4.3Technical Data NT 10000 Model

Recommended solar generator output

DC Nominal input

Standby consumption

Night consumption

Injection starts from

Nominal voltage

UMPP voltage range

No-load voltage

Turn-on voltage

Turn-off voltage

Maximum current

Nominal current

Number of inlets

Maximum efficiency level

European efficiency level (weighted) HERIC® topology

AC Nominal output continuous operation Pn Maximum output Pp

Nominal frequency Grid voltage

Grid voltage tolerance range Nominal current per phase Max. current per phase Distortion factor with Pn Reactive power factor (cos phi) Current waveform

Solar Inverter NT 10000

7000–12000 Wp

11000 W

20W

< 0.3 W

7W

400V

350<= UMPP <= 750 V

850V

420V

340V

10A per MPP multitracking inlet

9A per MPP multitracking inlet

1per MPP multitracking inlet;

3altogether

96.4percent (with ventilator operation)

95.9percent (with ventilator operation)

yes

10000 W

10000 W

50Hz

400V

-20 to +15 percent 14.5 A

18.2 A

< 3 percent approx. 1 sine

158

Page 74
Image 74
Sunway user manual Technical Data NT 10000 Model, Solar Inverter NT