Siemens SAMMS-MV user manual Contents

Page 3

Contents

1

Introduction

2

1.1

About this Manual

3

1.2 About the SAMMS-MV Device

3

 

1.2.1 The SAMMS-MV Device Models

4

 

1.2.2

Advanced Protection for Medium-Voltage

 

 

Motors

4

 

1.2.3

Overload Protection

5

 

1.2.4

Programming Control Circuits

5

 

1.2.5 Using the Standardized Control Panel ....

5

2

Installing the SAMMS-MV Device

7

2.1Receiving and Storing the SAMMS-MV Device . 7

2.2

Where to Locate the Device

7

2.3

Mounting the Device

7

2.4

Connecting the Device

7

 

2.4.1

Wiring Guidelines

7

 

2.4.2

Grounding the Device

9

 

2.4.3

Connecting the Device to a Control Power

 

 

Source

9

 

2.4.4

Connecting Input and Output Devices to

 

 

 

the SAMMS-MV Device

9

 

2.4.5

Communications Connection

9

3

Operating the SAMMS-MV Device

11

3.1

Password Protection

11

3.2

Using the Reset/Test Push Button

11

 

3.2.1 Performing a Lamp Test

11

 

3.2.2 Performing an Overload Relay Test

11

3.3

Motor Control

11

3.4

Output Devices

12

3.5

Input Devices

12

3.6

Ladder Diagrams

13

 

3.6.1 Library of Standard Ladder Diagrams ...

13

 

3.6.2 Custom Ladder Diagrams

13

3.7

Incomplete Sequence

17

3.8

Intelligent Reduced-Voltage

 

 

Starting (SAMMS-MVX Only)

17

3.9Ridethrough Upon Loss of Power

 

(SAMMS-MVX Only)

17

3.10

Overload Protection

17

3.11

Motor Ambient Temperature

17

3.12

Protection Curves and Overload

 

 

Classes

19

3.13

Ultimate Trip Level and Service Factor

23

3.14

Phase Unbalance

23

3.15

Dual Overload Protection

23

3.16

Jam Protection (SAMMS-MVX Only)

23

3.17

Loss of Load Protection/Warning

 

 

(SAMMS-MVX Only)

23

3.18

Process Current Warning (SAMMS-MVX Only) 23

3.19

Stator Protection

23

3.20

Rotor Protection

23

3.21

Repetitive Starts

24

3.22

Start Inhibit

24

3.23

Cooling Time Constants

24

3.24

Normalized Temperature Rise for Class B and

 

 

Class F Insulation

24

3.25

Ground Fault Detection

24

3.26

Autoreset After a Trip (SAMMS-MVX Only)

26

3.27

Emergency Restarting

26

3.28

Using the Hand Held Communicator (HHC) ...

26

 

3.28.1The (F)unction Key

26

 

3.28.2The LIST Key

26

 

3.28.3UP and DOWN Keys

28

 

3.28.4Using the ENTER Key

28

3.29

Using the SAMMS-MV Device

 

 

Functions

28

 

3.29.1Program Mode/Passwords

32

 

3.29.2 SAMMS-MV Functions

32

4

Troubleshooting the SAMMS-MV

 

 

Device

40

Appendix A - Technical Specifications of the

 

SAMMS-MV Device

43

©Copyright 1994 Siemens Energy & Automation, Inc.

ACCESS, SAMMS, SAMMS-MV, Series 81000, SEAbus, Power Monitor, Power Monitor PC, WinPM, and SIEServe are trademarks of Siemens Energy & Automation, Inc. Microsoft is a registered trademark and Windows is a trademark of Microsoft Corporation. IBM is a registered trademark of International Business Machines, Inc.

1

Image 3
Contents SAMMS-MV Qualified Person Contents Signal Words Field Service OperationQualified Person About this Manual Advanced Protection for Medium-Voltage Motors SAMMS-MV Device ModelsUsing the Standardized Control Panel Overload ProtectionProgramming Control Circuits Light bars Change settings requires password Yes Remote inputs OneSAMMS-MV Model Outputs OneInstalling the SAMMS-MV Device Full voltage non-reversing connection diagram Grounding the Device SAMMS-MV device communications connections Performing an Overload Relay Test Password ProtectionUsing the Reset/Test Push Button Performing a Lamp TestInput Devices Output DevicesCustom Ladder Diagrams Ladder Diagrams Library of Standard Ladder DiagramsSAMMS-MVX Standard control circuits PB1 PB2 PB3 PB4 PB5 PB6 Intelligent Reduced-Voltage Starting SAMMS-MVX Only Ridethrough Upon Loss of Power SAMMS-MVX OnlyMotor Ambient Temperature Incomplete SequenceODP motor thermal signature Protection Curves and Overload Classes Seconds Operating the SAMMS-MV 11 Motor protection graph Jam Protection SAMMS-MVX Only Ultimate Trip Level and Service FactorPhase Unbalance Dual Overload Protection SAMMS-MVX OnlyCooling Time Constants Ground Fault DetectionRepetitive Starts Start Inhibit12 Multi-start scenario for an ODP motor Function Key Autoreset After a Trip SAMMS-MVX OnlyUsing the Hand Held Communicator HHC Emergency RestartingMotor type Overload trip class class 2 through 5A CT primary current low speed if used Service factorFunction Number 5A CT primary current if used Full load current for OLR NoUsing the Enter Key Using the SAMMS-MV Device Func- tionsUP and Down Keys ON/OFF Select jam pickup current 120-400% Iflc F24 Loss of Load Select ground fault pick-up currentDefault Value Means warning13 Entering and changing passwords F1 Control Circuit Number and Incomplete Se- quence Status Program Mode/PasswordsF0 Ambient Temperature SAMMS-MV Functions18 to 72A Overload Setting Step Default Relay Size RangeF3 Size for Overload Relay #2 SAMMS-MVX Only F4 Full-Load Current for Overload Relay #1F7A Cold Stall Time F6 Service FactorF6A Motor Type F7 Overload Trip ClassF11 Emergency Restarting F8 Autoreset SAMMS-MVX OnlyF9 Phase Unbalance Protection F10 Display Time to RestartF13 Set Programmable Timer #1 F12 Ground Fault Protection or WarningF12A Ground Fault Pickup Current Size Pickup Current Default H3A-H3C 7A-I FLC 10A 20AF18 Display Total Elapsed Run Time of the Motor F21 Reset Motor DataF16 Trip Current F17 Current UnbalanceF23A Jam Pickup Current SAMMS-MVX Only F25 Percentage of Motor Winding TemperatureF22 Process Current Warning Level SAMMS-MVX Only F23 Jam Protection SAMMS-MVX OnlyF27 Address F26 Baud RateTroubleshooting Error Condition Troubleshooting Guide Error Condition Appendix a Technical Specifications Over load Spec ificat ions Stat ist ica l Data Dimensions Catalog Number SAM6 Switch # Function Position 375 Siemens Energy Automation, Inc