With Tyco Solarlok connectors, different

1.

Bare the de-energised line by 8 mm

 

kinds of annular contacts are used for dif-

 

 

 

ferent conductor cross-sections. Make sure

2.

Crimp the annular contact

 

to use the right tools for these cross-sec-

 

 

 

tions. The enclosed Tyco Solarlok connec-

3. Slide the gland, the compression sleeve,

 

tors are equipped with annular contacts

 

and the seal onto the line

 

for a cable cross-section of 4 mm. The

 

 

 

enclosed seals have an internal diameter of

4.

Engage the contact in the connector

 

6 mm (for lines with a cladding diameter

 

housing

 

of 5.3 to 6.2 mm) and 8 mm (for lines with

 

 

 

 

 

GB

a cladding diameter of 7.2 to 8.0 mm).

5.

Screw the lock nut on

Make sure to use a seal that fits the clad-

 

 

 

ding diameter of the cable used.

6.

Tightening torque for the cable gland:

 

 

 

1.5 Nm

 

When installing the Tyco Solarlok connec-

 

 

 

tors, proceed in the following order:

 

 

 