Modem types not recommended by Sunways are not necessarily guaranteed to work.

For the remote modem to automatically respond to an incoming call and open the line, it has to be initialised with the Sunways Monitor software prior to instal- lation. For this, please also observe the software instructions.

Interface Cables

Depending on the type of link, different types of interface cables are needed. They are available from your Solar Inverter dea- ler. For further suppliers, please visit our website ww.sunways.de.

using products made by ICP Germany to ensure a reliable data transfer

To connect the interface transformer to a COM port (RS232) of your PC, use the «I-7520» model; to connect it to a USB-port of your PC, use the «I-7561» model. This accessory is available from your Solar Inverter dealer. For further suppliers, plea- se visit our website ww.sunways.de.

￿!

To set up the RS485 communication bet- ween the Solar Inverters properly, the RS485 addresses have to be set consecuti- vely, starting with address 01 (see chapter «Setting the RS485 Address»).

Interface Transformer

If you wish to read out the Solar Inverter data with your PC via the RS485 interface, you need an interface transformer to transform the RS485 signals into PC-compa- tible RS232 signals. We recommend .

132

Page 48
Image 48
Sunway NT 10000 user manual Interface Cables, Interface Transformer