Technical Data

Technical Data

Maximum fluid working pressure . . . . . . . . . . . . . . .

Maximum working air pressure. . . . . . . . . . . . . . . . .

Air supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Air filter inlet size . . . . . . . . . . . . . . . . . . . . . . . . . . .

Air filtration for air logic and purge air (Graco-supplied). . . . . . . . . . . . . . . . . . . . . . . . . . . .

Air filtration for atomizing air (user-supplied) . . . . . .

Fluids handled . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Viscosity range of fluid . . . . . . . . . . . . . . . . . . . . . . .

Fluid filtration (user-supplied) . . . . . . . . . . . . . . . . . .

Fluid flow rate range* G3000, G250 Meter G3000HR, G250HR Meter Coriolis Meter

S3000 Solvent Meter (accessory) Fluid inlet sizes

Flow Meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Dose Valve/Color Valve Adapters . . . . . . . . . . .

Fluid outlet size (static mixer) . . . . . . . . . . . . . . . . . .

External Power Supply Requirements . . . . . . . . . . .

Operating temperature range . . . . . . . . . . . . . . . . . .

Environmental Conditions Rating . . . . . . . . . . . . . . .

Noise Level

Sound pressure level . . . . . . . . . . . . . . . . . . . . .

Sound power level . . . . . . . . . . . . . . . . . . . . . . .

Wetted parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Base system: 4000 psi (27.58 MPa, 275.8 bar)

Low pressure color change: 300 psi (2.07 MPa, 20.6 bar)

Coriolis meter: 2300 psi (15.86 MPa, 158.6 bar)

Flow control: 190 psi (1.31 MPa, 13.1 bar)

100 psi (0.7 MPa, 7 bar)

75 - 100 psi (0.5 - 0.7 MPa, 5.2 - 7 bar) 3/8 npt(f)

5 micron (minimum) filtration required; clean and dry air

30 micron (minimum) filtration required; clean and dry air one component:

solvent and waterborne paints

polyurethanes

epoxies

acid catalyzed varnishes

moisture sensitive isocyanates

20- 5000 cps*

100 mesh minimum

75 - 3800 cc/min. (0.02-1.00 gal./min.)

38 - 1900 cc/min. (0.01-0.50 gal./min.)

20 - 3800 cc/min. (0.005-1.00 gal./min.)

38 - 1900 cc/min. (0.01-0.50 gal./min.)

1/4 npt(f) 1/4 npt(f) 1/4 npt(f)

85 - 250 Vac, 50/60 Hz, 2 amps maximum draw 15 amp maximum circuit breaker required

8 to 14 AWG power supply wire gauge

41- 122° F (5-50° C)

indoor use, pollution degree (2), installation category II

below 70 dBA below 85 dBA

303, 304 SST, Tungsten carbide (with nickel binder), perfluoroelastomer; PTFE

*Dependent on programmed K-factor and application. The maximum allowable flow meter pulse frequency is 425 Hz (pulses/sec). For more detailed information on viscosities, flow rates, or mixing ratios, consult your Graco dis- tributor.

See individual component manuals for additional technical data.

3A1163A

35

Image 35
Contents II 2 G ProControl 1KSContents Equipment Approvals Related ManualsLabel Location on EasyKey System Configuration and Part NumbersModels Accessory FeatureFire and Explosion Hazard Skin Injection Hazard Toxic Fluid or Fumes Hazard Important Two-Component Material Information Component Identification and Definition Pneumatically Operated Dose Valve for component a Control Box Power Supply Cable PS Flow ControlAssembly FC Component Description Fluid Manifold FMOptional Cables Intrinsically Safe Installation RequirementsLocation Location RequirementsRequirements on NON-HAZARDOUS Hazardous Classified Location Location onlyWall Mounting See Dimensions and Mounting Hole Layouts,General Information ProControl 1KS System Layout Drawing Wall Mounting Air Connections See the System Pneumatic Schematic onAir Supply RequirementsFluid Connections Fluid SupplyColor Change Valve Stack TI11668a Color Change Board and Solenoid ValvesFlow Control Regulator Regulator Fluid Air Fluid Out FC CableElectrical Requirements Connect Main PowerConnect EasyKey to Fluid Station Control EasyKey Connections and AC Power SwitchFluid Station Board Connections One Color Change Board Color Change Board Switch Settings Two Color Change BoardsConnect Color Change Module Positions Switch S3-S6J11 IG . Color Change Board Switches S3-S6 Wiring Diagram Check Resistance GroundingRobot EasyKey Display Control BoxSystem Pneumatic Schematic Schematic DiagramsNon-Hazardous Area System Electrical SchematicHazardous Area Wall Panel Mounting bracket only Dimensions and Mounting Hole LayoutsFlow Control Module Air Supply Control EasyKeyDimensions and Mounting Hole Layouts Maximum fluid working pressure Maximum working air pressure Technical DataGraco Information Graco Standard Warranty