Furuno FSV-24S installation manual Language

Page 59

LANGUAGE

Select the language. (JAPANESE, ENGLISH)

HEADING ADJUST

See “3.2 Heading Adjustment”.

ES2 SELECT

Select the equipment connected to the ES2 port among echosounder and net recorder. (ES, NET REC)

ES DRAFT OFFSET

When connecting echosounder, set the ship’s draft line to use depth from draft rather than depth from transducer. (0.0 m to 10.0 m, 0.1 m steps)

EVENT KEY

Select the key for entering own ship’s position, EVENT or SHOOT. When selecting SHOOT, the shoot function is not available. (EVENT, SHOOT)

AUTO TILT

Select the range for the auto tilt, WIDE (±2 to 10°, ±4 to 16°, ±6 to 20°) or NARROW (±1 to 4°, ±2 to 6°, ±3 to 8°). (WIDE, NARROW)

SELECT USER PROG

Select whether to program horizontal and vertical displays together or individually, by the USER PROG control. H/V INTERLOCK, the default setting, commonly applies control settings to the horizontal and vertical displays. H/V INDVIDUAL enables individual adjustment.

TRACKBALL SPEED

Select the speed of trackball movement (inside menu window only). (SLOW,

NORMAL, FAST)

HULL UNIT STROKE

Select the stroke length of the hull unit. (1200 mm, 1600 mm).

3-11

Image 59
Contents Check List Iii00080916714 Safety Instructions Projected Raising Lowering Mm stroke Max kt Standard type System ConfigurationControl Unit Black box typeStandard supply Equipment ListsSEM-21Q OptionsLocation of hull unit Mounting the Hull UnitMaintenance space, example sonar compartment Shortening the retraction tank Retraction tank Reinforcement rib 250-300 mm Remarks for installation of retraction tankInstalling hull unit on retraction tank Installation of hull unit Bow Stay Hull Unit Installing stays anti-vibration measureProcessor unit Mounting the Display UnitMonitor unit Mounting procedureMonitor unit Attaching the CRT filter Control unitFixing without KB fixing plate KB fixing plate Mounting the Transceiver Unit Mounting the Power Supply UnitGrounding the Equipment Procedure Page Mounting the Cable for Extension Kit option Attachment Kit option Using the optional attachment kit How to use the pin extractor How to Use the Crimping Tool, Pin ExtractorHow to use the crimping tool Local supply Location of ConnectorsTransceiver unit side Fabrication of monitor cable 10S2074 10 m/10S2075 30 m Monitor UnitPositioning guide pins Control cable Assembling D-SUB connector CN-A302How to connect cables to the monitor unit 1 10S1258-1 cable Processor UnitPower cable Monitor cable 10S2074 or 10S2075 Optional equipment Schematic view of cablesGyro Processor EXT-KPunit Transceiver Unit Fabrication of connector 00-8016-038-313761HV CN-B101Hull control cable 10S2078 Fabrication of power cable type DPYCY-4 TB-B101Connection Junction box Power Supply UnitCable for Extension Kit Cable clamp CKS clamp Raise/Lower Control Box Power cable fabrication Adjustment and Check Test Menu OFF Heading adjustment Heading AdjustmentSystem menu OWN Ship Mark menu Configuring Own Ship MarkTD Position Other System Menu Items Interface Setting menuSpeed & Course EXT Data Setting menuWind Others menuLanguage Adjusting the volume of audio alarm Cone Board Setting in the Processor UnitAdjustment of signal level echo sounder connected 1 CIF2/NMEA2 connector interface selection DIP Switch SettingSelecting the Net Sonde information Selecting echosounder signalTesting TX/RX independently at hull unit This page is intentionally left blank Connecting the External Interface CS-120A VH4P PP GND Ciftxdh Ciftxdc Cifrxdh Cifrxdc Shield Check List Data Sheet Data Sheet Dispaly Unit FSV-2400 User menu Color response curve sheet H 工事材料表 006-921-240-00 10CO-X-9402 006-921-250-00 10CO-X-9403 10CO-X-9412 Page 10CO-X-9406 10CO-X-9410 Furuno Electric CO .,LTD C1318-M10-C 付属品表 Page Page Page 000-144-382-00 000-155-839-10 000-157-497-10 Page Page Page Page Page Page Jan Jan Hatai Hatai Page Page Page Color Scanning Sonar Title FSV-24/24S Miyosi 制御部