Electrical
|
| AC Power |
Fiber Optic Strain | Audible Alarm | Switch |
Relief Port |
|
|
Main Power
Access Port
Ground Screw | I/S Power | Graco Web | Discrete I/O Cable |
|
|
| Interface | Connector Ports |
|
|
|
| TI12638a | TI12657a |
FIG. 10. EasyKey Connections and AC Power Switch
Connect EasyKey to Fluid Station Control
There are two 50 ft (15.2 m) cables to route between the EasyKey and Fluid Station Control: the Fluid Station Power Cable and the Fiber Optic Cable.
1.Connect the appropriate Fluid Station Power Cable end to the EasyKey connector VDC . See FIG. 10.
2.Connect the other cable end to the Fluid Station
Control connector VDC (J10). See FIG. 11.
3.The Fiber Optic Cable is shipped from the factory
attached to the EasyKey connector . See FIG. 10.
NOTE: If you need to detach the Fiber Optic Cable from the EasyKey, note how the cable is routed inside the enclosure. Ensure that the door can swing open and close without catching or pulling wires.
4.Route the opposite Fiber Optic Cable end through
the Fluid Station strain relief connector . Do not route the cable with tight bends or kinks.
NOTE: The fiber optic cable has a minimum bend radius of 1.6 in. (40 mm).
5.Connect the blue and black cable connectors to the matching connectors on the fluid station circuit board. See FIG. 11. Insert the cable connectors until they bottom out (approximately ¼ in. [6 mm]), then tighten the threaded connector.
NOTICE
To avoid cracking the circuit board, do not
6. Tighten the strain relief connector .
22 | 3A1163A |