former Solar Inverter to your new one. You can either take over the total yield of the device, or the individual yield of each energy unit. If you set the total yield of the device, it will automatically be split among the energy units 1 to 3 in equal shares.
If you change the yield of the individual energy units separately, they will be added up to the total yield.
To do so, select the menu item «change settings» / «total yield». Here, you can select the total yield, energy unit 1, energy unit 2, or energy unit 3. To start changing the displayed value, press the RIGHT arrow key.
3.3Internal Data Memory
Your Solar Inverter is equipped with an internal data memory as a standard fea- ture. With the enclosed software Sunways Monitor, you can access these data. These Solar Inverter data will give you detailed information on the functioning method and relevant values of your solar energy supply at any time. The measured values
are stored in a ring buffer that automati- GB cally overwrites the earliest values with
the latest ones. The following measured values are stored in your Solar Inverter NT 10000:
15 minutes average values (500 data records, each with date/time):
·DC current
·DC voltage
·AC current
·AC voltage
·injected power
·insolation (optional)
·module temperature (optional)
129