Error

Causes

Remedies

Error 027

The grid voltage is too high.

Grid overvoltage

The Solar Inverter monitors

3-phase

the lower and upper admis-

 

sible grid voltage limits in

 

3-phases. If the voltage

 

exceeds the upper limit

 

(Umax = 264 V), the Solar

 

Inverter will automatically

 

switch off and will only

 

restart when the voltage

 

value drops below the

 

upper limit again. The shut-

 

down can already be trig-

 

gered if the voltage rises

 

above the upper limit for

 

a short time.

Ask your power supply company about the stability and design of the grid.

Errors 028 to 030 The Solar Inverter has detec-

Surge fault ted a high voltage peak in the injecting phase.

The Solar Inverter will automatically restart when the error has been elimina- ted. Should the error occur often, please consult your power supply company.

149

Page 65
Image 65
Sunway NT 10000 user manual Error Causes