2.2Basic Settings

Setting the Fixed Voltage Level

Your Sunways Solar Inverter is equipped with a precise MPP control. If less than 200 watt are injected, the control of the energy unit concerned operates at a fixed voltage level. That prevents unnecessary MPP searching. To minimise adjustment losses during fixed voltage operation, the fixed voltage level of each energy unit of the Solar Inverter can be set separately. The optimum fixed voltage level depends on your PV generator model.

«420 V» position

«540 V» position

GB

Fixed voltage level

420V

540V

No-load voltage

PV generator at 25 °C

630 V > 630 V

Illustr.: Slide switch «S100» for setting the fixed voltage level

The fixed voltage can be set with the slide switch «S100» on the control circuit board. Ex works, the switch is set to «420V».

To set a fixed voltage of 540 V, slide the switch to the «540V» position.

103

Page 19
Image 19
Sunway NT 10000 user manual Basic Settings, Fixed voltage level 420 540