Presario 1800 Series
Models: XL180, XL181, XL182, XL183, XL184, XL185,
and XL190, XL191, XL192
|
| Audio Test Error Codes | |
Error Code | Description |
| Recommended Action |
| |||
|
|
|
|
Audio System Internal Error
Replace the system board and retest.
TouchPad Interface Test Error Codes
Error Code Description | Recommended Action |
Mouse test failed
Interface test failed
1.Replace the TouchPad and retest.
2.Replace the system board and retest.
DVD or CD Drive Test Error Codes
Error Code Description | Recommended Action |
DVD or CD drive read test failed
DVD or CD drive seek test failed
ID test failed
Read test failed
Controller test failed
Random read test failed
1.Replace the DVD or CD media and retest.
2.Verify that the speakers are connected.
3.Verify that drivers are loaded and properly installed.
4.Replace the CD/DVD drive and retest.
5.Replace the system board and retest.
PRESARIO NOTEBOOK MAINTENANCE AND SERVICE GUIDE 1800 SERIES | TROUBLESHOOTING 17 |