3.6.2Selecting the Net Sonde information

The net depth information from the Net Sonde can be entered from the FNZ port or CIF port. Depending on the input port, select the DIP switch setting as follows. The default setting is FNZ.

Input port

DIP switch S3 - #1

FNZ(default)

OFF

CIF1 or NMEA2/CIF2

ON

S3

DCON Board (10P6900 or 10P6900S)

Note1: When the NMEA2/CIF2 port is used, the DIP switch S2-#8 on the IFES board should be OFF. See page 3-13.

Note2: Do not change the setting of S3-#4 (default: OFF). The hull unit may be damaged if the setting is changed.

3.6.3Selecting echosounder signal

There are two kinds of echosounder signals, AC signal and DC signal. Depending on the signal, select the jumper setting at J496 and J497 on the CONE board as follows. The default setting is AC. See page 3-13 for parts location.

Input port

Jumper

ES1

J497

ES2/NET

J496

Note: SIGOUT (AC signal) terminal and REC terminal (DC signal) in the output port are provided for FURUNO echosounder. Therefore, when using SIGOUT terminal, it is not necessary to change jumper setting.

3-14

Image 62
Contents Iii Check List00080916714 Safety Instructions Projected Raising Lowering Mm stroke Max kt System Configuration Standard typeBlack box type Control UnitEquipment Lists Standard supplyOptions SEM-21QMounting the Hull Unit Location of hull unitMaintenance space, example sonar compartment Shortening the retraction tank Remarks for installation of retraction tank Retraction tank Reinforcement rib 250-300 mmInstalling hull unit on retraction tank Installation of hull unit Installing stays anti-vibration measure Bow Stay Hull UnitMounting the Display Unit Processor unitMounting procedure Monitor unitMonitor unit Control unit Attaching the CRT filterFixing without KB fixing plate KB fixing plate Mounting the Power Supply Unit Mounting the Transceiver UnitGrounding the Equipment Procedure Page Mounting the Cable for Extension Kit option Attachment Kit option Using the optional attachment kit How to use the pin extractor How to Use the Crimping Tool, Pin ExtractorHow to use the crimping tool Location of Connectors Local supplyTransceiver unit side Monitor Unit Fabrication of monitor cable 10S2074 10 m/10S2075 30 mPositioning guide pins Assembling D-SUB connector CN-A302 Control cableHow to connect cables to the monitor unit Processor Unit 1 10S1258-1 cablePower cable Monitor cable 10S2074 or 10S2075 Schematic view of cables Optional equipmentGyro Processor EXT-KPunit Fabrication of connector 00-8016-038-313761HV CN-B101 Transceiver UnitFabrication of power cable type DPYCY-4 TB-B101 Hull control cable 10S2078Connection Junction box Power Supply UnitCable for Extension Kit Cable clamp CKS clamp Raise/Lower Control Box Power cable fabrication Adjustment and Check Test Menu OFF Heading Adjustment Heading adjustmentSystem menu Configuring Own Ship Mark OWN Ship Mark menuTD Position Interface Setting menu Other System Menu ItemsEXT Data Setting menu Speed & CourseOthers menu WindLanguage Adjusting the volume of audio alarm Cone Board Setting in the Processor UnitAdjustment of signal level echo sounder connected DIP Switch Setting 1 CIF2/NMEA2 connector interface selectionSelecting echosounder signal Selecting the Net Sonde informationTesting TX/RX independently at hull unit This page is intentionally left blank Connecting the External Interface CS-120A VH4P PP GND Ciftxdh Ciftxdc Cifrxdh Cifrxdc Shield Check List Data Sheet Data Sheet Dispaly Unit FSV-2400 User menu Color response curve sheet H 工事材料表 006-921-240-00 10CO-X-9402 006-921-250-00 10CO-X-9403 10CO-X-9412 Page 10CO-X-9406 10CO-X-9410 Furuno Electric CO .,LTD C1318-M10-C 付属品表 Page Page Page 000-144-382-00 000-155-839-10 000-157-497-10 Page Page Page Page Page Page Jan Jan Hatai Hatai Page Page Page Color Scanning Sonar Title FSV-24/24S Miyosi 制御部