Electrical

Electrical

Requirements

Connect Main Power

All electrical wiring must be completed by a qualified electrician and comply with all local codes and regula- tions.

Enclose all cables routed in the spray booth and high traffic areas in conduit to prevent damage from paint, solvent, and traffic.

NOTE: All options ordered on the ProControl system are electrically tested at the factory.

The ProControl operates with 85-250 VAC, 50/60 Hz input power, with a maximum of 2 amp current draw. The power supply circuit must be protected with a 15 amp maximum circuit breaker.

Not included with system:

Power supply cord compatible to your local power configuration. Wire gauge size must be 8-14 AWG.

The input power access port is 22.4 mm (0.88 in.) diameter. It accepts a bulkhead strain relief fitting or conduit. See FIG. 10.

1.Provide power to the EasyKey. Install a bulkhead strain relief or conduit bulkhead through the

EasyKey port . See FIG. 10.

2.See FIG. 9 and the System Electrical Schematic on page 30 for the L1, N, and ground wiring connec- tions inside the EasyKey.

3.Ground the EasyKey to a true earth ground. See Grounding, page 27.

Input Power

 

Terminal Block

TI13349a

FIG. 9. Main Power Connection

3A1163A

21

Image 21
Contents II 2 G ProControl 1KSContents Equipment Approvals Related ManualsSystem Configuration and Part Numbers ModelsLabel Location on EasyKey Accessory FeatureFire and Explosion Hazard Skin Injection Hazard Toxic Fluid or Fumes Hazard Important Two-Component Material Information Component Identification and Definition Assembly FC Control Box Power Supply Cable PS Flow ControlComponent Description Fluid Manifold FM Pneumatically Operated Dose Valve for component aLocation Intrinsically Safe Installation RequirementsLocation Requirements Optional CablesRequirements on NON-HAZARDOUS Hazardous Classified Location Location onlySee Dimensions and Mounting Hole Layouts, General InformationWall Mounting ProControl 1KS System Layout Drawing Wall Mounting Air Supply See the System Pneumatic Schematic onRequirements Air Connections Fluid Connections Fluid SupplyColor Change Valve Stack TI11668a Color Change Board and Solenoid ValvesFlow Control Regulator Regulator Fluid Air Fluid Out FC CableElectrical Requirements Connect Main PowerConnect EasyKey to Fluid Station Control EasyKey Connections and AC Power SwitchFluid Station Board Connections Color Change Board Switch Settings Two Color Change Boards Connect Color Change ModuleOne Color Change Board Switch S3-S6 J11 IG . Color Change Board Switches S3-S6Positions Wiring Diagram Check Resistance GroundingRobot EasyKey Display Control BoxSystem Pneumatic Schematic Schematic DiagramsNon-Hazardous Area System Electrical SchematicHazardous Area Wall Panel Mounting bracket only Dimensions and Mounting Hole LayoutsFlow Control Module Air Supply Control EasyKeyDimensions and Mounting Hole Layouts Maximum fluid working pressure Maximum working air pressure Technical DataGraco Information Graco Standard Warranty