8.Rotate the [ENTER] knob to set digit and push the [ENTER] knob. To clear a line of data, press the [CLR FLD] soft key (one of the keys below the screen).
Setting range
Draft setup:
Speed calibration:
Temp calibration:
Acoustic speed calibration:
9.Set other digits as you did in step 8.
10.Press the [SAVE] soft key (one of the keys below the screen). 11.If necessary, follow steps
12.Press the [MENU] key to close all open windows and erase the menu bar.
3.4Choosing Data Source(s)
Choose the source of depth, water temperature and speed data as follows:
1.Press the [MENU] key to show the menu bar.
2.Rotate the [ENTER] knob to choose ADVANCED on the menu bar and then push the [ENTER] knob.
3.Rotate the [ENTER] knob to choose INPUT/OUTPUT and then push the [ENTER] knob.
4.Rotate the [ENTER] knob to choose DEPTH SOURCE, TEMP SOURCE or STW SOURCE (speed) depending on your system configuration and then push the [ENTER] knob.
NMEA
Sounder
5.Rotate the [ENTER] knob to choose NMEA or Sounder as appropriate and then push the [ENTER] knob. Choose Sounder if you wish to use
6.Press W to close the window.
7.If applicable, repeat steps 4 thru 6 to choose other data sources.
8.Press the [MENU] key to close all open windows and erase the menu bar.
Note:The following data sentences are required to display respective data. Depth: DPT (Ver. 2.0)
or DBT (Ver. 1.5), Temperature: MTW, and STW (Speed Thru Water): VTG, RMC or RMA.
32