Presario 1800 Series

Models: XL180, XL181, XL182, XL183, XL184, XL185,

and XL190, XL191, XL192

 

 

Audio Test Error Codes

Error Code

Description

 

Recommended Action

 

 

 

 

 

3206-xx

Audio System Internal Error

Replace the system board and retest.

TouchPad Interface Test Error Codes

Error Code Description

Recommended Action

8601-xx

8602-xx

Mouse test failed

Interface test failed

1.Replace the TouchPad and retest.

2.Replace the system board and retest.

DVD or CD Drive Test Error Codes

Error Code Description

Recommended Action

3301-xx

3305-xx

6600-xx

6605-xx

6608-xx

6623-xx

DVD or CD drive read test failed

DVD or CD drive seek test failed

ID test failed

Read test failed

Controller test failed

Random read test failed

1.Replace the DVD or CD media and retest.

2.Verify that the speakers are connected.

3.Verify that drivers are loaded and properly installed.

4.Replace the CD/DVD drive and retest.

5.Replace the system board and retest.

PRESARIO NOTEBOOK MAINTENANCE AND SERVICE GUIDE 1800 SERIES

TROUBLESHOOTING 17

Page 53
Image 53
Compaq XL181, XL190, XL180, XL191, XL192, XL183, XL185, XL182 Audio Test Error Codes, Error Code Description Recommended Action