cable, 100 ft (30.5 m)

15G710 Fiber Optic Cable, 100 ft (30.5 m)

15G614 Flow Control Extension Cable, 40 ft (12.2 m)

15W034 Strobe Light Alarm Indicator Kit

15V331 Gateway Ethernet Communication Kit

15V963 Gateway DeviceNet Communication Kit

15V964 Gateway Profibus Communication Kit

15V337 Advanced Web Interface

3A1163A

5

Image 5
Contents II 2 G ProControl 1KS Contents Equipment Approvals Related ManualsLabel Location on EasyKey System Configuration and Part NumbersModels Accessory FeatureFire and Explosion Hazard Skin Injection Hazard Toxic Fluid or Fumes Hazard Important Two-Component Material Information Component Identification and Definition Assembly FC Control Box Power Supply Cable PS Flow ControlComponent Description Fluid Manifold FM Pneumatically Operated Dose Valve for component aLocation Intrinsically Safe Installation RequirementsLocation Requirements Optional CablesRequirements on NON-HAZARDOUS Hazardous Classified Location Location onlyWall Mounting See Dimensions and Mounting Hole Layouts,General Information ProControl 1KS System Layout Drawing Wall Mounting Air Supply See the System Pneumatic Schematic onRequirements Air ConnectionsFluid Connections Fluid SupplyColor Change Valve Stack TI11668a Color Change Board and Solenoid ValvesFlow Control Regulator Regulator Fluid Air Fluid Out FC CableElectrical Requirements Connect Main PowerConnect EasyKey to Fluid Station Control EasyKey Connections and AC Power SwitchFluid Station Board Connections One Color Change Board Color Change Board Switch Settings Two Color Change BoardsConnect Color Change Module Positions Switch S3-S6J11 IG . Color Change Board Switches S3-S6 Wiring Diagram Check Resistance GroundingRobot EasyKey Display Control BoxSystem Pneumatic Schematic Schematic DiagramsNon-Hazardous Area System Electrical SchematicHazardous Area Wall Panel Mounting bracket only Dimensions and Mounting Hole LayoutsFlow Control Module Air Supply Control EasyKeyDimensions and Mounting Hole Layouts Maximum fluid working pressure Maximum working air pressure Technical DataGraco Information Graco Standard Warranty