Siemens SAMMS-MV user manual About this Manual

Page 5

1 Introduction

1.1 About this Manual

This manual introduces you to the Siemens Advanced Motor Master System (SAMMS-MVä) motor protection and control relay which incorporates protection designed for medium voltage machines. This manual also contains information for installing and operating the device, communicating with other devices over the ACCESSä electrical distribution communica- tions system, and troubleshooting the device. This manual also provides a helpful technical reference for you to use. Refer to table 1.1 to determine which section of the manual contains the information that you need.

These instructions prepare you to handle, install, operate and maintain the SAMMS-MV device and the Hand-Held Commu- nicator (HHC). The individual starters and controllers used are designed for specific applications based upon your equipment and needs. Instructions covering these starters and compo- nents are not included in this manual. For this information, refer to instructions and drawings furnished with your equipment, or contact your Siemens representative. You must read these instructions and determine applicability of your equipment. Refer to the nameplate data on your controller and to the electrical diagrams supplied with your controller to determine applicability of your equipment.

1.2 About the SAMMS-MV Device

The SAMMS-MV device, shown in Figure 1.1, is a software- configured electronic motor control and overload protection device that incorporates protection tailored to the special characteristics of medium voltage motors. The SAMMS-MV system includes a microprocessor-based SAMMS-MV device which receives signal inputs from a set of current transformers (either 3-1Ø or 1-3Ø) and power input from a 12 volt tap on the controller’s control power transformer. To perform certain monitoring and setup activities, a Hand-Held Communicator (HHC) shown in Figure 1.2, is required. The SAMMS-MV device is a multi-functional device offering the following:

advanced motor protection for medium voltage motors

pre-programmed control circuits

standardized control panel with input/output devices replac- ing conventional push-buttons, pilot lights and selector switches

diagnostics

statistical motor data

real-time metering

local display of all motor and control circuit data

open architecture communications using the ACCESS sys- tem

Note: The SAMMS-MV device does not replace the disconnect device (drawout contactor mounting or isolating switch) or the contactor itself.

If you need to...

...refer to this section

 

 

learn about the SAMMS-MV device

Section 1, Introduction

 

 

install the SAMMS-MV device

Section 2, Installing the SAMMS-MV Device

 

 

operate the SAMMS-MV device

Section 3, Operating the SAMMS-MV Device

 

 

operate the Hand-Held Communicator

Section 3, Operating the SAMMS-MV Device

 

 

connect the SAMMS-MV device to the ACCESS

Section 2, Installing the SAMMS-MV Device

System

 

 

 

troubleshoot the SAMMS-MV device

Section 4, Troubleshooting the SAMMS-MV Device

 

 

learn about the technical specifications of the

Appendix A, Technical Specifications of the SAMMS-MV Device

SAMMS-MV device

 

 

 

Table 1.1 Where to find information

 

3

Image 5
Contents SAMMS-MV Qualified Person Contents Qualified Person Signal WordsField Service Operation About this Manual Advanced Protection for Medium-Voltage Motors SAMMS-MV Device ModelsProgramming Control Circuits Using the Standardized Control PanelOverload Protection SAMMS-MV Model Change settings requires password Yes Remote inputs OneOutputs One Light barsInstalling the SAMMS-MV Device Full voltage non-reversing connection diagram Grounding the Device SAMMS-MV device communications connections Using the Reset/Test Push Button Password ProtectionPerforming a Lamp Test Performing an Overload Relay TestInput Devices Output DevicesCustom Ladder Diagrams Ladder Diagrams Library of Standard Ladder DiagramsSAMMS-MVX Standard control circuits PB1 PB2 PB3 PB4 PB5 PB6 Motor Ambient Temperature Ridethrough Upon Loss of Power SAMMS-MVX OnlyIncomplete Sequence Intelligent Reduced-Voltage Starting SAMMS-MVX OnlyODP motor thermal signature Protection Curves and Overload Classes Seconds Operating the SAMMS-MV 11 Motor protection graph Phase Unbalance Ultimate Trip Level and Service FactorDual Overload Protection SAMMS-MVX Only Jam Protection SAMMS-MVX OnlyRepetitive Starts Ground Fault DetectionStart Inhibit Cooling Time Constants12 Multi-start scenario for an ODP motor Using the Hand Held Communicator HHC Autoreset After a Trip SAMMS-MVX OnlyEmergency Restarting Function KeyFunction Number 5A CT primary current low speed if used Service factor5A CT primary current if used Full load current for OLR No Motor type Overload trip class class 2 throughUP and Down Keys Using the Enter KeyUsing the SAMMS-MV Device Func- tions ON/OFF Default Value Select ground fault pick-up currentMeans warning Select jam pickup current 120-400% Iflc F24 Loss of Load13 Entering and changing passwords F0 Ambient Temperature Program Mode/PasswordsSAMMS-MV Functions F1 Control Circuit Number and Incomplete Se- quence StatusF3 Size for Overload Relay #2 SAMMS-MVX Only Overload Setting Step Default Relay Size RangeF4 Full-Load Current for Overload Relay #1 18 to 72AF6A Motor Type F6 Service FactorF7 Overload Trip Class F7A Cold Stall TimeF9 Phase Unbalance Protection F8 Autoreset SAMMS-MVX OnlyF10 Display Time to Restart F11 Emergency RestartingF12A Ground Fault Pickup Current F12 Ground Fault Protection or WarningSize Pickup Current Default H3A-H3C 7A-I FLC 10A 20A F13 Set Programmable Timer #1F16 Trip Current F21 Reset Motor DataF17 Current Unbalance F18 Display Total Elapsed Run Time of the MotorF22 Process Current Warning Level SAMMS-MVX Only F25 Percentage of Motor Winding TemperatureF23 Jam Protection SAMMS-MVX Only F23A Jam Pickup Current SAMMS-MVX OnlyF27 Address F26 Baud RateTroubleshooting Error Condition Troubleshooting Guide Error Condition Appendix a Technical Specifications Over load Spec ificat ions Stat ist ica l Data Dimensions Catalog Number SAM6 Switch # Function Position 375 Siemens Energy Automation, Inc