Modem types not recommended by
Sunways are not necessarily guaranteed
to work.
For the remote modem to automatically
respond to an incoming call and open the
line, it has to be initialised with the
Sunways Monitor software prior to instal-
lation. For this, please also observe the
software instructions.
Interface Cables
Depending on the type of link, different
types of interface cables are needed. They
are available from your Solar Inverter dea-
ler. For further suppliers, please visit our
website ww.sunways.de.
Interface Transformer
If you wish to read out the Solar Inverter
data with your PC via the RS485 interface,
you need an interface transformer to
transform the RS485 signals into PC-compa-
tible RS232 signals. We recommend .
!using products made by ICP Germany to
ensure a reliable data transfer
To connect the interface transformer to a
COM port (RS232) of your PC, use the
«I-7520» model; to connect it to a USB-port
of your PC, use the «I-7561» model. This
accessory is available from your Solar
Inverter dealer. For further suppliers, plea-
se visit our website ww.sunways.de.
To set up the RS485 communication bet-
ween the Solar Inverters properly, the
RS485 addresses have to be set consecuti-
vely, starting with address 01 (see chapter
«Setting the RS485 Address»).
!
132
BP13370_NT_10000_englisch 23.11.2005 17:40 Uhr Seite 48